119 related articles for article (PubMed ID: 25236764)
21. Automated segmentation of myocardial scar in late enhancement MRI using combined intensity and spatial information.
Tao Q; Milles J; Zeppenfeld K; Lamb HJ; Bax JJ; Reiber JH; van der Geest RJ
Magn Reson Med; 2010 Aug; 64(2):586-94. PubMed ID: 20665801
[TBL] [Abstract][Full Text] [Related]
22. High spatial resolution free-breathing 3D late gadolinium enhancement cardiac magnetic resonance imaging in ischaemic and non-ischaemic cardiomyopathy: quantitative assessment of scar mass and image quality.
Bizino MB; Tao Q; Amersfoort J; Siebelink HJ; van den Bogaard PJ; van der Geest RJ; Lamb HJ
Eur Radiol; 2018 Sep; 28(9):4027-4035. PubMed ID: 29626239
[TBL] [Abstract][Full Text] [Related]
23. An improved real-time cine Late Gadolinium Enhancement (LGE) imaging method at 3T.
Kadbi M; Kotys M; Alshaher M; Fischer S; Amini AA
Annu Int Conf IEEE Eng Med Biol Soc; 2011; 2011():531-4. PubMed ID: 22254365
[TBL] [Abstract][Full Text] [Related]
24. Acute, subacute, and chronic myocardial infarction: quantitative comparison of 2D and 3D late gadolinium enhancement MR imaging.
Goetti R; Kozerke S; Donati OF; Sürder D; Stolzmann P; Kaufmann PA; Lüscher TF; Corti R; Manka R
Radiology; 2011 Jun; 259(3):704-11. PubMed ID: 21467254
[TBL] [Abstract][Full Text] [Related]
25. Validation of sub-segmental visual scoring for the quantification of ischemic and nonischemic myocardial fibrosis using late gadolinium enhancement MRI.
Fine NM; Tandon S; Kim HW; Shah DJ; Thompson T; Drangova M; White JA
J Magn Reson Imaging; 2013 Dec; 38(6):1369-76. PubMed ID: 23559419
[TBL] [Abstract][Full Text] [Related]
26. 3D delayed-enhanced magnetic resonance sequences improve conducting channel delineation prior to ventricular tachycardia ablation.
Andreu D; Ortiz-Pérez JT; Fernández-Armenta J; Guiu E; Acosta J; Prat-González S; De Caralt TM; Perea RJ; Garrido C; Mont L; Brugada J; Berruezo A
Europace; 2015 Jun; 17(6):938-45. PubMed ID: 25616406
[TBL] [Abstract][Full Text] [Related]
27. Left ventricular infarct size, peri-infarct zone, and papillary scar measurements: A comparison of high-resolution 3D and conventional 2D late gadolinium enhancement cardiac MR.
Peters DC; Appelbaum EA; Nezafat R; Dokhan B; Han Y; Kissinger KV; Goddu B; Manning WJ
J Magn Reson Imaging; 2009 Oct; 30(4):794-800. PubMed ID: 19787731
[TBL] [Abstract][Full Text] [Related]
28. Three-dimensional segmentation of the left ventricle in late gadolinium enhanced MR images of chronic infarction combining long- and short-axis information.
Wei D; Sun Y; Ong SH; Chai P; Teo LL; Low AF
Med Image Anal; 2013 Aug; 17(6):685-97. PubMed ID: 23562069
[TBL] [Abstract][Full Text] [Related]
29. Comparison of semi-automated scar quantification techniques using high-resolution, 3-dimensional late-gadolinium-enhancement magnetic resonance imaging.
Rajchl M; Stirrat J; Goubran M; Yu J; Scholl D; Peters TM; White JA
Int J Cardiovasc Imaging; 2015 Feb; 31(2):349-57. PubMed ID: 25307896
[TBL] [Abstract][Full Text] [Related]
30. Improvement of late gadolinium enhancement image quality using a deep learning-based reconstruction algorithm and its influence on myocardial scar quantification.
van der Velde N; Hassing HC; Bakker BJ; Wielopolski PA; Lebel RM; Janich MA; Kardys I; Budde RPJ; Hirsch A
Eur Radiol; 2021 Jun; 31(6):3846-3855. PubMed ID: 33219845
[TBL] [Abstract][Full Text] [Related]
31. Late gadolinium enhancement in the assessment of the infarcted mouse heart: a longitudinal comparison with manganese-enhanced MRI.
