These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

268 related articles for article (PubMed ID: 25259939)

  • 1. Inpatient trial of an artificial pancreas based on multiple model probabilistic predictive control with repeated large unannounced meals.
    Cameron F; Niemeyer G; Wilson DM; Bequette BW; Benassi KS; Clinton P; Buckingham BA
    Diabetes Technol Ther; 2014 Nov; 16(11):728-34. PubMed ID: 25259939
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Fully Closed-Loop Multiple Model Probabilistic Predictive Controller Artificial Pancreas Performance in Adolescents and Adults in a Supervised Hotel Setting.
    Forlenza GP; Cameron FM; Ly TT; Lam D; Howsmon DP; Baysal N; Kulina G; Messer L; Clinton P; Levister C; Patek SD; Levy CJ; Wadwa RP; Maahs DM; Bequette BW; Buckingham BA
    Diabetes Technol Ther; 2018 May; 20(5):335-343. PubMed ID: 29658779
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Multicenter closed-loop insulin delivery study points to challenges for keeping blood glucose in a safe range by a control algorithm in adults and adolescents with type 1 diabetes from various sites.
    Zisser H; Renard E; Kovatchev B; Cobelli C; Avogaro A; Nimri R; Magni L; Buckingham BA; Chase HP; Doyle FJ; Lum J; Calhoun P; Kollman C; Dassau E; Farret A; Place J; Breton M; Anderson SM; Dalla Man C; Del Favero S; Bruttomesso D; Filippi A; Scotton R; Phillip M; Atlas E; Muller I; Miller S; Toffanin C; Raimondo DM; De Nicolao G; Beck RW;
    Diabetes Technol Ther; 2014 Oct; 16(10):613-22. PubMed ID: 25003311
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Closed-Loop Control Without Meal Announcement in Type 1 Diabetes.
    Cameron FM; Ly TT; Buckingham BA; Maahs DM; Forlenza GP; Levy CJ; Lam D; Clinton P; Messer LH; Westfall E; Levister C; Xie YY; Baysal N; Howsmon D; Patek SD; Bequette BW
    Diabetes Technol Ther; 2017 Sep; 19(9):527-532. PubMed ID: 28767276
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Multivariable adaptive closed-loop control of an artificial pancreas without meal and activity announcement.
    Turksoy K; Bayrak ES; Quinn L; Littlejohn E; Cinar A
    Diabetes Technol Ther; 2013 May; 15(5):386-400. PubMed ID: 23544672
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Clinical evaluation of an automated artificial pancreas using zone-model predictive control and health monitoring system.
    Harvey RA; Dassau E; Bevier WC; Seborg DE; Jovanovič L; Doyle FJ; Zisser HC
    Diabetes Technol Ther; 2014 Jun; 16(6):348-57. PubMed ID: 24471561
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Closed-loop artificial pancreas using subcutaneous glucose sensing and insulin delivery and a model predictive control algorithm: the Virginia experience.
    Clarke WL; Anderson S; Breton M; Patek S; Kashmer L; Kovatchev B
    J Diabetes Sci Technol; 2009 Sep; 3(5):1031-8. PubMed ID: 20144416
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Closed-loop artificial pancreas using subcutaneous glucose sensing and insulin delivery and a model predictive control algorithm: preliminary studies in Padova and Montpellier.
    Bruttomesso D; Farret A; Costa S; Marescotti MC; Vettore M; Avogaro A; Tiengo A; Dalla Man C; Place J; Facchinetti A; Guerra S; Magni L; De Nicolao G; Cobelli C; Renard E; Maran A
    J Diabetes Sci Technol; 2009 Sep; 3(5):1014-21. PubMed ID: 20144414
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Zone model predictive control: a strategy to minimize hyper- and hypoglycemic events.
    Grosman B; Dassau E; Zisser HC; Jovanovic L; Doyle FJ
    J Diabetes Sci Technol; 2010 Jul; 4(4):961-75. PubMed ID: 20663463
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Overnight closed-loop insulin delivery with model predictive control: assessment of hypoglycemia and hyperglycemia risk using simulation studies.
    Wilinska ME; Budiman ES; Taub MB; Elleri D; Allen JM; Acerini CL; Dunger DB; Hovorka R
    J Diabetes Sci Technol; 2009 Sep; 3(5):1109-20. PubMed ID: 20144424
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Artificial Pancreas: Evaluating the ARG Algorithm Without Meal Announcement.
    Fushimi E; Colmegna P; De Battista H; Garelli F; Sánchez-Peña R
    J Diabetes Sci Technol; 2019 Nov; 13(6):1035-1043. PubMed ID: 31339059
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Unannounced Meal Challenges Using an Advanced Hybrid Closed-Loop System.
    Shalit R; Minsky N; Laron-Hirsh M; Cohen O; Kurtz N; Roy A; Grosman B; Benedetti A; Tirosh A
    Diabetes Technol Ther; 2023 Sep; 25(9):579-588. PubMed ID: 37335759
    [No Abstract]   [Full Text] [Related]  

