BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

333 related articles for article (PubMed ID: 25203376)

  • 21. Changes in Clinical Practice Reduce the Rate of Anastomotic Leakage After Colorectal Resections.
    Iversen H; Ahlberg M; Lindqvist M; Buchli C
    World J Surg; 2018 Jul; 42(7):2234-2241. PubMed ID: 29282510
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Influence of multiple stapler firings used for rectal division on colorectal anastomotic leak rate.
    Braunschmid T; Hartig N; Baumann L; Dauser B; Herbst F
    Surg Endosc; 2017 Dec; 31(12):5318-5326. PubMed ID: 28634627
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Techniques for colorectal anastomosis.
    Ho YH; Ashour MA
    World J Gastroenterol; 2010 Apr; 16(13):1610-21. PubMed ID: 20355239
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Stapled versus handsewn methods for colorectal anastomosis surgery.
    Lustosa SA; Matos D; Atallah AN; Castro AA
    Cochrane Database Syst Rev; 2001; (3):CD003144. PubMed ID: 11687041
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Is There Necessity for Oversewing the Staple Line During Laparoscopic Sleeve Gastrectomy? An Updated Systematic Review and Meta-Analysis of Randomized Controlled Trials.
    Wu C; Wang FG; Yan WM; Yan M; Song MM
    J Invest Surg; 2020 Oct; 33(9):839-850. PubMed ID: 31805796
    [No Abstract]   [Full Text] [Related]  

  • 26. The impact of stapling technique and surgeon specialism on anastomotic failure after right-sided colorectal resection: an international multicentre, prospective audit.
    2015 European Society of Coloproctology Collaborating Group
    Colorectal Dis; 2018 Nov; 20(11):1028-1040. PubMed ID: 29920945
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Intra-operative double-stapled colorectal or coloanal anastomotic complications of laparoscopic low anterior resection for rectal cancer: double-stapled anastomotic complication could result in persistent anastomotic leakage.
    Kim JH; Kim HY; Lee IK; Oh ST; Kim JG; Lee YS
    Surg Endosc; 2015 Nov; 29(11):3117-24. PubMed ID: 25519426
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Factors associated with the occurrence of leaks in stapled rectal anastomoses: a review of 1,014 patients.
    Vignali A; Fazio VW; Lavery IC; Milsom JW; Church JM; Hull TL; Strong SA; Oakley JR
    J Am Coll Surg; 1997 Aug; 185(2):105-13. PubMed ID: 9249076
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Comprehensive literature review of the outcome, modifications, and alternatives to double-stapled low pelvic colorectal anastomosis.
    Emile SH; Barsom SH; Elfallal AH; Wexner SD
    Surgery; 2022 Aug; 172(2):512-521. PubMed ID: 35393126
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Does advancement in stapling technology with triple-row and enhanced staple configurations confer additional safety? A matched comparison of 340 stapled ileocolic anastomoses.
    Foo CC; Chiu AHO; Yip J; Law WL
    Surg Endosc; 2018 Jul; 32(7):3122-3130. PubMed ID: 29340808
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Individual surgeon is an independent risk factor for leak after double-stapled colorectal anastomosis: An institutional analysis of 800 patients.
    García-Granero E; Navarro F; Cerdán Santacruz C; Frasson M; García-Granero A; Marinello F; Flor-Lorente B; Espí A
    Surgery; 2017 Nov; 162(5):1006-1016. PubMed ID: 28739093
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Intraoperative endoscopy for the assessment of circular-stapled anastomosis in laparoscopic colon surgery.
    Shamiyeh A; Szabo K; Ulf Wayand W; Zehetner J
    Surg Laparosc Endosc Percutan Tech; 2012 Feb; 22(1):65-7. PubMed ID: 22318063
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Stapled versus handsewn methods for colorectal anastomosis surgery.
    Neutzling CB; Lustosa SA; Proenca IM; da Silva EM; Matos D
    Cochrane Database Syst Rev; 2012 Feb; (2):CD003144. PubMed ID: 22336786
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Colorectal anastomosis during cytoreductive radical surgery in patients with peritoneal surface malignancies. Validation of a new technique (without stoma) to prevent anastomosis leakage in more than 1000 procedures.
    Barrios P; Ramos I; Crusellas O; Sabia D; Mompart S; Martín-Baranera M
    Clin Transl Oncol; 2021 Jun; 23(6):1201-1209. PubMed ID: 33393053
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Reduction in anastomotic strictures using bioabsorbable circular staple line reinforcement in laparoscopic gastric bypass.
    Scott JD; Cobb WS; Carbonell AM; Traxler B; Bour ES
    Surg Obes Relat Dis; 2011; 7(5):637-42. PubMed ID: 21388891
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Anastomotic Leakage Using Linear Stapling Device with Pre-attached Bioabsorbable Polyglycolic Acid Felt After Laparoscopic Anterior Resection.
    Yamamoto S; Kanai T; Osumi K; Yo K; Takano K; Tsutsui M; Nakanishi R; Yoshikawa Y; Kaneko Y; Nakagawa M
    Anticancer Res; 2017 Dec; 37(12):7083-7086. PubMed ID: 29187499
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Is Circular Fibrin Sealing of Low Rectal Anastomosis Able to Prevent Leakage in 21-Day Follow-up? Randomized Experimental Trial in Pigs.
    Wenger FA; Szucsik E; Hoinoiu BF; Cimpean AM; Matonick JP; Ionac M; Raica M
    Surg Innov; 2019 Aug; 26(4):408-419. PubMed ID: 31056009
    [No Abstract]   [Full Text] [Related]  

  • 38. Three-row versus two-row circular staplers for left-sided colorectal anastomosis: a propensity score-matched analysis of the iCral 2 and 3 prospective cohorts.
    Catarci M; Guadagni S; Masedu F; Ruffo G; Viola MG; Borghi F; Baldazzi G; Scatizzi M;
    Int J Surg; 2023 Aug; 109(8):2312-2323. PubMed ID: 37195782
    [TBL] [Abstract][Full Text] [Related]  

  • 39. The Relationship Between the Number of Intersections of Staple Lines and Anastomotic Leakage After the Use of a Double Stapling Technique in Laparoscopic Colorectal Surgery.
    Lee S; Ahn B; Lee S
    Surg Laparosc Endosc Percutan Tech; 2017 Aug; 27(4):273-281. PubMed ID: 28614172
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Reducing anastomotic leakage by reinforcement of colorectal anastomosis with cyanoacrylate glue.
    Wu Z; Vakalopoulos KA; Kroese LF; Boersema GS; Kleinrensink GJ; Jeekel J; Lange JF
    Eur Surg Res; 2013; 50(3-4):255-61. PubMed ID: 23736305
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 17.