These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
262 related articles for article (PubMed ID: 25195664)
1. Mechatronic system for in-bore MRI-guided insertion of needles to the prostate: An in vivo needle guidance accuracy study. Cepek J; Lindner U; Ghai S; Louis AS; Davidson SR; Gertner M; Hlasny E; Sussman MS; Fenster A; Trachtenberg J J Magn Reson Imaging; 2015 Jul; 42(1):48-55. PubMed ID: 25195664 [TBL] [Abstract][Full Text] [Related]
2. A system for MRI-guided transperineal delivery of needles to the prostate for focal therapy. Cepek J; Chronik BA; Lindner U; Trachtenberg J; Davidson SR; Bax J; Fenster A Med Phys; 2013 Jan; 40(1):012304. PubMed ID: 23298109 [TBL] [Abstract][Full Text] [Related]
3. Toward mechatronic MRI-guided focal laser ablation of the prostate: Robust registration for improved needle delivery. Knull E; Park CKS; Bax J; Tessier D; Fenster A Med Phys; 2023 Mar; 50(3):1259-1273. PubMed ID: 36583505 [TBL] [Abstract][Full Text] [Related]
4. Design and validation of an MRI-compatible mechatronic system for needle delivery to localized prostate cancer. Knull E; Bax JS; Park CKS; Tessier D; Fenster A Med Phys; 2021 Sep; 48(9):5283-5299. PubMed ID: 34131933 [TBL] [Abstract][Full Text] [Related]
5. 3T MR-guided in-bore transperineal prostate biopsy: A comparison of robotic and manual needle-guidance templates. Tilak G; Tuncali K; Song SE; Tokuda J; Olubiyi O; Fennessy F; Fedorov A; Penzkofer T; Tempany C; Hata N J Magn Reson Imaging; 2015 Jul; 42(1):63-71. PubMed ID: 25263213 [TBL] [Abstract][Full Text] [Related]
6. High-field MRI-compatible needle placement robot for prostate interventions. Su H; Camilo A; Cole GA; Hata N; Tempany CM; Fischer GS Stud Health Technol Inform; 2011; 163():623-9. PubMed ID: 21335868 [TBL] [Abstract][Full Text] [Related]
7. Towards human-controlled, real-time shape sensing based flexible needle steering for MRI-guided percutaneous therapies. Li M; Li G; Gonenc B; Duan X; Iordachita I Int J Med Robot; 2017 Jun; 13(2):. PubMed ID: 27487833 [TBL] [Abstract][Full Text] [Related]
8. In vivo evaluation of angulated needle-guide template for MRI-guided transperineal prostate biopsy. Moreira P; Grimble J; Iftimia N; Bay CP; Tuncali K; Park J; Tokuda J Med Phys; 2021 May; 48(5):2553-2565. PubMed ID: 33651407 [TBL] [Abstract][Full Text] [Related]
9. A Hand-Held Assistant for Semiautomated Percutaneous Needle Steering. Rossa C; Usmani N; Sloboda R; Tavakoli M IEEE Trans Biomed Eng; 2017 Mar; 64(3):637-648. PubMed ID: 28113208 [TBL] [Abstract][Full Text] [Related]
11. Interventional MRI-guided local delivery of agents into swine bile duct walls using MR-compatible needle-integrated balloon catheter system. Zhang F; Bai Z; Shi Y; Wang J; Li Y; Yang X NMR Biomed; 2015 Jun; 28(6):679-84. PubMed ID: 25900480 [TBL] [Abstract][Full Text] [Related]
12. Development of an MRI-compatible device for prostate focal therapy. Cepek J; Chronik B; Lindner U; Trachtenberg J; Fenster A Med Image Comput Comput Assist Interv; 2012; 15(Pt 1):455-62. PubMed ID: 23285583 [TBL] [Abstract][Full Text] [Related]
13. Transperineal prostate biopsy under magnetic resonance image guidance: a needle placement accuracy study. Blumenfeld P; Hata N; DiMaio S; Zou K; Haker S; Fichtinger G; Tempany CM J Magn Reson Imaging; 2007 Sep; 26(3):688-94. PubMed ID: 17729363 [TBL] [Abstract][Full Text] [Related]
15. Magnetic resonance imaging-guided biopsy in the musculoskeletal system using a cylindrical 1.5-T magnetic resonance imaging unit. Ahrar JU; Stafford RJ; Alzubaidi S; Ahrar K Top Magn Reson Imaging; 2011 Aug; 22(4):189-96. PubMed ID: 23514926 [TBL] [Abstract][Full Text] [Related]
16. Robotic system for transrectal biopsy of the prostate: real-time guidance under MRI. Elhawary H; Tse ZT; Rea M; Zivanovic A; Davies BL; Besant C; de Souza NM; McRobbie D; Young I; Lampérth MU IEEE Eng Med Biol Mag; 2010; 29(2):78-86. PubMed ID: 20659844 [TBL] [Abstract][Full Text] [Related]
17. Precision targeting of liver lesions using a novel electromagnetic navigation device in physiologic phantom and swine. Banovac F; Tang J; Xu S; Lindisch D; Chung HY; Levy EB; Chang T; McCullough MF; Yaniv Z; Wood BJ; Cleary K Med Phys; 2005 Aug; 32(8):2698-705. PubMed ID: 16193801 [TBL] [Abstract][Full Text] [Related]
18. Feasibility of 3.0T magnetic resonance imaging-guided laser ablation of a cadaveric prostate. Woodrum DA; Gorny KR; Mynderse LA; Amrami KK; Felmlee JP; Bjarnason H; Garcia-Medina OI; McNichols RJ; Atwell TD; Callstrom MR Urology; 2010 Jun; 75(6):1514.e1-6. PubMed ID: 20381834 [TBL] [Abstract][Full Text] [Related]
19. Passive marker tracking via phase-only cross correlation (POCC) for MR-guided needle interventions: initial in vivo experience. Krafft AJ; Zamecnik P; Maier F; de Oliveira A; Hallscheidt P; Schlemmer HP; Bock M Phys Med; 2013 Nov; 29(6):607-14. PubMed ID: 23084541 [TBL] [Abstract][Full Text] [Related]
20. Technical feasibility of transperineal MR-guided prostate interventions in a low-field open MRI unit: canine study. Lakosi F; Antal G; Vandulek C; Kovacs A; Garamvolgyi R; Petnehazy O; Bajzik G; Hadjiev J; Repa I; Bogner P Pathol Oncol Res; 2009 Sep; 15(3):315-22. PubMed ID: 18946728 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]