These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
382 related articles for article (PubMed ID: 25261913)
1. Clinical investigation for displaced proximal humeral fractures in the elderly: a randomized study of two surgical treatments: reverse total prosthetic replacement versus angular stable plate Philos (The DELPHI-trial). Fjalestad T; Iversen P; Hole MØ; Smedsrud M; Madsen JE BMC Musculoskelet Disord; 2014 Sep; 15():323. PubMed ID: 25261913 [TBL] [Abstract][Full Text] [Related]
2. Reverse Shoulder Arthroplasty Is Superior to Plate Fixation at 2 Years for Displaced Proximal Humeral Fractures in the Elderly: A Multicenter Randomized Controlled Trial. Fraser AN; Bjørdal J; Wagle TM; Karlberg AC; Lien OA; Eilertsen L; Mader K; Apold H; Larsen LB; Madsen JE; Fjalestad T J Bone Joint Surg Am; 2020 Mar; 102(6):477-485. PubMed ID: 31977825 [TBL] [Abstract][Full Text] [Related]
3. Reverse total shoulder versus angular stable plate treatment for proximal humeral fractures in over 65 years old patients. Giardella A; Ascione F; Mocchi M; Berlusconi M; Romano AM; Oliva F; Maradei L Muscles Ligaments Tendons J; 2017; 7(2):271-278. PubMed ID: 29264338 [TBL] [Abstract][Full Text] [Related]
4. Surgical treatment with an angular stable plate for complex displaced proximal humeral fractures in elderly patients: a randomized controlled trial. Fjalestad T; Hole MØ; Hovden IA; Blücher J; Strømsøe K J Orthop Trauma; 2012 Feb; 26(2):98-106. PubMed ID: 21804410 [TBL] [Abstract][Full Text] [Related]
5. Locking nail versus locking plate for proximal humeral fracture fixation in an elderly population: a prospective randomised controlled trial. Plath JE; Kerschbaum C; Seebauer T; Holz R; Henderson DJH; Förch S; Mayr E BMC Musculoskelet Disord; 2019 Jan; 20(1):20. PubMed ID: 30630465 [TBL] [Abstract][Full Text] [Related]
6. Surgical treatment of Neer Group VI proximal humeral fractures: retrospective comparison of PHILOS® and hemiarthroplasty. Spross C; Platz A; Erschbamer M; Lattmann T; Dietrich M Clin Orthop Relat Res; 2012 Jul; 470(7):2035-42. PubMed ID: 22161081 [TBL] [Abstract][Full Text] [Related]
7. Which parameters affect medium- to long-term results after angular stable plate fixation for proximal humeral fractures? Bahrs C; Kühle L; Blumenstock G; Stöckle U; Rolauffs B; Freude T J Shoulder Elbow Surg; 2015 May; 24(5):727-32. PubMed ID: 25441560 [TBL] [Abstract][Full Text] [Related]
8. Pegs not superior to screws for fixation of fractures of the proximal humerus. Bønes I; Karlberg AC; Liljeholm M; Fraser AN; Madsen JE; Fjalestad T J Orthop Surg Res; 2022 Feb; 17(1):66. PubMed ID: 35109905 [TBL] [Abstract][Full Text] [Related]
9. Functional outcome and complications following PHILOS plate fixation in proximal humeral fractures. Geiger EV; Maier M; Kelm A; Wutzler S; Seebach C; Marzi I Acta Orthop Traumatol Turc; 2010; 44(1):1-6. PubMed ID: 20513984 [TBL] [Abstract][Full Text] [Related]
10. Functional results of angular-stable plate fixation in displaced proximal humeral fractures. Handschin AE; Cardell M; Contaldo C; Trentz O; Wanner GA Injury; 2008 Mar; 39(3):306-13. PubMed ID: 18243202 [TBL] [Abstract][Full Text] [Related]
11. External validity in a multicenter randomized clinical trial of proximal humeral fractures: the DelPhi trial. Tallay E; Lindberg SK; Lee-Ødegård S; Bjordal J; Fraser AN; Madsen JE; Fjalestad T Eur J Orthop Surg Traumatol; 2022 Feb; 32(2):317-323. PubMed ID: 33880653 [TBL] [Abstract][Full Text] [Related]
12. Open reduction and internal fixation of proximal humeral fractures with use of the locking proximal humerus plate. Results of a prospective, multicenter, observational study. Südkamp N; Bayer J; Hepp P; Voigt C; Oestern H; Kääb M; Luo C; Plecko M; Wendt K; Köstler W; Konrad G J Bone Joint Surg Am; 2009 Jun; 91(6):1320-8. PubMed ID: 19487508 [TBL] [Abstract][Full Text] [Related]
19. Fractures and fracture-dislocations of the proximal humerus: A retrospective analysis of 82 cases treated with the Philos(®) locking plate. Erasmo R; Guerra G; Guerra L Injury; 2014 Dec; 45 Suppl 6():S43-8. PubMed ID: 25457318 [TBL] [Abstract][Full Text] [Related]
20. Nordic Innovative Trials to Evaluate osteoPorotic Fractures (NITEP) Collaboration: The Nordic DeltaCon Trial protocol-non-operative treatment versus reversed total shoulder arthroplasty in patients 65 years of age and older with a displaced proximal humerus fracture: a prospective, randomised controlled trial. Launonen AP; Fjalestad T; Laitinen MK; Lähdeoja T; Ekholm C; Wagle T; Mattila VM; BMJ Open; 2019 Jan; 9(1):e024916. PubMed ID: 30700485 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]