BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

128 related articles for article (PubMed ID: 25167668)

  • 1. [The design and application of anterior cervical pedicle screw-plate system in lower cervical spine].
    Zhao LJ; Xu RM; Ma WH; Li J; Jiang WY; Song XH; Hua Q; Li GQ; Liu MX; Yu L
    Zhongguo Gu Shang; 2014 May; 27(5):390-4. PubMed ID: 25167668
    [TBL] [Abstract][Full Text] [Related]  

  • 2. [Comparison of statics characteristics between anterior transpedicular screws system and vertebral body screws system in lower cervical spine].
    Zhao LJ; Li J; Jiang WY; Xu RM; Ma WH; Qi F; Yu L; Zhang M; Wang YJ
    Zhongguo Gu Shang; 2014 Feb; 27(2):118-22. PubMed ID: 24826474
    [TBL] [Abstract][Full Text] [Related]  

  • 3. [Radiological studies on the best entry point and trajectory of anterior cervical pedicle screw in the lower cervical spine].
    Zhao LJ; Xu RM; Hua Q; Ma WH; Jiang WY; Zhu YZ
    Zhongguo Gu Shang; 2012 Dec; 25(12):1030-5. PubMed ID: 23627153
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Biomechanical comparison of two-level cervical locking posterior screw/rod and hook/rod techniques.
    Espinoza-Larios A; Ames CP; Chamberlain RH; Sonntag VK; Dickman CA; Crawford NR
    Spine J; 2007; 7(2):194-204. PubMed ID: 17321969
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Anterior transpedicular screw fixation of cervical spine: Is it safe? Morphological feasibility, technical properties, and accuracy of manual insertion.
    Koktekir E; Toktas ZO; Seker A; Akakin A; Konya D; Kilic T
    J Neurosurg Spine; 2015 Jun; 22(6):596-604. PubMed ID: 25815805
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Complications of transpedicular screw fixation in the cervical spine.
    Kast E; Mohr K; Richter HP; Börm W
    Eur Spine J; 2006 Mar; 15(3):327-34. PubMed ID: 15912352
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Biomechanical comparison of cervical transfacet pedicle screws versus pedicle screws.
    Liu GY; Xu RM; Ma WH; Sun SH; Huang L; Ying JW; Jiang WY
    Chin Med J (Engl); 2008 Aug; 121(15):1390-3. PubMed ID: 18959115
    [TBL] [Abstract][Full Text] [Related]  

  • 8. [Application of the pedicle screw in the subaxial cervical spine].
    Zhang YP; Xu QF; Lu LJ; Li J; Hong JJ
    Zhongguo Gu Shang; 2015 Feb; 28(2):126-9. PubMed ID: 25924493
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Cervical pedicle screws: conventional versus computer-assisted placement of cannulated screws.
    Richter M; Cakir B; Schmidt R
    Spine (Phila Pa 1976); 2005 Oct; 30(20):2280-7. PubMed ID: 16227890
    [TBL] [Abstract][Full Text] [Related]  

  • 10. [Comparative study between 3D guide plate assisted and free-hand insertion of anterior cervical transpedicular screw].
    Li J; Zhao LJ; Zheng MZ; Gan KF; Chen YL; Feng ZX; Pan LX; Xu JX; Fan TD; Chen JY; Zhao FD
    Zhongguo Gu Shang; 2021 Jan; 34(1):45-50. PubMed ID: 33666019
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Biomechanical assessment of anterior lumbar interbody fusion with an anterior lumbosacral fixation screw-plate: comparison to stand-alone anterior lumbar interbody fusion and anterior lumbar interbody fusion with pedicle screws in an unstable human cadaver model.
    Gerber M; Crawford NR; Chamberlain RH; Fifield MS; LeHuec JC; Dickman CA
    Spine (Phila Pa 1976); 2006 Apr; 31(7):762-8. PubMed ID: 16582849
    [TBL] [Abstract][Full Text] [Related]  

  • 12. [Experimental study of cervical pedicle screw locator system].
    Cao J; Xu R; Zhou L; Zhong Z; Ma W; Li M
    Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi; 2009 Apr; 23(4):393-5. PubMed ID: 19431971
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Lateral mass screw-rod fixation of the cervical spine: a prospective clinical series with 1-year follow-up.
    Deen HG; Birch BD; Wharen RE; Reimer R
    Spine J; 2003; 3(6):489-95. PubMed ID: 14609694
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Corpectomy versus discectomy for the treatment of multilevel cervical spine pathology: a finite element model analysis.
    Hussain M; Nassr A; Natarajan RN; An HS; Andersson GB
    Spine J; 2012 May; 12(5):401-8. PubMed ID: 22572585
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Anterior pedicle screw and plate fixation for cervical facet dislocation: case series and technical note.
    Zhang Z; Mu Z; Zheng W
    Spine J; 2016 Jan; 16(1):123-9. PubMed ID: 26409419
    [TBL] [Abstract][Full Text] [Related]  

  • 16. [Anatomic comparison between spinous process screws and pedicle screws techniques of the second cervical vertebar].
    Liu GY; Xu RM; Ma WH; Sun SH; Lin HJ; Feng JX; Hu Y; Zhao LJ; Zhou LJ
    Zhongguo Gu Shang; 2011 Aug; 24(8):659-61. PubMed ID: 21928672
    [TBL] [Abstract][Full Text] [Related]  

  • 17. The security analysis of transpedicular screw fixation in the lower cervical spine and a case report.
    Huang D; Du K; Zeng S; Gao W; Huang L; Su P
    Spine (Phila Pa 1976); 2011 Dec; 36(26):E1702-8. PubMed ID: 22138783
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Cervical pedicle screws vs. lateral mass screws: uniplanar fatigue analysis and residual pullout strengths.
    Johnston TL; Karaikovic EE; Lautenschlager EP; Marcu D
    Spine J; 2006; 6(6):667-72. PubMed ID: 17088197
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Anterior cervical discectomy and fusion with a locked plate and wedged graft effectively stabilizes flexion-distraction stage-3 injury in the lower cervical spine: a biomechanical study.
    Paxinos O; Ghanayem AJ; Zindrick MR; Voronov LI; Havey RM; Carandang G; Hadjipavlou A; Patwardhan AG
    Spine (Phila Pa 1976); 2009 Jan; 34(1):E9-15. PubMed ID: 19127153
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Cervical pedicle screw placement using the "key slot technique": the feasibility and learning curve.
    Lee SH; Kim KT; Abumi K; Suk KS; Lee JH; Park KJ
    J Spinal Disord Tech; 2012 Dec; 25(8):415-21. PubMed ID: 21959833
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.