These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

130 related articles for article (PubMed ID: 25227268)

  • 21. A formula to calculate the contrast volume required for optimal imaging quality in optical coherence tomography with non-occlusive technique.
    Gutiérrez-Chico JL; Cortés C; Schincariol M; Jaguszewski M
    Cardiol J; 2018; 25(5):574-581. PubMed ID: 30246237
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Relative dependence of diameters of branches in coronary bifurcations after stent implantation in main vessel--importance of carina position.
    Vassilev D; Gil RJ
    Kardiol Pol; 2008 Apr; 66(4):371-8; discussion 379. PubMed ID: 18473265
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Inter-scan reproducibility of geometric coronary artery measurements using frequency-domain optical coherence tomography.
    Orii M; Kubo T; Tanaka A; Kitabata H; Ino Y; Shiono Y; Shimamura K; Aoki H; Ohta S; Ozaki Y; Ishibashi K; Yamano T; Tanimoto T; Yamaguchi T; Hirata K; Imanishi T; Akasaka T
    Int Heart J; 2013; 54(2):64-7. PubMed ID: 23676364
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Automatic Side Branch Ostium Detection and Main Vascular Segmentation in Intravascular Optical Coherence Tomography Images.
    Cao Y; Jin Q; Chen Y; Yin Q; Qin X; Li J; Zhu R; Zhao W
    IEEE J Biomed Health Inform; 2018 Sep; 22(5):1531-1539. PubMed ID: 29990134
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Intravascular ultrasound and 3D angle measurements of coronary bifurcations.
    van der Waal EC; Mintz GS; Garcia-Garcia HM; Bui AB; Pehlivanova M; Girasis C; Serruys PW; van der Giessen WJ; Weissman NJ
    Catheter Cardiovasc Interv; 2009 Jun; 73(7):910-6. PubMed ID: 19301356
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Assessment with optical coherence tomography of a new strategy for bifurcational lesion treatment: the Tryton Side-Branch Stent.
    Ferrante G; Kaplan AV; Di Mario C
    Catheter Cardiovasc Interv; 2009 Jan; 73(1):69-72. PubMed ID: 19089962
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Branch ostial optimization treatment and optimized provisional t-stenting with polymeric bioresorbable scaffolds: Ex-vivo morphologic and hemodynamic examination.
    Cai W; Chen L; Zhang L; Tu S; Fan L; Chen Z; Luo Y; Zheng X
    Medicine (Baltimore); 2018 Oct; 97(43):e12972. PubMed ID: 30412122
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Efficacy of a new generation intracoronary optical coherence tomography imaging system with fast pullback.
    Nishi T; Kume T; Yamada R; Koto S; Sasahira Y; Okamoto H; Tamada T; Koyama T; Imai K; Neishi Y; Ughi GJ; Uemura S
    Catheter Cardiovasc Interv; 2023 Feb; 101(3):520-527. PubMed ID: 36740230
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Serial assessment of vessel interactions after drug-eluting stent implantation in unprotected distal left main coronary artery disease using frequency-domain optical coherence tomography.
    Fujino Y; Attizzani GF; Bezerra HG; Wang W; Tahara S; Yamamoto H; Chamie D; Kanaya T; Mehanna E; Takagi K; Nakamura S; Costa MA
    JACC Cardiovasc Interv; 2013 Oct; 6(10):1035-45. PubMed ID: 24156964
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Elliptical stretch as a cause of side branch ostial compromise after main vessel stenting in coronary bifurcations: New insights from numerical analysis.
    Vassilev DI; Kassab GS; Collet C; Gutiérrez-Chico JL; Rigatelli G; Gil RJ; Serruys PW
    Cardiol J; 2020; 27(5):507-517. PubMed ID: 30394509
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Healing responses after bifurcation stenting with the dedicated TRYTON Side-Branch Stent™ in combination with XIENCE-V™ stents: a clinical, angiography, fractional flow reserve, and optical coherence tomography study: the PYTON (Prospective evaluation of the TRYTON Side-Branch Stent™ with an additional XIENCE-v™ everolimus-eluting stent in coronary bifurcation lesions) study.
    Dubois C; Adriaenssens T; Ughi G; Wiyono S; Bennett J; Coosemans M; Ferdinande B; Sinnaeve P; D'hooge J; Desmet W
    Catheter Cardiovasc Interv; 2013 Feb; 81(3):E155-64. PubMed ID: 22745031
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Randomized comparison of conservative versus aggressive strategy for provisional side branch intervention in coronary bifurcation lesions: results from the SMART-STRATEGY (Smart Angioplasty Research Team-Optimal Strategy for Side Branch Intervention in Coronary Bifurcation Lesions) randomized trial.
    Song YB; Hahn JY; Song PS; Yang JH; Choi JH; Choi SH; Lee SH; Gwon HC
    JACC Cardiovasc Interv; 2012 Nov; 5(11):1133-40. PubMed ID: 23174637
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Risk Assessment of Side Branch Compromise After Coronary Bifurcation Stenting - A Substudy of the 3D-OCT Bifurcation Registry.
    Akase H; Okamura T; Nagoshi R; Fujimura T; Miyazaki Y; Takenaka H; Matsuyama T; Murasato Y; Yamawaki M; Ono S; Serikawa T; Hikichi Y; Norita H; Nakao F; Sakamoto T; Shinke T; Yano M; Shite J
    Circ J; 2024 May; 88(6):959-969. PubMed ID: 37839862
    [TBL] [Abstract][Full Text] [Related]  

