These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

119 related articles for article (PubMed ID: 2516106)

  • 1. A comparative experimental investigation in monkeys between three different implant materials.
    Nordlund A; Zetterqvist L; Odén A
    Int J Oral Maxillofac Surg; 1989 Dec; 18(6):373-7. PubMed ID: 2516106
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Loaded custom-made zirconia and titanium implants show similar osseointegration: an animal experiment.
    Kohal RJ; Weng D; Bächle M; Strub JR
    J Periodontol; 2004 Sep; 75(9):1262-8. PubMed ID: 15515343
    [TBL] [Abstract][Full Text] [Related]  

  • 3. X-ray microanalytical and morphological observations of the interface region between ceramic implant and bone.
    Zetterqvist L; Anneroth G; Nordenram A; Wroblewski R
    Clin Oral Implants Res; 1995 Jun; 6(2):104-13. PubMed ID: 7578780
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Tissue integration of Al2O3-ceramic dental implants: an experimental study in monkeys.
    Zetterqvist L; Anneroth G; Nordenram A
    Int J Oral Maxillofac Implants; 1991; 6(3):285-93. PubMed ID: 1813397
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Enhanced osteoporotic effect of silicon carbide nanoparticles combine with nano-hydroxyapatite coated anodized titanium implant on healthy bone regeneration in femoral fracture.
    Li T; Li XL; Hu SX; Wu J
    J Photochem Photobiol B; 2019 Aug; 197():111515. PubMed ID: 31255939
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Residual aluminum oxide on the surface of titanium implants has no effect on osseointegration.
    Piattelli A; Degidi M; Paolantonio M; Mangano C; Scarano A
    Biomaterials; 2003 Oct; 24(22):4081-9. PubMed ID: 12834604
    [TBL] [Abstract][Full Text] [Related]  

  • 7. A comparison of biocompatibility and osseointegration of ceramic and titanium implants: an in vivo and in vitro study.
    Möller B; Terheyden H; Açil Y; Purcz NM; Hertrampf K; Tabakov A; Behrens E; Wiltfang J
    Int J Oral Maxillofac Surg; 2012 May; 41(5):638-45. PubMed ID: 22406235
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Hard and soft tissue responses to implant made of three different materials with microgrooved collar in a dog model.
    Igarashi K; Nakahara K; Kobayashi E; Watanabe F; Haga-Tsujimura M
    Dent Mater J; 2018 Nov; 37(6):964-972. PubMed ID: 29998938
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Osteogenesis and morphology of the peri-implant bone facing dental implants.
    Franchi M; Orsini E; Trire A; Quaranta M; Martini D; Piccari GG; Ruggeri A; Ottani V
    ScientificWorldJournal; 2004 Dec; 4():1083-95. PubMed ID: 15632988
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Collagen fiber orientation around machined titanium and zirconia dental implant necks: an animal study.
    Tetè S; Mastrangelo F; Bianchi A; Zizzari V; Scarano A
    Int J Oral Maxillofac Implants; 2009; 24(1):52-8. PubMed ID: 19344025
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Mechanical properties of bone tissues surrounding dental implant systems with different treatments and healing periods.
    Kim DG; Kwon HJ; Jeong YH; Kosel E; Lee DJ; Han JS; Kim HL; Kim DJ
    Clin Oral Investig; 2016 Nov; 20(8):2211-2220. PubMed ID: 26832783
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Osseointegration of Zirconia in the Presence of Multinucleated Giant Cells.
    Chappuis V; Cavusoglu Y; Gruber R; Kuchler U; Buser D; Bosshardt DD
    Clin Implant Dent Relat Res; 2016 Aug; 18(4):686-98. PubMed ID: 26377587
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Evaluation of alumina toughened zirconia implants with a sintered, moderately rough surface: An experiment in the rat.
    Kohal RJ; Bächle M; Renz A; Butz F
    Dent Mater; 2016 Jan; 32(1):65-72. PubMed ID: 26621027
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Cytocompatibility of two coating materials, amorphous alumina and silicon carbide, using human differentiated cell cultures.
    Naji A; Harmand MF
    Biomaterials; 1991 Sep; 12(7):690-4. PubMed ID: 1742414
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Analysis of failed commercially pure titanium dental implants: a scanning electron microscopy and energy-dispersive spectrometer x-ray study.
    Shibli JA; Marcantonio E; d'Avila S; Guastaldi AC; Marcantonio E
    J Periodontol; 2005 Jul; 76(7):1092-9. PubMed ID: 16018751
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Wear at the titanium-titanium and the titanium-zirconia implant-abutment interface: a comparative in vitro study.
    Stimmelmayr M; Edelhoff D; Güth JF; Erdelt K; Happe A; Beuer F
    Dent Mater; 2012 Dec; 28(12):1215-20. PubMed ID: 23021964
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Histologic and histomorphometric behavior of microgrooved zirconia dental implants with immediate loading.
    Delgado-Ruiz RA; Calvo-Guirado JL; Abboud M; Ramirez-Fernandez MP; Maté-Sánchez de Val JE; Negri B; Rothamel D
    Clin Implant Dent Relat Res; 2014 Dec; 16(6):856-72. PubMed ID: 23560416
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Comparison of surface modified zirconia implants with commercially available zirconium and titanium implants: a histological study in pigs.
    Gredes T; Kubasiewicz-Ross P; Gedrange T; Dominiak M; Kunert-Keil C
    Implant Dent; 2014 Aug; 23(4):502-7. PubMed ID: 25025856
    [TBL] [Abstract][Full Text] [Related]  

  • 19. [An experimental study of the tissue compatibility of titanium implants coated with hydroxyapatite and aluminum oxide by plasma spraying].
    Frolov AG; Triandafillidis S; Novikov SV; Fedorov SIu; Karasev MV; Tsimbalistov AV
    Stomatologiia (Mosk); 1995; 74(3):9-11. PubMed ID: 7570708
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Flexural strength of a glass-infiltrated alumina dental ceramic incorporated with silicon carbide whiskers.
    Tan SC; Chai J; Wozniak WT; Takahashi Y
    Int J Prosthodont; 2001; 14(4):350-4. PubMed ID: 11508091
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.