177 related articles for article (PubMed ID: 25222856)
1. Latex-enhanced turbidimetric immunoassay for everolimus in whole blood using the Nanopia TDM everolimus assay with the JCA-BM6010 automatic analyzer.
Mori K; Kimura S; Matsui M; Suehisa E; Hidaka Y; Fukushima N
Ther Drug Monit; 2014 Oct; 36(5):677-80. PubMed ID: 25222856
[TBL] [Abstract][Full Text] [Related]
2. Analytical performance of QMS everolimus assay on ortho Vitros 5,1 FS fusion analyzer: measuring everolimus trough levels for solid organ transplant recipients.
Shu I; Wright AM; Chandler WL; Bernard DW; Wang P
Ther Drug Monit; 2014 Apr; 36(2):264-8. PubMed ID: 24232125
[TBL] [Abstract][Full Text] [Related]
3. Evaluation of QMS everolimus assay using Hitachi 917 Analyzer: comparison with liquid chromatography/mass spectrometry.
Dasgupta A; Davis B; Chow L
Ther Drug Monit; 2011 Apr; 33(2):149-54. PubMed ID: 21266941
[TBL] [Abstract][Full Text] [Related]
4. Evaluation of QMS everolimus assay using Indiko analyzer: comparison with an ultra-performance liquid chromatography-tandem mass spectrometry method.
Buthiau D; Bargnoux AS; Badiou S; Sutra T; Dupuy AM; Pageaux GP; Mourad G; Cristol JP
Ther Drug Monit; 2015 Apr; 37(2):275-8. PubMed ID: 25254414
[TBL] [Abstract][Full Text] [Related]
5. Everolimus TDM using Thermo Fisher QMS immunoassay on Indiko, Beckman DxC, AU680, and AU5800 analyzers.
Wong SH; Johnson-Davis KL; Garrison K; Rankin JD; Muhammad CS
Clin Biochem; 2017 May; 50(7-8):425-430. PubMed ID: 27988326
[TBL] [Abstract][Full Text] [Related]
6. Analytical performance of a new liquid chromatography/tandem mass spectrometric method for determination of everolimus concentrations in whole blood.
McMillin GA; Johnson-Davis K; Dasgupta A
Ther Drug Monit; 2012 Apr; 34(2):222-6. PubMed ID: 22322402
[TBL] [Abstract][Full Text] [Related]
7. A direct method for the measurement of everolimus and sirolimus in whole blood by LC-MS/MS using an isotopic everolimus internal standard.
Morgan PE; Brown NW; Tredger JM
Ther Drug Monit; 2014 Jun; 36(3):358-65. PubMed ID: 24305629
[TBL] [Abstract][Full Text] [Related]
8. Comparison of fluorescent polarization immunoassay (FPIA) versus HPLC to measure everolimus blood concentrations in clinical transplantation.
Khoschsorur G; Fruehwirth F; Zelzer S; Stettin M; Halwachs-Baumann G
Clin Chim Acta; 2007 May; 380(1-2):217-21. PubMed ID: 17320846
[TBL] [Abstract][Full Text] [Related]
9. Liquid chromatography-tandem mass spectrometry outperforms fluorescence polarization immunoassay in monitoring everolimus therapy in renal transplantation.
Moes DJ; Press RR; de Fijter JW; Guchelaar HJ; den Hartigh J
Ther Drug Monit; 2010 Aug; 32(4):413-9. PubMed ID: 20535052
[TBL] [Abstract][Full Text] [Related]
10. Evaluation of a novel commercial assay for the determination of cyclosporine A, tacrolimus, sirolimus, and everolimus by liquid chromatography-tandem mass spectrometric assay.
Becker S; Thiery J; Ceglarek U
Ther Drug Monit; 2013 Feb; 35(1):129-32. PubMed ID: 23188181
[TBL] [Abstract][Full Text] [Related]
11. Comparison of electrochemiluminescence immunoassay and latex agglutination turbidimetric immunoassay for evaluation of everolimus blood concentrations in renal transplant patients.
