These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

160 related articles for article (PubMed ID: 2520934)

  • 21. The effect of a bellows leak in an Ohmeda 7810 ventilator on room contamination, inspired oxygen, airway pressure, and tidal volume.
    Lampotang S; Sanchez JC; Chen B; Gravenstein N
    Anesth Analg; 2005 Jul; 101(1):151-4, table of contents. PubMed ID: 15976223
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Effects of assisted ventilation on the work of breathing: volume-controlled versus pressure-controlled ventilation.
    Cinnella G; Conti G; Lofaso F; Lorino H; Harf A; Lemaire F; Brochard L
    Am J Respir Crit Care Med; 1996 Mar; 153(3):1025-33. PubMed ID: 8630541
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Comparison of volume control and pressure control ventilation: is flow waveform the difference?
    Davis K; Branson RD; Campbell RS; Porembka DT
    J Trauma; 1996 Nov; 41(5):808-14. PubMed ID: 8913208
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Effects of peak inspiratory flow on development of ventilator-induced lung injury in rabbits.
    Maeda Y; Fujino Y; Uchiyama A; Matsuura N; Mashimo T; Nishimura M
    Anesthesiology; 2004 Sep; 101(3):722-8. PubMed ID: 15329597
    [TBL] [Abstract][Full Text] [Related]  

  • 25. [Proportional assist ventilation: methodology therapeutics on COPD patients compared with pressure support ventilation].
    Ye Q; Wang C; Tong Z
    Zhonghua Jie He He Hu Xi Za Zhi; 2000 Apr; 23(4):228-31. PubMed ID: 11778211
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Higher Fresh Gas Flow Rates Decrease Tidal Volume During Pressure Control Ventilation.
    Mohammad S; Gravenstein N; Gonsalves D; Vasilopoulos T; Lampotang S
    Anesth Analg; 2017 May; 124(5):1506-1511. PubMed ID: 28333703
    [TBL] [Abstract][Full Text] [Related]  

  • 27. [The effects of fresh gas flow rate on the work of breathing during semi-closed circuit anesthesia].
    Yamada T; Kakoi H; Hirokawa T; Koyama K; Miyao H; Kawasaki J; Kawazoe T
    Masui; 1994 Jan; 43(1):55-8. PubMed ID: 8309055
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Using conventional infant ventilators at unconventional rates.
    Boros SJ; Bing DR; Mammel MC; Hagen E; Gordon MJ
    Pediatrics; 1984 Oct; 74(4):487-92. PubMed ID: 6384912
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Breathing pattern and gas exchange at peak exercise in COPD patients with and without tidal flow limitation at rest.
    Díaz O; Villafranca C; Ghezzo H; Borzone G; Leiva A; Milic-Emili J; Lisboa C
    Eur Respir J; 2001 Jun; 17(6):1120-7. PubMed ID: 11491153
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Efficacy of expiratory tracheal gas insufflation in a canine model of lung injury.
    Nahum A; Shapiro RS; Ravenscraft SA; Adams AB; Marini JJ
    Am J Respir Crit Care Med; 1995 Aug; 152(2):489-95. PubMed ID: 7633697
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Lung aeration during ventilation after recruitment guided by tidal elimination of carbon dioxide and dynamic compliance was better than after end-tidal carbon dioxide targeted ventilation: a computed tomography study in surfactant-depleted piglets.
    Hanson A; Göthberg S; Nilsson K; Hedenstierna G
    Pediatr Crit Care Med; 2011 Nov; 12(6):e362-8. PubMed ID: 21263364
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Obstructive flow-volume loop contours after single lung transplantation.
    Ross DJ; Belman MJ; Mohsenifar Z; Nathan SD; Kass RM; Koerner SK
    J Heart Lung Transplant; 1994; 13(3):508-13. PubMed ID: 8061028
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Significant reduction in minute ventilation and peak inspiratory pressures with arteriovenous CO2 removal during severe respiratory failure.
    Tao W; Brunston RL; Bidani A; Pirtle P; Dy J; Cardenas VJ; Traber DL; Zwischenberger JB
    Crit Care Med; 1997 Apr; 25(4):689-95. PubMed ID: 9142037
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Aspiration of airway dead space. A new method to enhance CO2 elimination.
    De Robertis E; Sigurdsson SE; Drefeldt B; Jonson B
    Am J Respir Crit Care Med; 1999 Mar; 159(3):728-32. PubMed ID: 10051243
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Expiratory washout versus optimization of mechanical ventilation during permissive hypercapnia in patients with severe acute respiratory distress syndrome.
    Richecoeur J; Lu Q; Vieira SR; Puybasset L; Kalfon P; Coriat P; Rouby JJ
    Am J Respir Crit Care Med; 1999 Jul; 160(1):77-85. PubMed ID: 10390383
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Alterations in peak inspiratory pressure and tidal volume delivered by manually operated self-inflating resuscitation bags as a function of the oxygen supply rate.
    Godoy AC; Vieira RJ; De Capitani EM
    J Bras Pneumol; 2008 Oct; 34(10):817-21. PubMed ID: 19009215
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Effectiveness of pressure support ventilation for mechanical ventilatory support in patients with status asthmaticus.
    Tokioka H; Saito S; Takahashi T; Kinjo M; Saeki S; Kosaka F; Hirakawa M
    Acta Anaesthesiol Scand; 1992 Jan; 36(1):5-9. PubMed ID: 1539479
    [TBL] [Abstract][Full Text] [Related]  

  • 38. The effect of increased apparatus dead space and tidal volumes on carbon dioxide elimination and oxygen saturations in a low-flow anesthesia system.
    Enekvist BJ; Luttropp HH; Johansson A
    J Clin Anesth; 2008 May; 20(3):170-4. PubMed ID: 18502358
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Volume-controlled ventilation and pressure-controlled inverse ratio ventilation: a comparison of their effects in ARDS patients.
    Mancebo J; Vallverdú I; Bak E; Domínguez G; Subirana M; Benito S; Net A
    Monaldi Arch Chest Dis; 1994 Jun; 49(3):201-7. PubMed ID: 8087114
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Effects of changes of frequency and tidal volume of controlled ventilation: measurements at constant arterial Pco2 in dogs.
    Lunn JN; Mapleson WW; Chilcoat RT
    Br J Anaesth; 1975 Jan; 47(1):2-16. PubMed ID: 1148071
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]