151 related articles for article (PubMed ID: 25194517)
1. Surgical training using three-dimensional simulation in placement of cervical lateral mass screws: a blinded randomized control trial.
Gottschalk MB; Yoon ST; Park DK; Rhee JM; Mitchell PM
Spine J; 2015 Jan; 15(1):168-75. PubMed ID: 25194517
[TBL] [Abstract][Full Text] [Related]
2. Anatomy of Lamina in the Subaxial Cervical Spine With the Special Reference to Translaminar Screws: CT and Cadaveric Analysis With Screw Trajectory Simulation.
Cho W; Le JT; Shimer AL; Werner BC; Glaser JA; Shen FH
Clin Spine Surg; 2017 Jun; 30(5):E535-E539. PubMed ID: 28525474
[TBL] [Abstract][Full Text] [Related]
3. The medial cortical pedicle screw--a new technique for cervical pedicle screw placement with partial drilling of medial cortex.
Mahesh B; Upendra B; Mahan RS
Spine J; 2014 Feb; 14(2):371-80. PubMed ID: 24444420
[TBL] [Abstract][Full Text] [Related]
4. Use of spinous processes to determine drill trajectory during placement of lateral mass screws: a cadaveric analysis.
Chin KR; Eiszner JR; Roh JS; Bohlman HH
J Spinal Disord Tech; 2006 Feb; 19(1):18-21. PubMed ID: 16462213
[TBL] [Abstract][Full Text] [Related]
5. A pilot study of the utility of a laboratory-based spinal fixation training program for neurosurgical residents.
Sundar SJ; Healy AT; Kshettry VR; Mroz TE; Schlenk R; Benzel EC
J Neurosurg Spine; 2016 May; 24(5):850-6. PubMed ID: 26771374
[TBL] [Abstract][Full Text] [Related]
6. Development of a new technique for pedicle screw and Magerl screw insertion using a 3-dimensional image guide.
Kawaguchi Y; Nakano M; Yasuda T; Seki S; Hori T; Kimura T
Spine (Phila Pa 1976); 2012 Nov; 37(23):1983-8. PubMed ID: 22531473
[TBL] [Abstract][Full Text] [Related]
7. Computed tomography assessment of lateral pedicle wall perforation by free-hand subaxial cervical pedicle screw placement.
Wang Y; Xie J; Yang Z; Zhao Z; Zhang Y; Li T; Liu L
Arch Orthop Trauma Surg; 2013 Jul; 133(7):901-9. PubMed ID: 23632781
[TBL] [Abstract][Full Text] [Related]
8. A novel patient-specific navigational template for cervical pedicle screw placement.
Lu S; Xu YQ; Lu WW; Ni GX; Li YB; Shi JH; Li DP; Chen GP; Chen YB; Zhang YZ
Spine (Phila Pa 1976); 2009 Dec; 34(26):E959-66. PubMed ID: 20010385
[TBL] [Abstract][Full Text] [Related]
9. Percutaneous placement of posterior cervical screws using three-dimensional fluoroscopy.
Holly LT; Foley KT
Spine (Phila Pa 1976); 2006 Mar; 31(5):536-40; discussion 541. PubMed ID: 16508547
[TBL] [Abstract][Full Text] [Related]
10. A novel computer-assisted drill guide template for lumbar pedicle screw placement: a cadaveric and clinical study.
Lu S; Xu YQ; Zhang YZ; Li YB; Xie L; Shi JH; Guo H; Chen GP; Chen YB
Int J Med Robot; 2009 Jun; 5(2):184-91. PubMed ID: 19280584
[TBL] [Abstract][Full Text] [Related]
11. The accuracy of the lateral vertebral notch-referred pedicle screw insertion technique in subaxial cervical spine: a human cadaver study.
Luo J; Wu C; Huang Z; Pan Z; Li Z; Zhong J; Chen Y; Han Z; Cao K
Arch Orthop Trauma Surg; 2017 Apr; 137(4):517-522. PubMed ID: 28236185
[TBL] [Abstract][Full Text] [Related]
12. Clinical accuracy of three-dimensional fluoroscopy-based computer-assisted cervical pedicle screw placement: a retrospective comparative study of conventional versus computer-assisted cervical pedicle screw placement.
Ishikawa Y; Kanemura T; Yoshida G; Ito Z; Muramoto A; Ohno S
J Neurosurg Spine; 2010 Nov; 13(5):606-11. PubMed ID: 21039152
[TBL] [Abstract][Full Text] [Related]
13. Accuracy of fluoroscopy versus computer-assisted navigation for the placement of anterior cervical pedicle screws.
Patton AG; Morris RP; Kuo YF; Lindsey RW
Spine (Phila Pa 1976); 2015 Apr; 40(7):E404-10. PubMed ID: 25599290
[TBL] [Abstract][Full Text] [Related]
14. Paravertebral foramen screw fixation for posterior cervical spine fusion: biomechanical study and description of a novel technique.
Maki S; Aramomi M; Matsuura Y; Furuya T; Ota M; Iijima Y; Saito J; Suzuki T; Mannoji C; Takahashi K; Yamazaki M; Koda M
J Neurosurg Spine; 2017 Oct; 27(4):415-420. PubMed ID: 28498072
[TBL] [Abstract][Full Text] [Related]
15. Rapid prototype patient-specific drill template for cervical pedicle screw placement.
Owen BD; Christensen GE; Reinhardt JM; Ryken TC
Comput Aided Surg; 2007 Sep; 12(5):303-8. PubMed ID: 17957538
[TBL] [Abstract][Full Text] [Related]
16. Accuracy Assessment of Pedicle and Lateral Mass Screw Insertion Assisted by Customized 3D-Printed Drill Guides: A Human Cadaver Study.
Pijpker PAJ; Kraeima J; Witjes MJH; Oterdoom DLM; Coppes MH; Groen RJM; Kuijlen JMA
Oper Neurosurg (Hagerstown); 2019 Jan; 16(1):94-102. PubMed ID: 29660055
[TBL] [Abstract][Full Text] [Related]
17. The accuracy of 3D fluoroscopy-navigated screw insertion in the upper and subaxial cervical spine.
Bredow J; Oppermann J; Kraus B; Schiller P; Schiffer G; Sobottke R; Eysel P; Koy T
Eur Spine J; 2015 Dec; 24(12):2967-76. PubMed ID: 25925249
[TBL] [Abstract][Full Text] [Related]
18. Computed tomography-based determination of a safe trajectory for placement of transarticular facet screws in the subaxial cervical spine.
Jost GF; Bisson EF; Schmidt MH
J Neurosurg Spine; 2012 Apr; 16(4):334-9. PubMed ID: 22284230
[TBL] [Abstract][Full Text] [Related]
19. Role of Visuohaptic Surgical Training Simulator in Resident Education of Orthopedic Surgery.
Shi J; Hou Y; Lin Y; Chen H; Yuan W
World Neurosurg; 2018 Mar; 111():e98-e104. PubMed ID: 29253700
[TBL] [Abstract][Full Text] [Related]
20. Comparison of navigated versus non-navigated pedicle screw placement in 260 patients and 1434 screws: screw accuracy, screw size, and the complexity of surgery.
Luther N; Iorgulescu JB; Geannette C; Gebhard H; Saleh T; Tsiouris AJ; Härtl R
J Spinal Disord Tech; 2015 Jun; 28(5):E298-303. PubMed ID: 23511642
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]