Akamine Y; Sato S; Kagaya H; Ohkubo T; Satoh S; Miura M
J Clin Pharm Ther; 2018 Oct; 43(5):675-681. PubMed ID: 29679392
[TBL] [Abstract][Full Text] [Related]
12. An automated nanoparticle-based homogeneous immunoassay for determining docetaxel concentrations in plasma.
Cline DJ; Zhang H; Lundell GD; Harney RL; Riaz HK; Jarrah J; Li Y; Miyazaki M; Courtney JB; Baburina I; Salamone SJ
Ther Drug Monit; 2013 Dec; 35(6):803-8. PubMed ID: 24263639
[TBL] [Abstract][Full Text] [Related]
13. [Determination of elastase 1 in plasma or serum by latex turbidometric immunoassay with automatic analyzer].
Ohde K; Sawai T
Rinsho Byori; 2002 Apr; 50(4):376-80. PubMed ID: 12014017
[TBL] [Abstract][Full Text] [Related]
14. Fast LC-MS/MS analysis of tacrolimus, sirolimus, everolimus and cyclosporin A in dried blood spots and the influence of the hematocrit and immunosuppressant concentration on recovery.
Koster RA; Alffenaar JW; Greijdanus B; Uges DR
Talanta; 2013 Oct; 115():47-54. PubMed ID: 24054560
[TBL] [Abstract][Full Text] [Related]
15. Analytical performance evaluation of a new turbidimetric immunoassay for valproic acid on the ADVIA 1650 analyzer: effect of gross hemolysis and high bilirubin.
Datta P; Dasgupta A
J Clin Lab Anal; 2005; 19(2):31-5. PubMed ID: 15756706
[TBL] [Abstract][Full Text] [Related]
16. Determination of everolimus in blood samples from kidney and liver transplant recipients using the sirolimus chemiluminescence magnetic microparticle immunoassay (CMIA) on the Architect-i1000® system.
Hermida-Cadahia EF; Tutor JC
Scand J Clin Lab Invest; 2012 Apr; 72(2):180-3. PubMed ID: 22248047
[TBL] [Abstract][Full Text] [Related]
17. Evaluation of the Abbott ARCHITECT i2000 sirolimus assay and comparison with the Abbott IMx sirolimus assay and an established liquid chromatography-tandem mass spectrometry method.
Johnson-Davis KL; De S; Jimenez E; McMillin GA; De BK
Ther Drug Monit; 2011 Aug; 33(4):453-9. PubMed ID: 21743377
[TBL] [Abstract][Full Text] [Related]
18. High-performance liquid chromatography versus immunoassay for the measurement of sirolimus: comparison of two methods.
Zochowska D; Bartłomiejczyk I; Kamińska A; Senatorski G; Paczek L
Transplant Proc; 2006; 38(1):78-80. PubMed ID: 16504669
[TBL] [Abstract][Full Text] [Related]
19. Two rapid ultra performance liquid chromatography/tandem mass spectrometry (UPLC/MS/MS) methods with common sample pretreatment for therapeutic drug monitoring of immunosuppressants compared to immunoassay.
Tszyrsznic W; Borowiec A; Pawlowska E; Jazwiec R; Zochowska D; Bartlomiejczyk I; Zegarska J; Paczek L; Dadlez M
J Chromatogr B Analyt Technol Biomed Life Sci; 2013 Jun; 928():9-15. PubMed ID: 23584041
[TBL] [Abstract][Full Text] [Related]
20. High-performance liquid chromatography with ultraviolet detection for therapeutic drug monitoring of everolimus.
Baldelli S; Murgia S; Merlini S; Zenoni S; Perico N; Remuzzi G; Cattaneo D
J Chromatogr B Analyt Technol Biomed Life Sci; 2005 Feb; 816(1-2):99-105. PubMed ID: 15664339
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]