119 related articles for article (PubMed ID: 25226942)
1. Study of parameters for evaluating flow reduction with stents in a sidewall aneurysm phantom model.
Yu CH; Kwon TK
Biomed Mater Eng; 2014; 24(6):2417-24. PubMed ID: 25226942
[TBL] [Abstract][Full Text] [Related]
2. The impact of stent strut porosity on reducing flow in cerebral aneurysms.
Rayepalli S; Gupta R; Lum C; Majid A; Koochesfahani M
J Neuroimaging; 2013 Oct; 23(4):495-501. PubMed ID: 23980751
[TBL] [Abstract][Full Text] [Related]
3. Particle imaging velocimetry evaluation of intracranial stents in sidewall aneurysm: hemodynamic transition related to the stent design.
Bouillot P; Brina O; Ouared R; Lovblad KO; Farhat M; Pereira VM
PLoS One; 2014; 9(12):e113762. PubMed ID: 25470724
[TBL] [Abstract][Full Text] [Related]
4. In vitro evaluation of flow divertors in an elastase-induced saccular aneurysm model in rabbit.
Seong J; Wakhloo AK; Lieber BB
J Biomech Eng; 2007 Dec; 129(6):863-72. PubMed ID: 18067390
[TBL] [Abstract][Full Text] [Related]
5. Intracranial stents being modeled as a porous medium: flow simulation in stented cerebral aneurysms.
Augsburger L; Reymond P; Rufenacht DA; Stergiopulos N
Ann Biomed Eng; 2011 Feb; 39(2):850-63. PubMed ID: 21042856
[TBL] [Abstract][Full Text] [Related]
6. Implantation of pipeline flow-diverting stents reduces aneurysm inflow without relevantly affecting static intra-aneurysmal pressure.
Kerl HU; Boll H; Fiebig T; Figueiredo G; Förster A; Nölte IS; Nonn A; Groden C; Brockmann MA
Neurosurgery; 2014 Mar; 74(3):321-34; discussion 334. PubMed ID: 24549048
[TBL] [Abstract][Full Text] [Related]
7. Hemodynamics of Flow Diverters.
Dholakia R; Sadasivan C; Fiorella DJ; Woo HH; Lieber BB
J Biomech Eng; 2017 Feb; 139(2):. PubMed ID: 27727400
[TBL] [Abstract][Full Text] [Related]
8. Comparison among different high porosity stent configurations: hemodynamic effects of treatment in a large cerebral aneurysm.
Roszelle BN; Nair P; Gonzalez LF; Haithem Babiker M; Ryan J; Frakes D
J Biomech Eng; 2014 Feb; 136(2):021013. PubMed ID: 24337100
[TBL] [Abstract][Full Text] [Related]
9. Flow changes caused by the sequential placement of stents across the neck of sidewall cerebral aneurysms.
Cantón G; Levy DI; Lasheras JC; Nelson PK
J Neurosurg; 2005 Nov; 103(5):891-902. PubMed ID: 16304994
[TBL] [Abstract][Full Text] [Related]
10. Effect of flow diverter porosity on intraaneurysmal blood flow.
Augsburger L; Farhat M; Reymond P; Fonck E; Kulcsar Z; Stergiopulos N; Rüfenacht DA
Klin Neuroradiol; 2009 Aug; 19(3):204-14. PubMed ID: 19705075
[TBL] [Abstract][Full Text] [Related]
11. Intra-aneurysmal flow with helix and mesh stent placement across side-wall aneurysm pore of a straight parent vessel.
Liou TM; Liou SN; Chu KL
J Biomech Eng; 2004 Feb; 126(1):36-43. PubMed ID: 15171127
[TBL] [Abstract][Full Text] [Related]
12. Particle image velocimetry assessment of stent design influence on intra-aneurysmal flow.
Lieber BB; Livescu V; Hopkins LN; Wakhloo AK
Ann Biomed Eng; 2002 Jun; 30(6):768-77. PubMed ID: 12220077
[TBL] [Abstract][Full Text] [Related]
13. Effects of stent porosity on hemodynamics in a sidewall aneurysm model.
Liou TM; Li YC
J Biomech; 2008; 41(6):1174-83. PubMed ID: 18377914
[TBL] [Abstract][Full Text] [Related]
14. Hemodynamic transition driven by stent porosity in sidewall aneurysms.
Bouillot P; Brina O; Ouared R; Lovblad KO; Farhat M; Pereira VM
J Biomech; 2015 May; 48(7):1300-9. PubMed ID: 25798761
[TBL] [Abstract][Full Text] [Related]
15. Our capricious vessels: The influence of stent design and vessel geometry on the mechanics of intracranial aneurysm stent deployment.
De Bock S; Iannaccone F; De Santis G; De Beule M; Mortier P; Verhegghe B; Segers P
J Biomech; 2012 May; 45(8):1353-9. PubMed ID: 22483228
[TBL] [Abstract][Full Text] [Related]
16. The effect of stent porosity and strut shape on saccular aneurysm and its numerical analysis with lattice Boltzmann method.
Kim YH; Xu X; Lee JS
Ann Biomed Eng; 2010 Jul; 38(7):2274-92. PubMed ID: 20300847
[TBL] [Abstract][Full Text] [Related]
17. Intra-aneurysmal hemodynamic alterations by a self-expandable intracranial stent and flow diversion stent: high intra-aneurysmal pressure remains regardless of flow velocity reduction.
Shobayashi Y; Tateshima S; Kakizaki R; Sudo R; Tanishita K; Viñuela F
J Neurointerv Surg; 2013 Nov; 5 Suppl 3():iii38-42. PubMed ID: 23048176
[TBL] [Abstract][Full Text] [Related]
18. Impact of stents and flow diverters on hemodynamics in idealized aneurysm models.
Seshadhri S; Janiga G; Beuing O; Skalej M; Thévenin D
J Biomech Eng; 2011 Jul; 133(7):071005. PubMed ID: 21823744
[TBL] [Abstract][Full Text] [Related]
19. Computational fluid dynamics with stents: quantitative comparison with particle image velocimetry for three commercial off the shelf intracranial stents.
Bouillot P; Brina O; Ouared R; Yilmaz H; Lovblad KO; Farhat M; Mendes Pereira V
J Neurointerv Surg; 2016 Mar; 8(3):309-15. PubMed ID: 25603807
[TBL] [Abstract][Full Text] [Related]
20. Hemodynamic changes due to stent placement in bifurcating intracranial aneurysms.
Cantón G; Levy DI; Lasheras JC
J Neurosurg; 2005 Jul; 103(1):146-55. PubMed ID: 16121985
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]