BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

277 related articles for article (PubMed ID: 25252695)

  • 21. Fluid-Structure Interaction Study of Transcatheter Aortic Valve Dynamics Using Smoothed Particle Hydrodynamics.
    Mao W; Li K; Sun W
    Cardiovasc Eng Technol; 2016 Dec; 7(4):374-388. PubMed ID: 27844463
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Stress Analysis of Transcatheter Aortic Valve Leaflets Under Dynamic Loading: Effect of Reduced Tissue Thickness.
    Abbasi M; Azadani AN
    J Heart Valve Dis; 2017 Jul; 26(4):386-396. PubMed ID: 29302937
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Simulation of long-term fatigue damage in bioprosthetic heart valves: effects of leaflet and stent elastic properties.
    Martin C; Sun W
    Biomech Model Mechanobiol; 2014 Aug; 13(4):759-70. PubMed ID: 24092257
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Bioprosthetic heart valve leaflet deformation monitored by double-pulse stereo photogrammetry.
    Gao BZ; Pandya S; Arana C; Hwang NH
    Ann Biomed Eng; 2002 Jan; 30(1):11-8. PubMed ID: 11878276
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Anisotropic elasticity and strength of glutaraldehyde fixed bovine pericardium for use in pericardial bioprosthetic valves.
    Zioupos P; Barbenel JC; Fisher J
    J Biomed Mater Res; 1994 Jan; 28(1):49-57. PubMed ID: 8126028
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Natural preload of aortic valve leaflet components during glutaraldehyde fixation: effects on tissue mechanics.
    Vesely I; Lozon A
    J Biomech; 1993 Feb; 26(2):121-31. PubMed ID: 8429055
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Nanocomposite biomaterial mimicking aortic heart valve leaflet mechanical behaviour.
    Mohammadi H
    Proc Inst Mech Eng H; 2011 Jul; 225(7):718-22. PubMed ID: 21870379
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Simulated elliptical bioprosthetic valve deformation: implications for asymmetric transcatheter valve deployment.
    Sun W; Li K; Sirois E
    J Biomech; 2010 Dec; 43(16):3085-90. PubMed ID: 20817163
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Biomaterial optimization in a percutaneous aortic valve stent using finite element analysis.
    Kumar GV; Mathew L
    Cardiovasc Revasc Med; 2009; 10(4):247-51. PubMed ID: 19815172
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Prosthetic aortic heart valves: modeling and design.
    Mohammadi H; Mequanint K
    Med Eng Phys; 2011 Mar; 33(2):131-47. PubMed ID: 20971672
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Measurement and reconstruction of the leaflet geometry for a pericardial artificial heart valve.
    Jiang H; Campbell G; Xi F
    Med Eng Phys; 2005 Mar; 27(2):175-80. PubMed ID: 15642513
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Leaflet stress and strain distributions following incomplete transcatheter aortic valve expansion.
    Abbasi M; Azadani AN
    J Biomech; 2015 Oct; 48(13):3663-71. PubMed ID: 26338100
    [TBL] [Abstract][Full Text] [Related]  

  • 33. An experimentally derived stress resultant shell model for heart valve dynamic simulations.
    Kim H; Chandran KB; Sacks MS; Lu J
    Ann Biomed Eng; 2007 Jan; 35(1):30-44. PubMed ID: 17089074
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Effects of design parameters on the radial force of percutaneous aortic valve stents.
    Kumar GV; Mathew L
    Cardiovasc Revasc Med; 2010; 11(2):101-4. PubMed ID: 20347800
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Leaflet stress quantification of porcine vs bovine surgical bioprostheses: an
    Stanová V; Godio Raboutet Y; Barragan P; Thollon L; Pibarot P; Rieu R
    Comput Methods Biomech Biomed Engin; 2022 Jan; 25(1):40-51. PubMed ID: 34219548
    [TBL] [Abstract][Full Text] [Related]  

  • 36. A model of the geometrical changes in aortic valve leaflets in response to leaflet extension and variable boundary conditions.
    Fisher J; Butterfield M; Lockie KJ; Davies GA
    Proc Inst Mech Eng H; 1992; 206(1):7-14. PubMed ID: 1418197
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Structural analysis of the natural aortic valve in dynamics: from unpressurized to physiologically loaded.
    Labrosse MR; Lobo K; Beller CJ
    J Biomech; 2010 Jul; 43(10):1916-22. PubMed ID: 20378117
    [TBL] [Abstract][Full Text] [Related]  

  • 38. St Jude Epic heart valve bioprostheses versus native human and porcine aortic valves - comparison of mechanical properties.
    Kalejs M; Stradins P; Lacis R; Ozolanta I; Pavars J; Kasyanov V
    Interact Cardiovasc Thorac Surg; 2009 May; 8(5):553-6. PubMed ID: 19190025
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Influence of anisotropy on the mechanical behaviour of bioprosthetic heart valves.
    Burriesci G; Howard IC; Patterson EA
    J Med Eng Technol; 1999; 23(6):203-15. PubMed ID: 10738683
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Remodelling of material structure in aortic valve leaflet.
    Patralski K; Konderla P
    Acta Bioeng Biomech; 2015; 17(2):63-72. PubMed ID: 26399228
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 14.