BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

91 related articles for article (PubMed ID: 25223705)

  • 1. PA/Lateral chest X-ray is equivalent to cine-fluoroscopy for the detection of conductor externalization in defibrillation leads.
    Steinberg C; Sarrazin JF; Philippon F; Champagne J; Molin F; Nault I; Blier L; Bouchard MA; Arsenault J; O'Hara G
    Pacing Clin Electrophysiol; 2015 Jan; 38(1):77-83. PubMed ID: 25223705
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Detection of high incidence of Riata lead breaches by systematic postero-anterior and lateral chest X-ray in a large cohort.
    Steinberg C; Sarrazin JF; Philippon F; Bouchard MA; O'Hara G; Molin F; Nault I; Blier L; Champagne J
    Europace; 2013 Mar; 15(3):402-8. PubMed ID: 23118004
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Longitudinal follow-up of Riata leads reveals high annual incidence of new conductor externalization and electrical failure.
    Steinberg C; Sarrazin JF; Philippon F; Champagne J; Bouchard MA; Molin F; Nault I; Blier L; O'Hara G
    J Interv Card Electrophysiol; 2014 Dec; 41(3):217-22. PubMed ID: 25399242
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Fluoroscopic investigation of Riata® transvenous defibrillator leads.
    Singh G; Lahiri MK; Khan A; Fang KD; Schuger CD
    Cardiol J; 2015; 22(1):57-67. PubMed ID: 24846515
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Prospective evaluation of cinefluoroscopy and chest radiography for Riata lead defects: implications for future lead screening.
    Lorvidhaya P; Mendoza I; Sehli S; Atalay MK; Kim MH
    J Interv Card Electrophysiol; 2013 Nov; 38(2):131-5. PubMed ID: 24013704
    [TBL] [Abstract][Full Text] [Related]  

  • 6. High prevalence of insulation failure with externalized cables in St. Jude Medical Riata family ICD leads: fluoroscopic grading scale and correlation to extracted leads.
    Parvathaneni SV; Ellis CR; Rottman JN
    Heart Rhythm; 2012 Aug; 9(8):1218-24. PubMed ID: 22449742
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Fluoroscopic and electrical assessment of implantable cardioverter defibrillator leads: a prospective observational study.
    McKeag NA; Hodkinson EC; Noad RL; Kodoth VN; Ashfield K; Wilson CM; McEneaney DJ; Roberts MJ
    Pacing Clin Electrophysiol; 2014 Nov; 37(11):1538-43. PubMed ID: 25081476
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Riata implantable cardioverter-defibrillator lead failure: analysis of explanted leads with a unique insulation defect.
    Hauser RG; McGriff D; Retel LK
    Heart Rhythm; 2012 May; 9(5):742-9. PubMed ID: 22209723
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Insulation defects in Riata implantable cardioverter-defibrillator leads.
    Sato A; Chinushi M; Iijima K; Izumi D; Furushima H
    Intern Med; 2012; 51(19):2689-94. PubMed ID: 23037457
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Prevalence and presentation of externalized conductors and electrical abnormalities in Riata defibrillator leads after fluoroscopic screening: report from the Netherlands Heart Rhythm Association Device Advisory Committee.
    Theuns DA; Elvan A; de Voogt W; de Cock CC; van Erven L; Meine M
    Circ Arrhythm Electrophysiol; 2012 Dec; 5(6):1059-63. PubMed ID: 23091049
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Fluoroscopic and electrical assessment of a series of defibrillation leads: prevalence of externalized conductors.
    Kodoth VN; Hodkinson EC; Noad RL; Ashfield KP; Cromie NA; McEneaney DJ; Wilson CM; Roberts MJ
    Pacing Clin Electrophysiol; 2012 Dec; 35(12):1498-504. PubMed ID: 23035735
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Mechanical and electrical dysfunction of Riata implantable cardioverter-defibrillator leads.
    Demirel F; Adiyaman A; Delnoy PP; Smit JJ; Ramdat Misier AR; Elvan A
    Europace; 2014 Dec; 16(12):1787-94. PubMed ID: 24843049
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Extreme externalisation of a Riata defibrillator lead conductor cable with prolapse into the left pulmonary artery.
    Oktay AA; Dibs SR; Silver JM; Akbar MS
    Heart Lung Circ; 2014 Dec; 23(12):e276-8. PubMed ID: 25190529
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Nationwide fluoroscopic screening of recalled Riata defibrillator leads in Denmark.
    Larsen JM; Riahi S; Nielsen JC; Videbaek R; Haarbo J; Due KM; Theuns DA; Johansen JB
    Heart Rhythm; 2013 Jun; 10(6):821-7. PubMed ID: 23416377
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Prevalence and predictors of cable extrusion and loss of electrical integrity with the Riata defibrillator lead.
    Shen S; Bhave P; Giedrimas E; Patel T; Arora R; Chicos AB; Goldberger JJ; Ilkhanoff L; Kim MH; Lin AC; Passman R; Lee R; Knight BP; Kim SS
    J Cardiovasc Electrophysiol; 2012 Nov; 23(11):1207-12. PubMed ID: 22697600
    [TBL] [Abstract][Full Text] [Related]  

  • 16. What did we learn from Riata™?
    Fischer A; Jenney C
    Herzschrittmacherther Elektrophysiol; 2015 Jun; 26(2):105-10. PubMed ID: 26054484
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Systematic fluoroscopic and electrical assessment of implantable cardioverter-defibrillator patients implanted with silicone-polyurethane copolymer (Optim™) coated leads.
    Forleo GB; Di Biase L; Panattoni G; Politano A; Magliano G; Santini L; Natale A; Romeo F
    Europace; 2014 Feb; 16(2):265-70. PubMed ID: 24042736
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Differential lead component pulling as a possible mechanism of inside-out abrasion and conductor cable externalization.
    Lau EW
    Pacing Clin Electrophysiol; 2013 Sep; 36(9):1072-89. PubMed ID: 23746039
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Progressive decrease in amplitude of intracardiac ventricular electrogram and higher left ventricular ejection fraction are associated with conductors' externalization in Riata leads.
    Kubala M; Traullé S; Leborgne L; Hermida JS
    Europace; 2013 Aug; 15(8):1198-204. PubMed ID: 23388185
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Increasing lead burden correlates with externalized cables during systematic fluoroscopic screening of Riata leads.
    Moorman LP; Moorman JR; DiMarco JP; Malhotra R; Darby A; Bilchick K; Ferguson JD; Mangrum JM; Kamath S; Mason PK
    J Interv Card Electrophysiol; 2013 Jun; 37(1):63-8. PubMed ID: 23254319
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 5.