These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
6. Highly crosslinked polyethylene does not reduce the wear in total knee arthroplasty: in vivo study of particles in synovial fluid. Hinarejos P; Piñol I; Torres A; Prats E; Gil-Gómez G; Puig-Verdie L J Arthroplasty; 2013 Sep; 28(8):1333-7. PubMed ID: 23507066 [TBL] [Abstract][Full Text] [Related]
7. Challenges associated with using bovine serum in wear testing orthopaedic biopolymers. Harsha AP; Joyce TJ Proc Inst Mech Eng H; 2011 Oct; 225(10):948-58. PubMed ID: 22204117 [TBL] [Abstract][Full Text] [Related]
8. Commissioning of a displacement-controlled knee wear simulator and exploration of some issues related to the lubricant. Brandt JM; Charron KD; Zhao L; MacDonald SJ; Medley JB Proc Inst Mech Eng H; 2011 Aug; 225(8):736-52. PubMed ID: 21922951 [TBL] [Abstract][Full Text] [Related]
9. Measures for reducing ultra-high-molecular-weight polyethylene wear in total knee replacement: a simulator study. Mueller-Rath R; Kleffner B; Andereya S; Mumme T; Wirtz DC Biomed Tech (Berl); 2007 Aug; 52(4):295-300. PubMed ID: 17691863 [TBL] [Abstract][Full Text] [Related]
10. Investigation of wear of knee prostheses in a new displacement/force-controlled simulator. Barnett PI; McEwen HM; Auger DD; Stone MH; Ingham E; Fisher J Proc Inst Mech Eng H; 2002; 216(1):51-61. PubMed ID: 11908483 [TBL] [Abstract][Full Text] [Related]
11. Vitamin E-infused highly cross-linked polyethylene did not reduce the number of in vivo wear particles in total knee arthroplasty. Orita K; Minoda Y; Sugama R; Ohta Y; Ueyama H; Takemura S; Nakamura H Bone Joint J; 2020 Nov; 102-B(11):1527-1534. PubMed ID: 33135435 [TBL] [Abstract][Full Text] [Related]
12. Biochemical analyses of human osteoarthritic and periprosthetic synovial fluid. Guenther LE; Pyle BW; Turgeon TR; Bohm ER; Wyss UP; Schmidt TA; Brandt JM Proc Inst Mech Eng H; 2014 Feb; 228(2):127-39. PubMed ID: 24429417 [TBL] [Abstract][Full Text] [Related]
13. How do gait frequency and serum-replacement interval affect polyethylene wear in knee-wear simulator tests? Reinders J; Sonntag R; Kretzer JP J Mater Sci Mater Med; 2014 Nov; 25(11):2463-9. PubMed ID: 25015325 [TBL] [Abstract][Full Text] [Related]
14. Sequentially annealed highly cross-linked polyethylene reduced in vivo wear particle generation in total knee arthroplasty. Minoda Y; Hata K; Goto K; Itohara T; Nakamura H J Orthop Surg (Hong Kong); 2017; 25(2):2309499017718909. PubMed ID: 28681671 [TBL] [Abstract][Full Text] [Related]
15. The influence of third-body particles on wear rate in unicondylar knee arthroplasty: a wear simulator study with bone and cement debris. Schroeder C; Grupp TM; Fritz B; Schilling C; Chevalier Y; Utzschneider S; Jansson V J Mater Sci Mater Med; 2013 May; 24(5):1319-25. PubMed ID: 23417520 [TBL] [Abstract][Full Text] [Related]
16. [Polyethylene particles in synovial fluid after knee arthroplasty with a conventional or highly cross-linked polyethylene. Preliminary study]. Hinarejos P; Torres A; Piñol I; Valverde D; Prats E; Puig L Rev Esp Cir Ortop Traumatol; 2012; 56(3):210-5. PubMed ID: 23594808 [TBL] [Abstract][Full Text] [Related]
17. Wear analysis of unicondylar mobile bearing and fixed bearing knee systems: a knee simulator study. Kretzer JP; Jakubowitz E; Reinders J; Lietz E; Moradi B; Hofmann K; Sonntag R Acta Biomater; 2011 Feb; 7(2):710-5. PubMed ID: 20883831 [TBL] [Abstract][Full Text] [Related]
18. Quantitative and qualitative analysis of polyethylene wear particles in synovial fluid of patients with total knee arthroplasty. A preliminary report. Bosco J; Benjamin J; Wallace D Clin Orthop Relat Res; 1994 Dec; (309):11-9. PubMed ID: 7994947 [TBL] [Abstract][Full Text] [Related]
19. Predicting knee replacement damage in a simulator machine using a computational model with a consistent wear factor. Zhao D; Sakoda H; Sawyer WG; Banks SA; Fregly BJ J Biomech Eng; 2008 Feb; 130(1):011004. PubMed ID: 18298180 [TBL] [Abstract][Full Text] [Related]
20. The influence of phospholipid concentration in protein-containing lubricants on the wear of ultra-high molecular weight polyethylene in artificial hip joints. Bell J; Tipper JL; Ingham E; Stone MH; Fisher J Proc Inst Mech Eng H; 2001; 215(2):259-63. PubMed ID: 11382086 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]