  • 21. An ultra-compact low temperature scanning probe microscope for magnetic fields above 30 T.
    Rossi L; Gerritsen JW; Nelemans L; Khajetoorians AA; Bryant B
    Rev Sci Instrum; 2018 Nov; 89(11):113706. PubMed ID: 30501346
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Effect of horizontal magnetization reversal of the tips on magnetic force microscopy images.
    Alekseev A; Popkov A; Shubin A; Pudonin F; Djuzhev N
    Ultramicroscopy; 2014 Jan; 136():91-5. PubMed ID: 24051098
    [TBL] [Abstract][Full Text] [Related]  

  • 23. A High Rigidity and Precision Scanning Tunneling Microscope with Decoupled
    Chen X; Guo T; Hou Y; Zhang J; Meng W; Lu Q
    Scanning; 2017; 2017():1020476. PubMed ID: 29270242
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Differential magnetic force microscope imaging.
    Wang Y; Wang Z; Liu J; Hou L
    Scanning; 2015; 37(2):112-5. PubMed ID: 25652733
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Polarization-preserving confocal microscope for optical experiments in a dilution refrigerator with high magnetic field.
    Sladkov M; Bakker MP; Chaubal AU; Reuter D; Wieck AD; van der Wal CH
    Rev Sci Instrum; 2011 Apr; 82(4):043105. PubMed ID: 21528993
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Atomic imaging with a 12 T magnetic field perpendicular or parallel to the sample surface by an ultra-stable scanning tunneling microscope.
    Wang J; Li W; Meng W; Hou Y; Lu Y; Lu Q
    Ultramicroscopy; 2023 Sep; 251():113774. PubMed ID: 37270856
    [TBL] [Abstract][Full Text] [Related]  

  • 27. A simple, compact, and rigid piezoelectric step motor with large step size.
    Wang Q; Lu Q
    Rev Sci Instrum; 2009 Aug; 80(8):085104. PubMed ID: 19725678
    [TBL] [Abstract][Full Text] [Related]  

  • 28. An interchangeable scanning Hall probe/scanning SQUID microscope.
    Tang CC; Lin HT; Wu SL; Chen TJ; Wang MJ; Ling DC; Chi CC; Chen JC
    Rev Sci Instrum; 2014 Aug; 85(8):083707. PubMed ID: 25173276
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Design of a variable temperature scanning force microscope.
    Nazaretski E; Graham KS; Thompson JD; Wright JA; Pelekhov DV; Hammel PC; Movshovich R
    Rev Sci Instrum; 2009 Aug; 80(8):083704. PubMed ID: 19725659
    [TBL] [Abstract][Full Text] [Related]  

  • 30. A scanning Hall probe microscope for high resolution magnetic imaging down to 300 mK.
    Khotkevych VV; Milosević MV; Bending SJ
    Rev Sci Instrum; 2008 Dec; 79(12):123708. PubMed ID: 19123570
    [TBL] [Abstract][Full Text] [Related]  

  • 31. A hybrid magnet based scanning tunneling microscope.
    Wang J; Geng T; Meng W; Huang P; Zhao K; Zhang J; Feng Q; Guo T; Xiang K; Hou Y; Chen W; Lu Y; Lu Q
    Rev Sci Instrum; 2020 May; 91(5):053702. PubMed ID: 32486730
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Compact, single-tube scanning tunneling microscope with thermoelectric cooling.
    Jobbins MM; Agostino CJ; Michel JD; Gans AR; Kandel SA
    Rev Sci Instrum; 2013 Oct; 84(10):103708. PubMed ID: 24182120
    [TBL] [Abstract][Full Text] [Related]  

  • 33. New design for inertial piezoelectric motors.
    Liu L; Ge W; Meng W; Hou Y; Zhang J; Lu Q
    Rev Sci Instrum; 2018 Mar; 89(3):033704. PubMed ID: 29604738
    [TBL] [Abstract][Full Text] [Related]  

  • 34. A 350 mK, 9 T scanning tunneling microscope for the study of superconducting thin films on insulating substrates and single crystals.
    Kamlapure A; Saraswat G; Ganguli SC; Bagwe V; Raychaudhuri P; Pai SP
    Rev Sci Instrum; 2013 Dec; 84(12):123905. PubMed ID: 24387444
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Compact low temperature scanning tunneling microscope with in-situ sample preparation capability.
    Kim J; Nam H; Qin S; Kim SU; Schroeder A; Eom D; Shih CK
    Rev Sci Instrum; 2015 Sep; 86(9):093707. PubMed ID: 26429448
    [TBL] [Abstract][Full Text] [Related]  

  • 36. A high-stability scanning tunneling microscope achieved by an isolated tiny scanner with low voltage imaging capability.
    Wang Q; Hou Y; Wang J; Lu Q
    Rev Sci Instrum; 2013 Nov; 84(11):113703. PubMed ID: 24289400
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Magnetic domain structure imaging near sample surface with alternating magnetic force microscopy by using AC magnetic field modulated superparamagnetic tip.
    Cao Y; Nakayama S; Kumar P; Zhao Y; Kinoshita Y; Yoshimura S; Saito H
    Nanotechnology; 2018 Jul; 29(30):305502. PubMed ID: 29722293
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Ultrahigh vacuum, variable temperature, dual scanning tunneling microscope system operating under high magnetic field.
    Cai W; Pang F; Wang J; Liu H; Liang XJ; Xue QK; Chen DM
    Rev Sci Instrum; 2007 Jun; 78(6):065108. PubMed ID: 17614639
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Design and properties of a cryogenic dip-stick scanning tunneling microscope with capacitive coarse approach control.
    Schlegel R; Hänke T; Baumann D; Kaiser M; Nag PK; Voigtländer R; Lindackers D; Büchner B; Hess C
    Rev Sci Instrum; 2014 Jan; 85(1):013706. PubMed ID: 24517774
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Isolated scan unit and scanning tunneling microscope for stable imaging in ultra-high magnetic fields.
    Wang J; Li Z; Zhao K; Dong S; Wu D; Meng W; Zhang J; Hou Y; Lu Y; Lu Q
    Ultramicroscopy; 2024 Jul; 261():113960. PubMed ID: 38547811
    [TBL] [Abstract][Full Text] [Related]  