93 related articles for article (PubMed ID: 25163947)
1. Comparison of two pressurisers for cementation of the proximal femur.
Morishima T; Choy GG; Crawford RW; Wilson LJ
J Orthop Surg (Hong Kong); 2014 Aug; 22(2):163-7. PubMed ID: 25163947
[TBL] [Abstract][Full Text] [Related]
2. Modified femoral pressuriser generates a longer lasting high pressure during cement pressurisation.
Wang JS; Garellick G; Kjellson F; Tanner E; Flivik G
J Orthop Surg Res; 2011 Oct; 6():54. PubMed ID: 22004662
[TBL] [Abstract][Full Text] [Related]
3. Femoral cement pressurisation for hip arthroplasty in previously fixated hips: an experimental study.
McMahon SE; Alvi F; Lemon JG; Lovell ME
Injury; 2010 Apr; 41(4):352-5. PubMed ID: 19828147
[TBL] [Abstract][Full Text] [Related]
4. Cement restrictor function below the femoral isthmus.
Moran M; Heisel C; Rupp R; Simpson AH; Breusch SJ
Clin Orthop Relat Res; 2007 May; 458():111-6. PubMed ID: 17206103
[TBL] [Abstract][Full Text] [Related]
5. Enhancing proximal femoral pressure during cemented stem insertion.
Budnar VM; Bannister GC
Hip Int; 2012; 22(3):302-6. PubMed ID: 22740281
[TBL] [Abstract][Full Text] [Related]
6. [Initial stability of an implanted cement-canal prosthesis. Results in experimental studies on human cadaver femurs].
Jansson V; Zimmer M; Kühne JH; Sailer FP
Z Orthop Ihre Grenzgeb; 1993; 131(4):377-81. PubMed ID: 8212817
[TBL] [Abstract][Full Text] [Related]
7. Reducing the risk of bone cement implantation syndrome during femoral arthroplasty.
Rothberg DL; Kubiak EN; Peters CL; Randall RL; Aoki SK
Orthopedics; 2013 Apr; 36(4):e463-7. PubMed ID: 23590786
[TBL] [Abstract][Full Text] [Related]
8. Cement pressurisation in the acetabulum.
Wadia F; Malik MH; Leonard D; Porter ML
Int Orthop; 2006 Aug; 30(4):237-42. PubMed ID: 16639594
[TBL] [Abstract][Full Text] [Related]
9. An in-vitro investigation of the CPS-Plus femoral stem: influence of the proximal centraliser on cement pressurisation during stem insertion.
Gozzard C; Gheduzzi S; Miles AW; Learmonth ID
Acta Orthop Scand; 2003 Apr; 74(2):154-8. PubMed ID: 12807321
[TBL] [Abstract][Full Text] [Related]
10. Femoral cement pressurization in hip arthroplasty: a laboratory comparison of three techniques.
Kapoor B; Datir SP; Davis B; Wynn-Jones CH; Maffulli N
Acta Orthop Scand; 2004 Dec; 75(6):708-12. PubMed ID: 15762260
[TBL] [Abstract][Full Text] [Related]
11. Femoral cement pressurization in hip arthroplasty: a comparison of 3 systems.
Munro NA; Nicol M; Selvaraj S; Hussain SM; Finlayson DF
J Arthroplasty; 2007 Sep; 22(6):893-901. PubMed ID: 17826282
[TBL] [Abstract][Full Text] [Related]
12. [Air permeable diaphyseal obturators: efficacity of femoral cementing and prevention of associated cardiovascular disorders].
Caton J; Prudhon JL; Aslanian T; Lifante JC; Ritz B
Rev Chir Orthop Reparatrice Appar Mot; 2002 Dec; 88(8):767-76. PubMed ID: 12503018
[TBL] [Abstract][Full Text] [Related]
13. Assessment of cement introduction and pressurization techniques.
Dunne NJ; Orr JF; Beverland DE
Proc Inst Mech Eng H; 2004; 218(1):11-25. PubMed ID: 14982342
[TBL] [Abstract][Full Text] [Related]
14. The timing of femoral component insertion in cemented hip arthroplasty.
McWilliams TG; Binns MS
J Arthroplasty; 2003 Jan; 18(1):51-5. PubMed ID: 12555183
[TBL] [Abstract][Full Text] [Related]
15. In vitro performance of intramedullary cement restrictors in total hip arthroplasty.
Heisel C; Norman T; Rupp R; Pritsch M; Ewerbeck V; Breusch SJ
J Biomech; 2003 Jun; 36(6):835-43. PubMed ID: 12742451
[TBL] [Abstract][Full Text] [Related]
16. A cement fixation system for total hip arthroplasty.
Oh I; Harris WH
Clin Orthop Relat Res; 1982 Apr; (164):221-9. PubMed ID: 7067290
[TBL] [Abstract][Full Text] [Related]
17. A comparison of 2 modern femoral cementing techniques: analysis by cement-bone interface pressure measurements, computerized image analysis, and static mechanical testing.
Reading AD; McCaskie AW; Barnes MR; Gregg PJ
J Arthroplasty; 2000 Jun; 15(4):479-87. PubMed ID: 10884209
[TBL] [Abstract][Full Text] [Related]
18. A novel technique for femoral canal occlusion during cement pressurization in proximal femoral arthroplasty.
Holt G; Panousis K; Mohammed A; Patil S; Meek RM
J Arthroplasty; 2012 Jan; 27(1):129-33. PubMed ID: 22152980
[TBL] [Abstract][Full Text] [Related]
19. Choosing the optimum swab for canal drying in cemented total hip replacement.
Cutts S; Pasapula CS; Modi NR; Gwozdziewicz L; Bowers AG
Hip Int; 2011; 21(1):107-11. PubMed ID: 21279959
[TBL] [Abstract][Full Text] [Related]
20. [Stability and occlusion of six different femoral cement restrictors].
Heisel C; Norman TL; Rupp R; Mau H; Breusch SJ
Orthopade; 2003 Jun; 32(6):541-7. PubMed ID: 12819894
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]