These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

151 related articles for article (PubMed ID: 25179459)

  • 1. Measurement of cardiac output in children by pressure-recording analytical method.
    Urbano J; López J; González R; Solana MJ; Fernández SN; Bellón JM; López-Herce J
    Pediatr Cardiol; 2015 Feb; 36(2):358-64. PubMed ID: 25179459
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Cardiac index assessment by the pressure recording analytic method in critically ill unstable patients after cardiac surgery.
    Barile L; Landoni G; Pieri M; Ruggeri L; Maj G; Nigro Neto C; Pasin L; Cabrini L; Zangrillo A
    J Cardiothorac Vasc Anesth; 2013 Dec; 27(6):1108-13. PubMed ID: 23992652
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Thermodilution vs pressure recording analytical method in hemodynamic stabilized patients.
    Donati A; Carsetti A; Tondi S; Scorcella C; Domizi R; Damiani E; Gabbanelli V; Münch C; Adrario E; Pelaia P; Cecconi M
    J Crit Care; 2014 Apr; 29(2):260-4. PubMed ID: 24332994
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Pressure recording analytical method for measuring cardiac output in critically ill children: a validation study.
    Saxena R; Durward A; Puppala NK; Murdoch IA; Tibby SM
    Br J Anaesth; 2013 Mar; 110(3):425-31. PubMed ID: 23183320
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Cardiac index assessment by the pressure recording analytic method in unstable patients with atrial fibrillation.
    Maj G; Monaco F; Landoni G; Barile L; Nicolotti D; Pieri M; Melisurgo G; Pappalardo F; Zangrillo A
    J Cardiothorac Vasc Anesth; 2011 Jun; 25(3):476-80. PubMed ID: 21147000
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Comparison between pressure-recording analytical method (PRAM) and femoral arterial thermodilution method (FATD) cardiac output monitoring in an infant animal model of cardiac arrest.
    Urbano J; López J; González R; Fernández SN; Solana MJ; Toledo B; Carrillo Á; López-Herce J
    Intensive Care Med Exp; 2016 Dec; 4(1):13. PubMed ID: 27256288
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Measuring cardiac output in children undergoing cardiac catheterization: comparison between the Fick method and PRAM (pressure recording analytical method).
    Alonso-Iñigo JM; Escribá FJ; Carrasco JI; Fas MJ; Argente P; Galvis JM; Llopis JE
    Paediatr Anaesth; 2016 Nov; 26(11):1097-1105. PubMed ID: 27565740
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Assessment of cardiac output from systemic arterial pressure in humans.
    Romano SM; Pistolesi M
    Crit Care Med; 2002 Aug; 30(8):1834-41. PubMed ID: 12163802
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Pulse Wave Analysis Using the Pressure Recording Analytical Method to Measure Cardiac Output in Pediatric Cardiac Surgery Patients: A Method Comparison Study Using Transesophageal Doppler Echocardiography as Reference Method.
    Greiwe G; Balfanz V; Hapfelmeier A; Zajonz TS; Müller M; Saugel B; Schulte-Uentrop L
    Anesth Analg; 2022 Jul; 135(1):71-78. PubMed ID: 35452017
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Cardiac output monitoring by pressure recording analytical method in cardiac surgery.
    Giomarelli P; Biagioli B; Scolletta S
    Eur J Cardiothorac Surg; 2004 Sep; 26(3):515-20. PubMed ID: 15302045
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Cardiac index assessment by the pressure recording analytical method in infants after paediatric cardiac surgery: a pilot retrospective study.
    Favia I; Rizza A; Garisto C; Haiberger R; Di Chiara L; Romagnoli S; Ricci Z
    Interact Cardiovasc Thorac Surg; 2016 Dec; 23(6):919-923. PubMed ID: 27481679
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Assessment of cardiac output in children: a comparison between the pressure recording analytical method and Doppler echocardiography.
    Calamandrei M; Mirabile L; Muschetta S; Gensini GF; De Simone L; Romano SM
    Pediatr Crit Care Med; 2008 May; 9(3):310-2. PubMed ID: 18446106
    [TBL] [Abstract][Full Text] [Related]  

  • 13. A preliminary study evaluating cardiac output measurement using Pressure Recording Analytical Method (PRAM) in anaesthetized dogs.
    Briganti A; Evangelista F; Centonze P; Rizzo A; Bentivegna F; Crovace A; Staffieri F
    BMC Vet Res; 2018 Mar; 14(1):72. PubMed ID: 29510691
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Continuous cardiac output monitoring with an uncalibrated pulse contour method in patients supported with mechanical pulsatile assist device.
    Scolletta S; Miraldi F; Romano SM; Muzzi L
    Interact Cardiovasc Thorac Surg; 2011 Jul; 13(1):52-6. PubMed ID: 21454314
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Cardiac output by arterial pulse contour: reliability under hemodynamic derangements.
    Romagnoli S; Romano SM; Bevilacqua S; Ciappi F; Lazzeri C; Peris A; Dini D; Gelsomino S
    Interact Cardiovasc Thorac Surg; 2009 Jun; 8(6):642-6. PubMed ID: 19299422
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Agreement between cardiac output measurements by pulse wave analysis using the Pressure Recording Analytical Method and transthoracic echocardiography in patients with veno-venous extracorporeal membrane oxygenation therapy: An observational method comparison.
    Greiwe G; Flick M; Hapfelmeier A; Winkler MS; Nitzschke R; Frings D; Saugel B
    Eur J Anaesthesiol; 2023 Jun; 40(6):436-441. PubMed ID: 37052059
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Lack of agreement between pulmonary arterial thermodilution cardiac output and the pressure recording analytical method in postoperative cardiac surgery patients.
    Paarmann H; Groesdonk HV; Sedemund-Adib B; Hanke T; Heinze H; Heringlake M; Schön J
    Br J Anaesth; 2011 Apr; 106(4):475-81. PubMed ID: 21205624
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Pressure recording analytical method and bioreactance for stroke volume index monitoring during pediatric cardiac surgery.
    Garisto C; Favia I; Ricci Z; Romagnoli S; Haiberger R; Polito A; Cogo P
    Paediatr Anaesth; 2015 Feb; 25(2):143-9. PubMed ID: 24491036
    [TBL] [Abstract][Full Text] [Related]  

  • 19. FloTrac/Vigileo(TM) (third generation) and MostCare(®)/PRAM versus echocardiography for cardiac output estimation in vascular surgery.
    Romagnoli S; Ricci Z; Romano SM; Dimizio F; Bonicolini E; Quattrone D; De Gaudio R
    J Cardiothorac Vasc Anesth; 2013 Dec; 27(6):1114-21. PubMed ID: 24055563
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Pressure recording analytical method (PRAM) for measurement of cardiac output during various haemodynamic states.
    Scolletta S; Romano SM; Biagioli B; Capannini G; Giomarelli P
    Br J Anaesth; 2005 Aug; 95(2):159-65. PubMed ID: 15894561
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.