  • 13. Automatic Detection and Estimation of Unannounced Meals for Multivariable Artificial Pancreas System.
    Samadi S; Rashid M; Turksoy K; Feng J; Hajizadeh I; Hobbs N; Lazaro C; Sevil M; Littlejohn E; Cinar A
    Diabetes Technol Ther; 2018 Mar; 20(3):235-246. PubMed ID: 29406789
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Stress Testing of an Artificial Pancreas System With Pizza and Exercise Leads to Improvements in the System's Fuzzy Logic Controller.
    Mauseth R; Lord SM; Hirsch IB; Kircher RC; Matheson DP; Greenbaum CJ
    J Diabetes Sci Technol; 2015 Sep; 9(6):1253-9. PubMed ID: 26370244
    [TBL] [Abstract][Full Text] [Related]  

  • 15. The Efficacy of Basal Rate and Carbohydrate Ratio Learning Algorithm for Closed-Loop Insulin Delivery (Artificial Pancreas) in Youth with Type 1 Diabetes in a Diabetes Camp.
    Palisaitis E; El Fathi A; Von Oettingen JE; Krishnamoorthy P; Kearney R; Jacobs P; Rutkowski J; Legault L; Haidar A
    Diabetes Technol Ther; 2020 Mar; 22(3):185-194. PubMed ID: 31596127
    [No Abstract]   [Full Text] [Related]  

  • 16. Probabilistic evolving meal detection and estimation of meal total glucose appearance.
    Cameron F; Niemeyer G; Buckingham BA
    J Diabetes Sci Technol; 2009 Sep; 3(5):1022-30. PubMed ID: 20144415
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Safety and Feasibility of the OmniPod Hybrid Closed-Loop System in Adult, Adolescent, and Pediatric Patients with Type 1 Diabetes Using a Personalized Model Predictive Control Algorithm.
    Buckingham BA; Forlenza GP; Pinsker JE; Christiansen MP; Wadwa RP; Schneider J; Peyser TA; Dassau E; Lee JB; O'Connor J; Layne JE; Ly TT
    Diabetes Technol Ther; 2018 Apr; 20(4):257-262. PubMed ID: 29431513
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Artificial pancreas using a personalized rule-based controller achieves overnight normoglycemia in patients with type 1 diabetes.
    Capel I; Rigla M; García-Sáez G; Rodríguez-Herrero A; Pons B; Subías D; García-García F; Gallach M; Aguilar M; Pérez-Gandía C; Gómez EJ; Caixàs A; Hernando ME
    Diabetes Technol Ther; 2014 Mar; 16(3):172-9. PubMed ID: 24152323
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Internal model control based module for the elimination of meal and exercise announcements in hybrid artificial pancreas systems.
    Sala-Mira I; Garcia P; Díez JL; Bondia J
    Comput Methods Programs Biomed; 2022 Nov; 226():107061. PubMed ID: 36116400
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Intraperitoneal insulin delivery provides superior glycaemic regulation to subcutaneous insulin delivery in model predictive control-based fully-automated artificial pancreas in patients with type 1 diabetes: a pilot study.
    Dassau E; Renard E; Place J; Farret A; Pelletier MJ; Lee J; Huyett LM; Chakrabarty A; Doyle FJ; Zisser HC
    Diabetes Obes Metab; 2017 Dec; 19(12):1698-1705. PubMed ID: 28474383
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 14.