BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

159 related articles for article (PubMed ID: 25175057)

  • 1. Wear and creep behavior of total knee implants undergoing wear testing.
    Teeter MG; Parikh A; Taylor M; Sprague J; Naudie DD
    J Arthroplasty; 2015 Jan; 30(1):130-4. PubMed ID: 25175057
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Third-body abrasive wear of tibial polyethylene inserts combined with metallic and ceramic femoral components in a knee simulator study.
    Zietz C; Bergschmidt P; Lange R; Mittelmeier W; Bader R
    Int J Artif Organs; 2013 Jan; 36(1):47-55. PubMed ID: 23335379
    [TBL] [Abstract][Full Text] [Related]  

  • 3. In vitro quantification of wear in tibial inserts using microcomputed tomography.
    Teeter MG; Naudie DD; McErlain DD; Brandt JM; Yuan X; Macdonald SJ; Holdsworth DW
    Clin Orthop Relat Res; 2011 Jan; 469(1):107-12. PubMed ID: 20676810
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Measurements of surface and subsurface damage in retrieved polyethylene tibial inserts of a contemporary design.
    Teeter MG; Brandt JM; Naudie DD; Bohm ER; McCalden RW; Holdsworth DW
    J Long Term Eff Med Implants; 2012; 22(1):21-31. PubMed ID: 23016787
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Comparison of articular and backside polyethylene wear in mobile bearing unicompartmental knee replacement.
    Teeter MG; Howard JL; McCalden RW; Naudie DD
    Knee; 2017 Mar; 24(2):429-433. PubMed ID: 28189405
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Metrology to quantify wear and creep of polyethylene tibial knee inserts.
    Muratoglu OK; Perinchief RS; Bragdon CR; O'Connor DO; Konrad R; Harris WH
    Clin Orthop Relat Res; 2003 May; (410):155-64. PubMed ID: 12771826
    [TBL] [Abstract][Full Text] [Related]  

  • 7. [Research progress of polyethylene inserts wear measurement and evaluation in total knee arthroplasty].
    Zhao F; Wang C; Fan Y
    Zhongguo Yi Liao Qi Xie Za Zhi; 2015 Jan; 39(1):33-6. PubMed ID: 26027291
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Tibial interface wear in retrieved total knee components and correlations with modular insert motion.
    Rao AR; Engh GA; Collier MB; Lounici S
    J Bone Joint Surg Am; 2002 Oct; 84(10):1849-55. PubMed ID: 12377918
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Assessment of backside wear from the analysis of 55 retrieved tibial inserts.
    Li S; Scuderi G; Furman BD; Bhattacharyya S; Schmieg JJ; Insall JN
    Clin Orthop Relat Res; 2002 Nov; (404):75-82. PubMed ID: 12439241
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Total Articular Knee Replacement Using Polyurethane.
    Pritchett JW
    J Knee Surg; 2020 Mar; 33(3):242-246. PubMed ID: 30716773
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Contribution of Surface Polishing and Sterilization Method to Backside Wear in Total Knee Arthroplasty.
    Teeter MG; Lanting BA; Shrestha KR; Howard JL; Vasarhelyi EM
    J Arthroplasty; 2015 Dec; 30(12):2320-2. PubMed ID: 26182981
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Can Sequentially-irradiated and Annealed Highly Cross-linked Polyethylene Inserts Thinner than Eight-millimeters Be Utilized in Total Knee Arthroplasty?
    Sayeed SA; Jauregui JJ; Korduba LA; Essner A; Harwin SF; Delanois RE; Mont MA
    Surg Technol Int; 2015 May; 26():329-35. PubMed ID: 26055028
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Surface Damage Is Not Reduced With Highly Crosslinked Polyethylene Tibial Inserts at Short-term.
    Liu T; Esposito C; Elpers M; Wright T
    Clin Orthop Relat Res; 2016 Jan; 474(1):107-16. PubMed ID: 26084848
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Can microcomputed tomography measure retrieved polyethylene wear? Comparing fixed-bearing and rotating-platform knees.
    Engh CA; Zimmerman RL; Hopper RH; Engh GA
    Clin Orthop Relat Res; 2013 Jan; 471(1):86-93. PubMed ID: 22879092
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Peripheral snap-fit locking mechanisms and smooth surface finish of tibial trays reduce backside wear in fixed-bearing total knee arthroplasty.
    Łapaj Ł; Mróz A; Kokoszka P; Markuszewski J; Wendland J; Helak-Łapaj C; Kruczyński J
    Acta Orthop; 2017 Feb; 88(1):62-69. PubMed ID: 27781667
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Oxidized zirconium femoral components reduce polyethylene wear in a knee wear simulator.
    Ezzet KA; Hermida JC; Colwell CW; D'Lima DD
    Clin Orthop Relat Res; 2004 Nov; (428):120-4. PubMed ID: 15534531
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Technique to quantify subsurface cracks in retrieved polyethylene components using micro-CT.
    Teeter MG; Yuan X; Naudie DD; Holdsworth DW
    J Long Term Eff Med Implants; 2010; 20(1):27-34. PubMed ID: 21284585
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Backside wear of polyethylene tibial inserts: mechanism and magnitude of material loss.
    Conditt MA; Thompson MT; Usrey MM; Ismaily SK; Noble PC
    J Bone Joint Surg Am; 2005 Feb; 87(2):326-31. PubMed ID: 15687155
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Effects of in vitro wear of machined and molded UHMWPE tibial inserts on TKR kinematics.
    Benson LC; DesJardins JD; LaBerge M
    J Biomed Mater Res; 2001; 58(5):496-504. PubMed ID: 11505423
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Ceramic versus cobalt-chrome femoral components; wear of polyethylene insert in total knee prosthesis.
    Oonishi H; Ueno M; Kim SC; Oonishi H; Iwamoto M; Kyomoto M
    J Arthroplasty; 2009 Apr; 24(3):374-82. PubMed ID: 18524533
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.