These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

145 related articles for article (PubMed ID: 25241214)

  • 1. Monopolar electromyographic signals recorded by a current amplifier in air and under water without insulation.
    Whitting JW; von Tscharner V
    J Electromyogr Kinesiol; 2014 Dec; 24(6):848-54. PubMed ID: 25241214
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Analysis of various conditions in order to measure electromyography of isometric contractions in water and on air.
    Carvalho RG; Amorim CF; Perácio LH; Coelho HF; Vieira AC; Karl Menzel HJ; Szmuchrowski LA
    J Electromyogr Kinesiol; 2010 Oct; 20(5):988-93. PubMed ID: 20385505
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Surface EMG alterations induced by underwater recording.
    Rainoldi A; Cescon C; Bottin A; Casale R; Caruso I
    J Electromyogr Kinesiol; 2004 Jun; 14(3):325-31. PubMed ID: 15094146
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Comparison of electromyographic signals from monopolar current and potential amplifiers derived from a penniform muscle, the gastrocnemius medialis.
    von Tscharner V; Maurer C; Ruf F; Nigg BM
    J Electromyogr Kinesiol; 2013 Oct; 23(5):1044-51. PubMed ID: 23938250
    [TBL] [Abstract][Full Text] [Related]  

  • 5. A novel signal processing method using system identification for underwater surface electromyography.
    Uehara S; Muraoka Y; Tanabe S; Ota T; Kimura A
    Electromyogr Clin Neurophysiol; 2009; 49(2-3):103-8. PubMed ID: 19400405
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Does local immersion in thermo-neutral bath influence surface EMG measurements? Results of an experimental trial.
    Kalpakcioglu B; Candir F; Bernateck M; Gutenbrunner C; Fischer MJ
    J Electromyogr Kinesiol; 2009 Dec; 19(6):e550-3. PubMed ID: 19028430
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Human isometric force production and electromyogram activity of knee extensor muscles in water and on dry land.
    Pöyhönen T; Keskinen KL; Hautala A; Savolainen J; Mälkiä E
    Eur J Appl Physiol Occup Physiol; 1999 Jun; 80(1):52-6. PubMed ID: 10367723
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Confounding factors in water EMG recordings: an approach to a definitive standard.
    Veneziano WH; da Rocha AF; Gonçalves CA; Pena AG; Carmo JC; Nascimento FA; Rainoldi A
    Med Biol Eng Comput; 2006 Apr; 44(4):348-51. PubMed ID: 16937176
    [TBL] [Abstract][Full Text] [Related]  

  • 9. The effects of interelectrode distance on electromyographic amplitude and mean power frequency during isokinetic and isometric muscle actions of the biceps brachii.
    Beck TW; Housh TJ; Johnson GO; Weir JP; Cramer JT; Coburn JW; Malek MH
    J Electromyogr Kinesiol; 2005 Oct; 15(5):482-95. PubMed ID: 15935960
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Muscle temperature and EMG amplitude and frequency during isometric exercise.
    Petrofsky J; Laymon M
    Aviat Space Environ Med; 2005 Nov; 76(11):1024-30. PubMed ID: 16313138
    [TBL] [Abstract][Full Text] [Related]  

  • 11. An examination of the linearity and reliability of the electromyographic amplitude versus dynamic constant external resistance relationships using monopolar and bipolar recording methods.
    Stock MS; Beck TW; Defreitas JM; Dillon MA
    J Neurosci Methods; 2010 Dec; 194(1):94-101. PubMed ID: 20888861
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Time and frequency domain responses of the mechanomyogram and electromyogram during isometric ramp contractions: a comparison of the short-time Fourier and continuous wavelet transforms.
    Ryan ED; Cramer JT; Egan AD; Hartman MJ; Herda TJ
    J Electromyogr Kinesiol; 2008 Feb; 18(1):54-67. PubMed ID: 17070700
    [TBL] [Abstract][Full Text] [Related]  

  • 13. An EMG-CT method using multiple surface electrodes in the forearm.
    Nakajima Y; Keeratihattayakorn S; Yoshinari S; Tadano S
    J Electromyogr Kinesiol; 2014 Dec; 24(6):875-80. PubMed ID: 25156447
    [TBL] [Abstract][Full Text] [Related]  

  • 14. The effects of parallel versus perpendicular electrode orientations on EMG amplitude and mean power frequency from the biceps brachii.
    Zuniga J; Housh TJ; Camic CL; Hendrix CR; Mielke M; Schmidt RJ; Johnson GO
    Electromyogr Clin Neurophysiol; 2010 Mar; 50(2):87-96. PubMed ID: 20405784
    [TBL] [Abstract][Full Text] [Related]  

  • 15. A comparison of surface and fine wire EMG recordings of gluteus medius during selected maximum isometric voluntary contractions of the hip.
    Semciw AI; Neate R; Pizzari T
    J Electromyogr Kinesiol; 2014 Dec; 24(6):835-40. PubMed ID: 25245248
    [TBL] [Abstract][Full Text] [Related]  

  • 16. An electromyographic volley at initiation of rapid isometric contractions of the elbow.
    Yamazaki Y; Suzuki M; Mano T
    Brain Res Bull; 1993; 30(1-2):181-7. PubMed ID: 8420629
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Local muscle endurance is associated with fatigue-based changes in electromyographic spectral properties, but not with conduction velocity.
    Beck TW; Ye X; Wages NP
    J Electromyogr Kinesiol; 2015 Jun; 25(3):451-6. PubMed ID: 25744086
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Comparison between the degree of motor unit short-term synchronization and recurrence quantification analysis of the surface EMG in two human muscles.
    Dideriksen JL; Falla D; Bækgaard M; Mogensen ML; Steimle KL; Farina D
    Clin Neurophysiol; 2009 Dec; 120(12):2086-2092. PubMed ID: 19828371
    [TBL] [Abstract][Full Text] [Related]  

  • 19. High-pass filtering surface EMG in an attempt to better represent the signals detected at the intramuscular level.
    Brown SH; Brookham RL; Dickerson CR
    Muscle Nerve; 2010 Feb; 41(2):234-9. PubMed ID: 19722252
    [TBL] [Abstract][Full Text] [Related]  

  • 20. The effects of interelectrode distance over the innervation zone and normalization on the electromyographic amplitude and mean power frequency versus concentric, eccentric, and isometric torque relationships for the vastus lateralis muscle.
    Beck TW; Housh TJ; Cramer JT; Weir JP
    J Electromyogr Kinesiol; 2009 Apr; 19(2):219-31. PubMed ID: 17884581
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]