BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

277 related articles for article (PubMed ID: 25252695)

  • 1. Structural analysis of a stented pericardial heart valve with leaflets mounted externally.
    Avanzini A; Battini D
    Proc Inst Mech Eng H; 2014 Oct; 228(10):985-95. PubMed ID: 25252695
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Flat or curved pericardial aortic valve cusps: a finite element study.
    Lim KH; Candra J; Yeo JH; Duran CM
    J Heart Valve Dis; 2004 Sep; 13(5):792-7. PubMed ID: 15473482
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Functional analysis of bioprosthetic heart valves.
    Arcidiacono G; Corvi A; Severi T
    J Biomech; 2005 Jul; 38(7):1483-90. PubMed ID: 15922759
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Aortic valve leaflet mechanical properties facilitate diastolic valve function.
    Koch TM; Reddy BD; Zilla P; Franz T
    Comput Methods Biomech Biomed Engin; 2010; 13(2):225-34. PubMed ID: 19657802
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Numerical simulation of leaflet flexure in bioprosthetic valves mounted on rigid and expansile stents.
    Krucinski S; Vesely I; Dokainish MA; Campbell G
    J Biomech; 1993 Aug; 26(8):929-43. PubMed ID: 8349718
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Application of finite element analysis to the design of tissue leaflets for a percutaneous aortic valve.
    Smuts AN; Blaine DC; Scheffer C; Weich H; Doubell AF; Dellimore KH
    J Mech Behav Biomed Mater; 2011 Jan; 4(1):85-98. PubMed ID: 21094482
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Dynamic simulation pericardial bioprosthetic heart valve function.
    Kim H; Lu J; Sacks MS; Chandran KB
    J Biomech Eng; 2006 Oct; 128(5):717-24. PubMed ID: 16995758
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Computational fluid dynamics simulation of transcatheter aortic valve degeneration.
    Dwyer HA; Matthews PB; Azadani A; Jaussaud N; Ge L; Guy TS; Tseng EE
    Interact Cardiovasc Thorac Surg; 2009 Aug; 9(2):301-8. PubMed ID: 19414489
    [TBL] [Abstract][Full Text] [Related]  

  • 9. A coupled fluid-structure finite element model of the aortic valve and root.
    Nicosia MA; Cochran RP; Einstein DR; Rutland CJ; Kunzelman KS
    J Heart Valve Dis; 2003 Nov; 12(6):781-9. PubMed ID: 14658821
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Finite element investigation of stentless pericardial aortic valves: relevance of leaflet geometry.
    Xiong FL; Goetz WA; Chong CK; Chua YL; Pfeifer S; Wintermantel E; Yeo JH
    Ann Biomed Eng; 2010 May; 38(5):1908-18. PubMed ID: 20213213
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Analysis of the bending behaviour of porcine xenograft leaflets and of natural aortic valve material: bending stiffness, neutral axis and shear measurements.
    Vesely I; Boughner D
    J Biomech; 1989; 22(6-7):655-71. PubMed ID: 2509479
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Normal aortic valves stay open much longer in systole than porcine substitutes.
    Subhani M; Kumar RK; Balakrishnan KR
    Asian Cardiovasc Thorac Ann; 2013 Jun; 21(3):275-80. PubMed ID: 24570492
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Three-dimensional coupled fluid-structure simulation of pericardial bioprosthetic aortic valve function.
    Makhijani VB; Yang HQ; Dionne PJ; Thubrikar MJ
    ASAIO J; 1997; 43(5):M387-92. PubMed ID: 9360067
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Simulated bioprosthetic heart valve deformation under quasi-static loading.
    Sun W; Abad A; Sacks MS
    J Biomech Eng; 2005 Nov; 127(6):905-14. PubMed ID: 16438226
    [TBL] [Abstract][Full Text] [Related]  

  • 15. An optimal mounting frame to reduce flexural stresses of bioprosthetic heart valves.
    Vesely I; Krucinski S; Dokainish MA; Campbell G
    ASAIO J; 1994; 40(2):199-205. PubMed ID: 8003759
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Experimental validation of the fluid-structure interaction simulation of a bioprosthetic aortic heart valve.
    Kemp I; Dellimore K; Rodriguez R; Scheffer C; Blaine D; Weich H; Doubell A
    Australas Phys Eng Sci Med; 2013 Sep; 36(3):363-73. PubMed ID: 23907849
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Geometrical stress-reducing factors in the anisotropic porcine heart valves.
    Luo XY; Li WG; Li J
    J Biomech Eng; 2003 Oct; 125(5):735-44. PubMed ID: 14618934
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Stent and leaflet stresses in a 26-mm first-generation balloon-expandable transcatheter aortic valve.
    Xuan Y; Krishnan K; Ye J; Dvir D; Guccione JM; Ge L; Tseng EE
    J Thorac Cardiovasc Surg; 2017 May; 153(5):1065-1073. PubMed ID: 28108064
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Impact of Clinically Relevant Elliptical Deformations on the Damage Patterns of Sagging and Stretched Leaflets in a Bioprosthetic Heart Valve.
    Sritharan D; Fathi P; Weaver JD; Retta SM; Wu C; Duraiswamy N
    Cardiovasc Eng Technol; 2018 Sep; 9(3):351-364. PubMed ID: 29948838
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Computer modelling of bioprosthetic heart valves.
    Christie GW
    Eur J Cardiothorac Surg; 1992; 6 Suppl 1():S95-100; discussion S101. PubMed ID: 1389288
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 14.