BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

502 related articles for article (PubMed ID: 25230263)

  • 21. LCP metaphyseal plate fixation for fractures of the distal third humeral shaft using brachialis splitting approach.
    Lee SK; Yang DS; Chang SH; Choy WS
    Acta Orthop Belg; 2016 Mar; 82(1):85-93. PubMed ID: 26984659
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Minimally invasive plating for complex humeral shaft fractures.
    Jiang R; Luo CF; Zeng BF; Mei GH
    Arch Orthop Trauma Surg; 2007 Sep; 127(7):531-5. PubMed ID: 17401571
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Minimally invasive plate osteosynthesis using a locking compression plate for diaphyseal humeral fractures.
    Malhan S; Thomas S; Srivastav S; Agarwal S; Mittal V; Nadkarni B; Gulati D
    J Orthop Surg (Hong Kong); 2012 Dec; 20(3):292-6. PubMed ID: 23255632
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Minimally invasive plate osteosynthesis of humeral shaft fractures: a technique to aid fracture reduction and minimize complications.
    Shin SJ; Sohn HS; Do NH
    J Orthop Trauma; 2012 Oct; 26(10):585-9. PubMed ID: 22534690
    [TBL] [Abstract][Full Text] [Related]  

  • 25. [Functional results after osteosynthesis of the distal humerus fracture with an anatomically precontoured, angular-stable double plate system].
    Schmidt-Horlohé K; Bonk A; Wilde P; Becker L; Hoffmann R
    Z Orthop Unfall; 2010 May; 148(3):300-8. PubMed ID: 20135617
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Shoulder function after surgical treatment of displaced fractures of the humeral shaft: a randomized trial comparing antegrade intramedullary nailing with minimally invasive plate osteosynthesis.
    Benegas E; Ferreira Neto AA; Gracitelli ME; Malavolta EA; Assunção JH; Prada Fde S; Bolliger Neto R; Mattar R
    J Shoulder Elbow Surg; 2014 Jun; 23(6):767-74. PubMed ID: 24768221
    [TBL] [Abstract][Full Text] [Related]  

  • 27. [Treatment of humerus shaft fractures using minimally invasive percutaneous plate osteosynthesis through anterior approach].
    Wang ZH; Xiang M; Xie J; Tang HC; Chen H; Liu X
    Zhongguo Gu Shang; 2009 Sep; 22(9):681-3. PubMed ID: 19817201
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Minimally invasive plate osteosynthesis for proximal humerus fractures: functional results of treatment.
    Altman GT; Gallo RA; Molinero KG; Muffly MT; Mascarenhas L
    Am J Orthop (Belle Mead NJ); 2011 Mar; 40(3):E40-7. PubMed ID: 21720607
    [TBL] [Abstract][Full Text] [Related]  

  • 29. [Effectiveness comparison of two minimally invasive plate osteosynthesis techniques for proximal humeral shaft fractures].
    Wang X; Sun K; Tang L; Liang B; Yin D
    Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi; 2023 Feb; 37(2):147-152. PubMed ID: 36796807
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Open reduction and fixation with a locking plate without bone grafting is a reasonable and safe option for treating proximal humerus nonunion.
    Quadlbauer S; Hofmann GJ; Leixnering M; Rosenauer R; Hausner T; Reichetseder J
    Int Orthop; 2018 Sep; 42(9):2199-2209. PubMed ID: 29442159
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Minimally invasive lateral plating for diaphyseal fractures with extension into the proximal humerus and its implications for the deltoid muscle and its distal insertion: functional analysis and MR-imaging.
    Flury D; Metzler C; Rauch S; Schläppi M; Benninger E; Meier C
    BMC Musculoskelet Disord; 2023 Nov; 24(1):867. PubMed ID: 37936156
    [TBL] [Abstract][Full Text] [Related]  

  • 32. [Treatment of mid-distal humeral shaft fractures associated with radial nerve palsy using minimally invasive plating osteosynthesis technique].
    An Z; Zeng B; He X; Huang P
    Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi; 2008 May; 22(5):513-5. PubMed ID: 18630424
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Lessons learned from treating patients with unstable multifragmentary fractures of the proximal humerus by minimal invasive plate osteosynthesis.
    Oh HK; Cho DY; Choo SK; Park JW; Park KC; Lee JI
    Arch Orthop Trauma Surg; 2015 Feb; 135(2):235-242. PubMed ID: 25552395
    [TBL] [Abstract][Full Text] [Related]  

  • 34. One-third tubular-hook-plate osteosynthesis for olecranon osteotomies in distal humerus type-C fractures: a preliminary report of results and complications.
    Schmidt-Horlohé K; Wilde P; Bonk A; Becker L; Hoffmann R
    Injury; 2012 Mar; 43(3):295-300. PubMed ID: 21782172
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Early full range of shoulder and elbow motion is possible after minimally invasive plate osteosynthesis for humeral shaft fractures.
    Kobayashi M; Watanabe Y; Matsushita T
    J Orthop Trauma; 2010 Apr; 24(4):212-6. PubMed ID: 20335753
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Surgical result of plate osteosynthesis using a locking plate system through an anterior humeral approach for distal shaft fracture of the humerus that occurred during a throwing motion.
    Kim SJ; Lee SH; Son H; Lee BG
    Int Orthop; 2016 Jul; 40(7):1489-94. PubMed ID: 26202018
    [TBL] [Abstract][Full Text] [Related]  

  • 37. [Minimally invasive percutaneous plate osteosynthesis technique for treatment of Neer II, III parts fracture of proximal humerus].
    Jiang P; Wei P; Chen L; Xia X
    Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi; 2011 Nov; 25(11):1330-4. PubMed ID: 22229187
    [TBL] [Abstract][Full Text] [Related]  

  • 38. [Case-control study on close manipulative reduction combined with minimally invasive percutaneous plate fixation for the treatment of proximal humeral fractures].
    Liu YW; Wei XE; Gao NY; Li ZQ; Kuang Y; Zhan HS; Shi YY; Zheng YX
    Zhongguo Gu Shang; 2014 Apr; 27(4):311-5. PubMed ID: 25029840
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Outcomes following distal humeral fracture fixation with an extensor mechanism-on approach.
    Erpelding JM; Mailander A; High R; Mormino MA; Fehringer EV
    J Bone Joint Surg Am; 2012 Mar; 94(6):548-53. PubMed ID: 22438004
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Comparison between minimally invasive, percutaneous osteosynthesis and locking plate osteosynthesis in 3-and 4-part proximal humerus fractures.
    Ortmaier R; Filzmaier V; Hitzl W; Bogner R; Neubauer T; Resch H; Auffarth A
    BMC Musculoskelet Disord; 2015 Oct; 16():297. PubMed ID: 26467533
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 26.