308 related articles for article (PubMed ID: 25225962)
1. Safety and efficacy of a novel balloon colonoscope: a prospective cohort study.
Gralnek IM; Suissa A; Domanov S
Endoscopy; 2014 Oct; 46(10):883-7. PubMed ID: 25225962
[TBL] [Abstract][Full Text] [Related]
2. A prospective cohort study evaluating a novel colonoscopy platform featuring full-spectrum endoscopy.
Gralnek IM; Segol O; Suissa A; Siersema PD; Carr-Locke DL; Halpern Z; Santo E; Domanov S
Endoscopy; 2013 Sep; 45(9):697-702. PubMed ID: 23939509
[TBL] [Abstract][Full Text] [Related]
3. Impact of experience with a retrograde-viewing device on adenoma detection rates and withdrawal times during colonoscopy: the Third Eye Retroscope study group.
DeMarco DC; Odstrcil E; Lara LF; Bass D; Herdman C; Kinney T; Gupta K; Wolf L; Dewar T; Deas TM; Mehta MK; Anwer MB; Pellish R; Hamilton JK; Polter D; Reddy KG; Hanan I
Gastrointest Endosc; 2010 Mar; 71(3):542-50. PubMed ID: 20189513
[TBL] [Abstract][Full Text] [Related]
4. Advanced technology for the improvement of adenoma and polyp detection during colonoscopy.
Moriyama T; Uraoka T; Esaki M; Matsumoto T
Dig Endosc; 2015 Apr; 27 Suppl 1():40-4. PubMed ID: 25556542
[TBL] [Abstract][Full Text] [Related]
5. A randomized controlled trial assessing the effect of prescribed patient position changes during colonoscope withdrawal on adenoma detection.
Ou G; Kim E; Lakzadeh P; Tong J; Enns R; Ramji A; Whittaker S; Ko HH; Bressler B; Halparin L; Lam E; Amar J; Telford J
Gastrointest Endosc; 2014 Aug; 80(2):277-83. PubMed ID: 24629419
[TBL] [Abstract][Full Text] [Related]
6. G-EYE colonoscopy is superior to standard colonoscopy for increasing adenoma detection rate: an international randomized controlled trial (with videos).
Shirin H; Shpak B; Epshtein J; Karstensen JG; Hoffman A; de Ridder R; Testoni PA; Ishaq S; Reddy DN; Gross SA; Neumann H; Goetz M; Abramowich D; Moshkowitz M; Mizrahi M; Vilmann P; Rey JW; Sanduleanu-Dascalescu S; Viale E; Chaudhari H; Pochapin MB; Yair M; Shnell M; Yaari S; Hendel JW; Teubner D; Bogie RMM; Notaristefano C; Simantov R; Gluck N; Israeli E; Stigaard T; Matalon S; Vilkin A; Benson A; Sloth S; Maliar A; Waizbard A; Jacob H; Thielsen P; Shachar E; Rochberger S; Hershcovici T; Plougmann JI; Braverman M; Tsvang E; Abedi AA; Brachman Y; Siersema PD; Kiesslich R
Gastrointest Endosc; 2019 Mar; 89(3):545-553. PubMed ID: 30273591
[TBL] [Abstract][Full Text] [Related]
7. Feasibility of a novel colonoscope with extra-wide angle of view: a clinical study.
Uraoka T; Tanaka S; Oka S; Matsuda T; Saito Y; Moriyama T; Higashi R; Matsumoto T
Endoscopy; 2015 May; 47(5):444-8. PubMed ID: 25412088
[TBL] [Abstract][Full Text] [Related]
8. Safety, Feasibility, and Efficacy of Pancolonic Retroflexed Viewing Using a Short-turn Radius Colonoscope.
Robles-Medranda C; Soria-Alcívar M; Oleas R; Vargas M; Ospina J; Abarca F; Puga-Tejada M; Baquerizo-Burgos J; Pitanga-Lukashok H
J Clin Gastroenterol; 2019; 53(10):731-736. PubMed ID: 31135633
[TBL] [Abstract][Full Text] [Related]
9. Feasibility, safety, and diagnostic yield of the Extra Wide Angle View (EWAVE) colonoscope for the detection of colorectal lesions.
