These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

210 related articles for article (PubMed ID: 25220781)

  • 1. A study of force distribution of loading stresses on implant-bone interface on short implant length using 3-dimensional finite element analysis.
    Kang N; Wu YY; Gong P; Yue L; Ou GM
    Oral Surg Oral Med Oral Pathol Oral Radiol; 2014 Nov; 118(5):519-23. PubMed ID: 25220781
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Effects of implant diameter, insertion depth, and loading angle on stress/strain fields in implant/jawbone systems: finite element analysis.
    Qian L; Todo M; Matsushita Y; Koyano K
    Int J Oral Maxillofac Implants; 2009; 24(5):877-86. PubMed ID: 19865628
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Implant-bone interface stress distribution in immediately loaded implants of different diameters: a three-dimensional finite element analysis.
    Ding X; Zhu XH; Liao SH; Zhang XH; Chen H
    J Prosthodont; 2009 Jul; 18(5):393-402. PubMed ID: 19374710
    [TBL] [Abstract][Full Text] [Related]  

  • 4. The influence of implant diameter and length on stress distribution of osseointegrated implants related to crestal bone geometry: a three-dimensional finite element analysis.
    Baggi L; Cappelloni I; Di Girolamo M; Maceri F; Vairo G
    J Prosthet Dent; 2008 Dec; 100(6):422-31. PubMed ID: 19033026
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Biomechanical effects of a maxillary implant in the augmented sinus: a three-dimensional finite element analysis.
    Huang HL; Fuh LJ; Ko CC; Hsu JT; Chen CC
    Int J Oral Maxillofac Implants; 2009; 24(3):455-62. PubMed ID: 19587867
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Effect of diameter and length on stress distribution of the alveolar crest around immediate loading implants.
    Ding X; Liao SH; Zhu XH; Zhang XH; Zhang L
    Clin Implant Dent Relat Res; 2009 Dec; 11(4):279-87. PubMed ID: 18783411
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Evaluation of multiple implant-bone parameters on stress characteristics in the mandible under traumatic loading conditions.
    Guan H; van Staden R; Loo YC; Johnson N; Ivanovski S; Meredith N
    Int J Oral Maxillofac Implants; 2010; 25(3):461-72. PubMed ID: 20556244
    [TBL] [Abstract][Full Text] [Related]  

  • 8. The use of finite element analysis to model bone-implant contact with basal implants.
    Ihde S; Goldmann T; Himmlova L; Aleksic Z
    Oral Surg Oral Med Oral Pathol Oral Radiol Endod; 2008 Jul; 106(1):39-48. PubMed ID: 18439855
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Platform switching: biomechanical evaluation using three-dimensional finite element analysis.
    Tabata LF; Rocha EP; Barão VA; Assunção WG
    Int J Oral Maxillofac Implants; 2011; 26(3):482-91. PubMed ID: 21691594
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Influence of percentage of osseointegration on stress distribution around dental implants.
    Lai H; Zhang F; Zhang B; Yang C; Xue M
    Chin J Dent Res; 1998 Dec; 1(3):7-11. PubMed ID: 10557165
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Stress and strain patterns of 1-piece and 2-piece implant systems in bone: a 3-dimensional finite element analysis.
    Ormianer Z; Ben Amar A; Duda M; Marku-Cohen S; Lewinstein I
    Implant Dent; 2012 Feb; 21(1):39-45. PubMed ID: 22223190
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Evaluation of the cylinder implant thread height and width: a 3-dimensional finite element analysis.
    Kong L; Hu K; Li D; Song Y; Yang J; Wu Z; Liu B
    Int J Oral Maxillofac Implants; 2008; 23(1):65-74. PubMed ID: 18416414
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Finite element analysis of effect of prosthesis height, angle of force application, and implant offset on supporting bone.
    Sütpideler M; Eckert SE; Zobitz M; An KN
    Int J Oral Maxillofac Implants; 2004; 19(6):819-25. PubMed ID: 15623056
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Three-dimensional finite element analysis of titanium and yttrium-stabilized zirconium dioxide abutments and implants.
    Çaglar A; Bal BT; Karakoca S; Aydın C; Yılmaz H; Sarısoy S
    Int J Oral Maxillofac Implants; 2011; 26(5):961-9. PubMed ID: 22010077
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Evaluation of stresses occurring on three different zirconia dental implants: three-dimensional finite element analysis.
    Caglar A; Bal BT; Aydin C; Yilmaz H; Ozkan S
    Int J Oral Maxillofac Implants; 2010; 25(1):95-103. PubMed ID: 20209191
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Biomechanical evaluation of platform switching in different implant protocols: computed tomography-based three-dimensional finite element analysis.
    Pessoa RS; Vaz LG; Marcantonio E; Vander Sloten J; Duyck J; Jaecques SV
    Int J Oral Maxillofac Implants; 2010; 25(5):911-9. PubMed ID: 20862404
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Influence of tapered and external hexagon connections on bone stresses around tilted dental implants: three-dimensional finite element method with statistical analysis.
    de Faria Almeida DA; Pellizzer EP; Verri FR; Santiago JF; de Carvalho PS
    J Periodontol; 2014 Feb; 85(2):261-9. PubMed ID: 23688104
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Stress analysis in platform-switching implants: a 3-dimensional finite element study.
    Pellizzer EP; Verri FR; Falcón-Antenucci RM; Júnior JF; de Carvalho PS; de Moraes SL; Noritomi PY
    J Oral Implantol; 2012 Oct; 38(5):587-94. PubMed ID: 20932121
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Biomechanical effect of platform switching in implant dentistry: a three-dimensional finite element analysis.
    Chang CL; Chen CS; Hsu ML
    Int J Oral Maxillofac Implants; 2010; 25(2):295-304. PubMed ID: 20369087
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Biomechanical effects of two different collar implant structures on stress distribution under cantilever fixed partial dentures.
    Merıç G; Erkmen E; Kurt A; Eser A; özden AU
    Acta Odontol Scand; 2011 Nov; 69(6):374-84. PubMed ID: 21449688
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 11.