These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

363 related articles for article (PubMed ID: 25230862)

  • 1. [The assessment of ultrasonic measurement of superior vena cava blood flow for the volume responsiveness of patients with mechanical ventilation].
    Guo Z; He W; Hou J; Li T; Zhou H; Xu Y; Xi X
    Zhonghua Wei Zhong Bing Ji Jiu Yi Xue; 2014 Sep; 26(9):624-8. PubMed ID: 25230862
    [TBL] [Abstract][Full Text] [Related]  

  • 2. [Measurement of brachial artery velocity variation and inferior vena cava variability to estimate fluid responsiveness].
    Zhu W; Wan L; Wan X; Wang G; Su M; Liao G; Huang Q
    Zhonghua Wei Zhong Bing Ji Jiu Yi Xue; 2016 Aug; 28(8):713-7. PubMed ID: 27434562
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Respiratory Variation in Aortic Blood Flow Velocity in Hemodynamically Unstable, Ventilated Neonates: A Pilot Study of Fluid Responsiveness.
    Oulego-Erroz I; Terroba-Seara S; Alonso-Quintela P; Rodríguez-Núñez A
    Pediatr Crit Care Med; 2021 Apr; 22(4):380-391. PubMed ID: 33315755
    [TBL] [Abstract][Full Text] [Related]  

  • 4. [Variability of peripheral arterial peak velocity predicts fluid responsiveness in patients with septic shock].
    Lu N; Jiang L; Zhu B; Han W; Zhao Y; Shi Y; Guo F; Xi X
    Zhonghua Wei Zhong Bing Ji Jiu Yi Xue; 2018 Mar; 30(3):224-229. PubMed ID: 29519280
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Low predictability of three different noninvasive methods to determine fluid responsiveness in critically ill children.
    Weber T; Wagner T; Neumann K; Deusch E
    Pediatr Crit Care Med; 2015 Mar; 16(3):e89-94. PubMed ID: 25647238
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Comparison between respiratory changes in the inferior vena cava diameter and pulse pressure variation to predict fluid responsiveness in postoperative patients.
    de Oliveira OH; Freitas FG; Ladeira RT; Fischer CH; Bafi AT; Azevedo LC; Machado FR
    J Crit Care; 2016 Aug; 34():46-9. PubMed ID: 27288609
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Respiratory variation in aortic blood peak velocity and caudal vena cava diameter can predict fluid responsiveness in anaesthetised and mechanically ventilated dogs.
    Bucci M; Rabozzi R; Guglielmini C; Franci P
    Vet J; 2017 Sep; 227():30-35. PubMed ID: 29031327
    [TBL] [Abstract][Full Text] [Related]  

  • 8. [The value of passive leg raising test in predicting fluid responsiveness in patients with sepsis-induced cardiac dysfunction].
    Xiang S; Muyun H; Juan C; Bin O; Minying C; Changjie C; Jianfeng W; Zimeng L; Yongjun L; Shunwei H; Lifen L; Xiangdong G
    Zhonghua Wei Zhong Bing Ji Jiu Yi Xue; 2015 Sep; 27(9):729-34. PubMed ID: 26955698
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Respiratory variation in peak aortic velocity accurately predicts fluid responsiveness in children undergoing neurosurgery under general anesthesia.
    Morparia KG; Reddy SK; Olivieri LJ; Spaeder MC; Schuette JJ
    J Clin Monit Comput; 2018 Apr; 32(2):221-226. PubMed ID: 28299589
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Respirophasic carotid artery peak velocity variation as a predictor of fluid responsiveness in mechanically ventilated patients with coronary artery disease.
    Song Y; Kwak YL; Song JW; Kim YJ; Shim JK
    Br J Anaesth; 2014 Jul; 113(1):61-6. PubMed ID: 24722322
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Inferior vena cava diameter variation compared with pulse pressure variation as predictors of fluid responsiveness in patients with sepsis.
    Theerawit P; Morasert T; Sutherasan Y
    J Crit Care; 2016 Dec; 36():246-251. PubMed ID: 27591389
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Respiratory Variability of Pulmonary Velocity-Time Integral As a New Gauge of Fluid Responsiveness For Mechanically Ventilated Patients in the ICU.
    Gavaud A; Nguyen LS; Caubel A; Grillet G; Donal E; Belliard G
    Crit Care Med; 2019 Apr; 47(4):e310-e316. PubMed ID: 30664525
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Predicting preload responsiveness using simultaneous recordings of inferior and superior vena cavae diameters.
    Charbonneau H; Riu B; Faron M; Mari A; Kurrek MM; Ruiz J; Geeraerts T; Fourcade O; Genestal M; Silva S
    Crit Care; 2014 Sep; 18(5):473. PubMed ID: 25189403
    [TBL] [Abstract][Full Text] [Related]  

  • 14. The value of a superior vena cava collapsibility index measured with a miniaturized transoesophageal monoplane continuous echocardiography probe to predict fluid responsiveness compared to stroke volume variations in open major vascular surgery: a prospective cohort study.
    Bubenek-Turconi ŞI; Hendy A; Băilă S; Drăgan A; Chioncel O; Văleanu L; Moroșanu B; Iliescu VA
    J Clin Monit Comput; 2020 Jun; 34(3):491-499. PubMed ID: 31278544
    [TBL] [Abstract][Full Text] [Related]  

  • 15. An increase in aortic blood flow after an infusion of 100 ml colloid over 1 minute can predict fluid responsiveness: the mini-fluid challenge study.
    Muller L; Toumi M; Bousquet PJ; Riu-Poulenc B; Louart G; Candela D; Zoric L; Suehs C; de La Coussaye JE; Molinari N; Lefrant JY;
    Anesthesiology; 2011 Sep; 115(3):541-7. PubMed ID: 21792056
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Comparison of superior and inferior vena cava diameter variation measured with transthoracic echocardiography to predict fluid responsiveness in mechanically ventilated patients after abdominal surgery.
    Ma Q; Ji J; Shi X; Lu Z; Xu L; Hao J; Zhu W; Li B
    BMC Anesthesiol; 2022 May; 22(1):150. PubMed ID: 35581547
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Accuracy of Respiratory Variation in Inferior Vena Cava Diameter to Predict Fluid Responsiveness in Children Under Mechanical Ventilation.
    Campos NB; de Lima LB; Ferraz IS; Nogueira RJN; Brandão MB; de Souza TH
    Pediatr Cardiol; 2024 Aug; 45(6):1326-1333. PubMed ID: 36759350
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Ultrasonographic measurement of the respiratory variation in the inferior vena cava diameter is predictive of fluid responsiveness in critically ill patients: systematic review and meta-analysis.
    Zhang Z; Xu X; Ye S; Xu L
    Ultrasound Med Biol; 2014 May; 40(5):845-53. PubMed ID: 24495437
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Evaluation of volume responsiveness by pulse pressure variability and inferior vena cava dispensability index at different tidal volumes by mechanical ventilation.
    He F; Li X; Thapa S; Li C; Luo J; Dai W; Liu J
    Braz J Med Biol Res; 2019; 52(9):e8827. PubMed ID: 31482978
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Efficacy of using tidal volume challenge to improve the reliability of pulse pressure variation reduced in low tidal volume ventilated critically ill patients with decreased respiratory system compliance.
    Xu Y; Guo J; Wu Q; Chen J
    BMC Anesthesiol; 2022 May; 22(1):137. PubMed ID: 35508962
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 19.