Bronzwaer MES; Dekker E; Weingart V; Groth S; Pioche M; Rivory J; Beyna T; Neuhaus H; Ponchon T; Allescher H; Fockens P; Rösch T
Endoscopy; 2018 Jan; 50(1):63-68. PubMed ID: 29132174
[TBL] [Abstract][Full Text] [Related]
10. Novel endocuff-assisted colonoscopy significantly increases the polyp detection rate: a randomized controlled trial.
Biecker E; Floer M; Heinecke A; Ströbel P; Böhme R; Schepke M; Meister T
J Clin Gastroenterol; 2015; 49(5):413-8. PubMed ID: 24921209
[TBL] [Abstract][Full Text] [Related]
11. A retrograde-viewing device improves detection of adenomas in the colon: a prospective efficacy evaluation (with videos).
Waye JD; Heigh RI; Fleischer DE; Leighton JA; Gurudu S; Aldrich LB; Li J; Ramrakhiani S; Edmundowicz SA; Early DS; Jonnalagadda S; Bresalier RS; Kessler WR; Rex DK
Gastrointest Endosc; 2010 Mar; 71(3):551-6. PubMed ID: 20018280
[TBL] [Abstract][Full Text] [Related]
12. A pilot study to assess the safety and efficacy of the Third Eye retrograde auxiliary imaging system during colonoscopy.
Triadafilopoulos G; Li J
Endoscopy; 2008 Jun; 40(6):478-82. PubMed ID: 18543136
[TBL] [Abstract][Full Text] [Related]
13. Effect of a retrograde-viewing device on adenoma detection rate during colonoscopy: the TERRACE study.
Leufkens AM; DeMarco DC; Rastogi A; Akerman PA; Azzouzi K; Rothstein RI; Vleggaar FP; Repici A; Rando G; Okolo PI; Dewit O; Ignjatovic A; Odstrcil E; East J; Deprez PH; Saunders BP; Kalloo AN; Creel B; Singh V; Lennon AM; Siersema PD;
Gastrointest Endosc; 2011 Mar; 73(3):480-9. PubMed ID: 21067735
[TBL] [Abstract][Full Text] [Related]
14. Cap, hood, cuff, and balloon - what next for colonoscopy?
Mohammed N; Rembacken B
Endoscopy; 2015 Jun; 47(6):564. PubMed ID: 26030894
[No Abstract] [Full Text] [Related]
15. Multicenter, randomized, tandem evaluation of EndoRings colonoscopy--results of the CLEVER study.
Dik VK; Gralnek IM; Segol O; Suissa A; Belderbos TD; Moons LM; Segev M; Domanov S; Rex DK; Siersema PD
Endoscopy; 2015 Dec; 47(12):1151-8. PubMed ID: 26220283
[TBL] [Abstract][Full Text] [Related]
16. Feasibility of full-spectrum endoscopy: Korea's first full-spectrum endoscopy colonoscopic trial.
Song JY; Cho YH; Kim MA; Kim JA; Lee CT; Lee MS
World J Gastroenterol; 2016 Feb; 22(8):2621-9. PubMed ID: 26937150
[TBL] [Abstract][Full Text] [Related]
17. Meta-analysis of the performance of ultrathin vs. standard colonoscopes.
Sofi AA; Nawras A; Khan MA; Howden CW; Lee WM
Endoscopy; 2017 Apr; 49(4):351-358. PubMed ID: 27852099
[No Abstract] [Full Text] [Related]
18. Cimetropium bromide does not improve polyp and adenoma detection during colonoscope withdrawal: A randomized, double-blind, placebo-controlled study.
Jung P; Park SB; Kim HW; Kang DH; W Choi C; Kim SJ; Nam HS; Ryu DG; Hong JB; Kim DJ
Medicine (Baltimore); 2018 Jun; 97(25):e11253. PubMed ID: 29924056
[TBL] [Abstract][Full Text] [Related]
19. Comparison of adenoma detection and miss rates between a novel balloon colonoscope and standard colonoscopy: a randomized tandem study.
Halpern Z; Gross SA; Gralnek IM; Shpak B; Pochapin M; Hoffman A; Mizrahi M; Rochberger YS; Moshkowitz M; Santo E; Melhem A; Grinshpon R; Pfefer J; Kiesslich R
Endoscopy; 2015 Mar; 47(3):238-44. PubMed ID: 25704662
[TBL] [Abstract][Full Text] [Related]
20. Nonneoplastic polypectomy during screening colonoscopy: the impact on polyp detection rate, adenoma detection rate, and overall cost.
Atia MA; Patel NC; Ratuapli SK; Boroff ES; Crowell MD; Gurudu SR; Faigel DO; Leighton JA; Ramirez FC
Gastrointest Endosc; 2015 Aug; 82(2):370-375.e1. PubMed ID: 25843614
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]