265 related articles for article (PubMed ID: 25255665)
1. [McGRATH MAC Videolaryngoscope: clinical assessment of its performance in 50 surgical patients].
Negishi Y; Shimada N; Urayama M; Niwa Y; Takeuchi M
Masui; 2014 Sep; 63(9):1025-8. PubMed ID: 25255665
[TBL] [Abstract][Full Text] [Related]
2. [The C-MAC videolaryngoscope: its utility in tracheal intubation by novice personnel].
Shimada N; Mogi K; Niwa Y; Hayashi K; Negishi Y; Kaneko A; Takeuchi M
Masui; 2012 Jun; 61(6):649-52. PubMed ID: 22746034
[TBL] [Abstract][Full Text] [Related]
3. [Video-laryngoscope (McGRATH MAC): a clinical assessment of its performance in consecutive 100 patients].
Arai T; Suzuki H; Ogawa K; Saito T; Hashimoto Y; Shimazaki M; Asai T; Okuda Y
Masui; 2014 Apr; 63(4):468-71. PubMed ID: 24783620
[TBL] [Abstract][Full Text] [Related]
4. Randomized controlled trial comparing the McGrath videolaryngoscope with the C-MAC videolaryngoscope in intubating adult patients with potential difficult airways.
Ng I; Hill AL; Williams DL; Lee K; Segal R
Br J Anaesth; 2012 Sep; 109(3):439-43. PubMed ID: 22677878
[TBL] [Abstract][Full Text] [Related]
5. [The KINGVISION: clinical assessment of performance in 50 patients].
Shimada N; Hayashi K; Sugimoto K; Takahashi M; Niwa Y; Takeuchi M
Masui; 2013 Jun; 62(6):757-60. PubMed ID: 23815009
[TBL] [Abstract][Full Text] [Related]
6. Comparative efficacy of C-MAC
Gupta A; Singh P; Gupta N; Kumar Malhotra R; Girdhar KK
Paediatr Anaesth; 2021 Oct; 31(10):1089-1096. PubMed ID: 34153141
[TBL] [Abstract][Full Text] [Related]
7. A comparison of the McGrath® Series 5 videolaryngoscope and Macintosh laryngoscope for double-lumen tracheal tube placement in patients with a good glottic view at direct laryngoscopy.
Yao WL; Wan L; Xu H; Qian W; Wang XR; Tian YK; Zhang CH
Anaesthesia; 2015 Jul; 70(7):810-7. PubMed ID: 25721326
[TBL] [Abstract][Full Text] [Related]
8. Tracheal intubation with a flexible fibreoptic scope or the McGrath videolaryngoscope in simulated difficult airway scenarios: a randomised controlled manikin study.
Jepsen CH; Gätke MR; Thøgersen B; Mollerup LT; Ruhnau B; Rewers M; Rosenstock CV
Eur J Anaesthesiol; 2014 Mar; 31(3):131-6. PubMed ID: 24145800
[TBL] [Abstract][Full Text] [Related]
9. [Usefulness of the McGRATH® Videolaryngoscope in 100 Children].
Endo S; Saito T; Hashimoto Y; Arai T; Asai T; Okuda Y
Masui; 2015 Oct; 64(10):1097-100. PubMed ID: 26742419
[TBL] [Abstract][Full Text] [Related]
10. A comparison of the ease of tracheal intubation using a McGrath MAC(®) laryngoscope and a standard Macintosh laryngoscope.
Wallace CD; Foulds LT; McLeod GA; Younger RA; McGuire BE
Anaesthesia; 2015 Nov; 70(11):1281-5. PubMed ID: 26336853
[TBL] [Abstract][Full Text] [Related]
11. Comparing the first-attempt tracheal intubation success of the hyperangulated McGrath® X-blade vs the Macintosh-type CMAC videolaryngoscope in patients with cervical immobilization: a two-centre randomized controlled trial.
Zhang J; Tan LZ; Toh H; Foo CW; Wijeratne S; Hu H; Seet E
J Clin Monit Comput; 2022 Aug; 36(4):1139-1145. PubMed ID: 34347225
[TBL] [Abstract][Full Text] [Related]
12. Evaluation of the McGrath Series 5 videolaryngoscope after failed direct laryngoscopy.
Noppens RR; Möbus S; Heid F; Schmidtmann I; Werner C; Piepho T
Anaesthesia; 2010 Jul; 65(7):716-20. PubMed ID: 20528841
[TBL] [Abstract][Full Text] [Related]
13. The McGrath® Series 5 videolaryngoscope vs the Macintosh laryngoscope: a randomised, controlled trial in patients with a simulated difficult airway.
Taylor AM; Peck M; Launcelott S; Hung OR; Law JA; MacQuarrie K; McKeen D; George RB; Ngan J
Anaesthesia; 2013 Feb; 68(2):142-7. PubMed ID: 23121470
[TBL] [Abstract][Full Text] [Related]
14. McGrath MAC Videolaryngoscope Versus Optiscope Video Stylet for Tracheal Intubation in Patients With Manual Inline Cervical Stabilization: A Randomized Trial.
Yoon HK; Lee HC; Park JB; Oh H; Park HP
Anesth Analg; 2020 Apr; 130(4):870-878. PubMed ID: 31567321
[TBL] [Abstract][Full Text] [Related]
15. Comparison of the Pentax AirwayScope and McGrath MAC videolaryngoscope for endotracheal intubation in patients with a normal airway.
Lee J; Kwak HJ; Lee JY; Chang MY; Lee SY; Kim JY
Medicine (Baltimore); 2017 Nov; 96(46):e8713. PubMed ID: 29145308
[TBL] [Abstract][Full Text] [Related]
16. A Macintosh laryngoscope blade for videolaryngoscopy reduces stylet use in patients with normal airways.
van Zundert A; Maassen R; Lee R; Willems R; Timmerman M; Siemonsma M; Buise M; Wiepking M
Anesth Analg; 2009 Sep; 109(3):825-31. PubMed ID: 19690253
[TBL] [Abstract][Full Text] [Related]
17. Tracheal intubation with the McGrath MAC X-blade videolaryngoscope in morbidly obese and nonobese patients.
Arslan Zİ; Yörükoğlu HU
Turk J Med Sci; 2019 Oct; 49(5):1540-1546. PubMed ID: 31652034
[TBL] [Abstract][Full Text] [Related]
18. Postoperative sore throat and subglottic injury after McGrath® MAC videolaryngoscopic intubation with versus without a stylet in patients with a high Mallampati score: a randomized controlled trial.
Yoon HK; Lee HC; Oh H; Jun K; Park HP
BMC Anesthesiol; 2019 Jul; 19(1):137. PubMed ID: 31366325
[TBL] [Abstract][Full Text] [Related]
19. [Use of a New Video-laryngoscope (McGRATH® X-blade™) in Patients with Difficult Airways].
Arai T; Yamamoto Y; Kikuchi A; Okuda Y
Masui; 2015 Oct; 64(10):1048-51. PubMed ID: 26742406
[TBL] [Abstract][Full Text] [Related]
20. Randomized controlled trial of intubation with the McGrath Series 5 videolaryngoscope by inexperienced anaesthetists.
Walker L; Brampton W; Halai M; Hoy C; Lee E; Scott I; McLernon DJ
Br J Anaesth; 2009 Sep; 103(3):440-5. PubMed ID: 19605408
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]