  • 34. An assessment of the quality of optical coherence tomography image acquisition.
    Iarossi Zago E; Samdani AJ; Pereira GTR; Vergara-Martel A; Alaiti MA; Dallan LA; Ely Pizzato P; Zimin V; Fares A; Bezerra HG
    Int J Cardiovasc Imaging; 2020 Jun; 36(6):1013-1020. PubMed ID: 32072443
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Frequency domain optical coherence tomography to assess non-ostial left main coronary artery.
    Burzotta F; Dato I; Trani C; Pirozzolo G; De Maria GL; Porto I; Niccoli G; Leone AM; Schiavoni G; Crea F
    EuroIntervention; 2015 Jan; 10(9):e1-8. PubMed ID: 25599698
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Comparison of diagnostic performance in assessing the rewiring position into a jailed side branch between online 3D reconstruction systems version 1.1 and 1.2 derived from optical frequency domain imaging.
    Fujimura T; Okamura T; Furuya K; Miyazaki Y; Takenaka H; Tateishi H; Oda T; Mochizuki M; Uchinoumi H; Nishimura T; Yamada J; Yano M
    Cardiovasc Interv Ther; 2020 Oct; 35(4):336-342. PubMed ID: 31707692
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Co-registration of optical coherence tomography and X-ray angiography in percutaneous coronary intervention. the Does Optical Coherence Tomography Optimize Revascularization (DOCTOR) fusion study.
    Hebsgaard L; Nielsen TM; Tu S; Krusell LR; Maeng M; Veien KT; Raungaard B; Terkelsen CJ; Kaltoft A; Reiber JH; Lassen JF; Christiansen EH; Holm NR
    Int J Cardiol; 2015 Mar; 182():272-8. PubMed ID: 25585362
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Influence of parent vessel - side branch distal angle on restenosis rates after main vessel stenting in coronary bifurcation lesion.
    Gil RJ; Vassilev D; Rzezak J; Słysz A; Krzyzewski R; Kulawik T
    Kardiol Pol; 2009 Jan; 67(1):36-43; discussion 44-5. PubMed ID: 19253188
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Impact of frequency-domain optical coherence tomography guidance for optimal coronary stent implantation in comparison with intravascular ultrasound guidance.
    Habara M; Nasu K; Terashima M; Kaneda H; Yokota D; Ko E; Ito T; Kurita T; Tanaka N; Kimura M; Ito T; Kinoshita Y; Tsuchikane E; Asakura K; Asakura Y; Katoh O; Suzuki T
    Circ Cardiovasc Interv; 2012 Apr; 5(2):193-201. PubMed ID: 22456026
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Fully automatic three-dimensional quantitative analysis of intracoronary optical coherence tomography: method and Validation.
    Sihan K; Botha C; Post F; de Winter S; Gonzalo N; Regar E; Serruys PJ; Hamers R; Bruining N
    Catheter Cardiovasc Interv; 2009 Dec; 74(7):1058-65. PubMed ID: 19521990
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 7.