These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

110 related articles for article (PubMed ID: 2520631)

  • 1. Arterial puncture during venous cannulation.
    Ellison N; Jobes DR
    J Cardiothorac Anesth; 1989 Feb; 3(1):135-6. PubMed ID: 2520631
    [No Abstract]   [Full Text] [Related]  

  • 2. Head rotation during internal jugular vein cannulation and the risk of carotid artery puncture.
    Daniel M
    Anesth Analg; 1996 Sep; 83(3):660. PubMed ID: 8780308
    [No Abstract]   [Full Text] [Related]  

  • 3. Cerebral infarct following central venous cannulation.
    Zaidi NA; Khan M; Naqvi HI; Kamal RS
    Anaesthesia; 1998 Feb; 53(2):186-91. PubMed ID: 9534646
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Accidental carotid artery catheterization during attempted central venous catheter placement: a case report.
    Maietta PM
    AANA J; 2012 Aug; 80(4):251-5. PubMed ID: 23251993
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Internal jugular vein cannulation confused with carotid artery cannulation.
    Williamson K; Latto IP
    Anaesthesia; 1999 Apr; 54(4):399-400. PubMed ID: 10455854
    [No Abstract]   [Full Text] [Related]  

  • 6. Avoiding unintentional arterial cannulation.
    Silverman SM; Olson KW
    Crit Care Med; 1990 Apr; 18(4):460. PubMed ID: 2318060
    [No Abstract]   [Full Text] [Related]  

  • 7. External or internal jugular cannulation?
    Duncan M
    Anaesthesia; 1998 Oct; 53(10):1032. PubMed ID: 9893556
    [No Abstract]   [Full Text] [Related]  

  • 8. Accidental arterial puncture during right internal jugular vein cannulation in cardiac surgical patients.
    Maddali MM; Arun V; Wala AA; Al-Bahrani MJ; Jayatilaka CM; Nishant AR
    Ann Card Anaesth; 2016; 19(4):594-598. PubMed ID: 27716688
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Inadvertent carotid artery cannulation during pulmonary artery catheter insertion.
    Eckhardt WF; Iaconetti J; Kwon JS; Brown E; Troianos CA
    J Cardiothorac Vasc Anesth; 1996 Feb; 10(2):283-90. PubMed ID: 8850412
    [No Abstract]   [Full Text] [Related]  

  • 10. Safe internal jugular vein cannulation.
    Augoustides JG; Jobes DR; Diaz D; Weiner J
    J Cardiothorac Vasc Anesth; 2002 Apr; 16(2):262-3. PubMed ID: 11957184
    [No Abstract]   [Full Text] [Related]  

  • 11. Carotid arterial cannulation: removing the risk with ultrasound?
    Thompson C; Barrows T
    Can J Anaesth; 2009 Jun; 56(6):471-2. PubMed ID: 19396508
    [No Abstract]   [Full Text] [Related]  

  • 12. [Accidental arterial catheterization during insertion of a central line for internal jugular access].
    Ganière V; Christen G; Tagan D
    Rev Med Suisse; 2006 Mar; 2(55):612-3. PubMed ID: 16562606
    [No Abstract]   [Full Text] [Related]  

  • 13. Ultrasound-guided central venous cannulation: false sense of security.
    Mittnacht AJ
    Anesth Analg; 2009 Dec; 109(6):2029; author reply 2031. PubMed ID: 19923540
    [No Abstract]   [Full Text] [Related]  

  • 14. Increased venous hemoglobin saturation during percutaneous right internal jugular vein cannulation in a patient with a mature right forearm arteriovenous hemodialysis fistula.
    Yee LL; Despotis GJ
    Anesthesiology; 1990 Jul; 73(1):184-6. PubMed ID: 2360730
    [No Abstract]   [Full Text] [Related]  

  • 15. Locating the right internal jugular vein using ultrasound is different than ultrasound guidance or ultrasound confirmation of right internal jugular vein cannulation.
    Miller BR
    Anesth Analg; 2010 Mar; 110(3):974-5. PubMed ID: 20185676
    [No Abstract]   [Full Text] [Related]  

  • 16. [Iatrogenic common carotid artery injury secondary to an internal jugular venous catheterization].
    Lame CA; Loum B; Keita I; Diallo TB; Sow A
    Pan Afr Med J; 2017; 26():18. PubMed ID: 28450997
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Cervical and Mediastinal Hematoma Caused by a Carotid Injury After Jugular Vein Cannulation, Treated by Stent.
    Llàcer-Millán E; Ramírez P; Sanmartín J; Zamarro J; Parrilla P
    Cir Esp; 2015 May; 93(5):342-4. PubMed ID: 24655796
    [No Abstract]   [Full Text] [Related]  

  • 18. Claude Bernard-Horner syndrome caused by jugular vein cannulation for chronic hemodialysis.
    Trezzi M; Londrino F; Chiappini N; Cavallini M; Martina V; Rombolà G
    J Vasc Access; 2013; 14(3):305. PubMed ID: 23599140
    [No Abstract]   [Full Text] [Related]  

  • 19. [Failed puncture of the jugular vein. The patient's neck swelled up].
    Maurer MH; Marnitz T
    MMW Fortschr Med; 2011 Dec; 153(49-50):5. PubMed ID: 22308582
    [No Abstract]   [Full Text] [Related]  

  • 20. Carotid artery-internal jugular vein fistula: A complication of internal jugular vein catheterization.
    Ezri T; Szmuk P; Cohen Y; Simon D; Mavor E; Katz J; Geva D
    J Cardiothorac Vasc Anesth; 2001 Apr; 15(2):231-2. PubMed ID: 11312486
    [No Abstract]   [Full Text] [Related]  

    [Next]    [New Search]
    of 6.