Skårdal K; Rolim NP; Haraldseth O; Goa PE; Thuen M
J Magn Reson Imaging; 2013 Dec; 38(6):1388-94. PubMed ID: 23559475
[TBL] [Abstract][Full Text] [Related]
32. Right atrial scar detection after catheter ablation: Comparison of 2D and high spatial resolution 3D-late enhancement magnetic resonance imaging.
Ozgun M; Maintz D; Bunck AC; Mönnig G; Eckardt L; Wasmer K; Heindel W; Botnar RM; Kirchhof P
Acad Radiol; 2011 Apr; 18(4):488-94. PubMed ID: 21277233
[TBL] [Abstract][Full Text] [Related]
33. Myocardial scar identification based on analysis of Look-Locker and 3D late gadolinium enhanced MRI.
Tao Q; Lamb HJ; Zeppenfeld K; van der Geest RJ
Int J Cardiovasc Imaging; 2014 Jun; 30(5):925-34. PubMed ID: 24643328
[TBL] [Abstract][Full Text] [Related]
34. High spatial resolution, respiratory-gated, t1-weighted magnetic resonance imaging of the liver and the biliary tract during the hepatobiliary phase of gadoxetic Acid-enhanced magnetic resonance imaging.
Lee ES; Lee JM; Yu MH; Shin CI; Woo HS; Joo I; Stemmer A; Han JK; Choi BI
J Comput Assist Tomogr; 2014; 38(3):360-6. PubMed ID: 24681858
[TBL] [Abstract][Full Text] [Related]
35. Incorporation of view sharing and KWIC filtering into GRASP-Pro improves spatial resolution of single-shot, multi-TI, late gadolinium enhancement MRI.
Zhao M; Shen D; Fan L; Hong K; Feng L; Benefield BC; Allen BD; Lee DC; Kim D
NMR Biomed; 2024 Mar; 37(3):e5059. PubMed ID: 37872862
[TBL] [Abstract][Full Text] [Related]
36. Isotropic reconstruction of a 4-D MRI thoracic sequence using super-resolution.
Van Reeth E; Tan CH; Tham IW; Poh CL
Magn Reson Med; 2015 Feb; 73(2):784-93. PubMed ID: 24478231
[TBL] [Abstract][Full Text] [Related]
37. Pharmacokinetic modeling of delayed gadolinium enhancement in the myocardium.
Knowles BR; Batchelor PG; Parish V; Ginks M; Plein S; Razavi R; Schaeffter T
Magn Reson Med; 2008 Dec; 60(6):1524-30. PubMed ID: 19025896
[TBL] [Abstract][Full Text] [Related]
38. Extent of MRI delayed enhancement of myocardial mass is related to right ventricular dysfunction in pulmonary artery hypertension.
McCann GP; Gan CT; Beek AM; Niessen HW; Vonk Noordegraaf A; van Rossum AC
AJR Am J Roentgenol; 2007 Feb; 188(2):349-55. PubMed ID: 17242241
[TBL] [Abstract][Full Text] [Related]
39. Head-to-head comparison of contrast-enhanced magnetic resonance imaging and electroanatomical voltage mapping to assess post-infarct scar characteristics in patients with ventricular tachycardias: real-time image integration and reversed registration.
Wijnmaalen AP; van der Geest RJ; van Huls van Taxis CF; Siebelink HM; Kroft LJ; Bax JJ; Reiber JH; Schalij MJ; Zeppenfeld K
Eur Heart J; 2011 Jan; 32(1):104-14. PubMed ID: 20864488
[TBL] [Abstract][Full Text] [Related]
40. Wideband late gadolinium enhanced magnetic resonance imaging for imaging myocardial scar without image artefacts induced by implantable cardioverter-defibrillator: a feasibility study at 3 T.
Ranjan R; McGann CJ; Jeong EK; Hong K; Kholmovski EG; Blauer J; Wilson BD; Marrouche NF; Kim D
Europace; 2015 Mar; 17(3):483-8. PubMed ID: 25336666
[TBL] [Abstract][Full Text] [Related]
[Previous] [Next] [New Search]