1. Evaluation of the minimum volume of salvage blood required for the successful use of two different autotransfusion devices. Baumann C; Lamesic G; Weiss M; Cushing MM; Haas T Paediatr Anaesth; 2015 Mar; 25(3):258-64. PubMed ID: 25267461 [TBL] [Abstract][Full Text] [Related]
2. Processing of small volumes in blood salvage devices. Seyfried T; Breu A; Gruber M; Reipert J; Hansen E Transfusion; 2014 Oct; 54(10 Pt 2):2775-81. PubMed ID: 24953124 [TBL] [Abstract][Full Text] [Related]
3. Comparison of three autotransfusion devices for utilization in the pediatric population. Melchior RW; Dreher M; Shade B; Chappell A; Fisher D; Rosenthal T Perfusion; 2021 Jan; 36(1):57-62. PubMed ID: 32475210 [TBL] [Abstract][Full Text] [Related]
4. Washing of banked blood by three different blood salvage devices. Gruber M; Breu A; Frauendorf M; Seyfried T; Hansen E Transfusion; 2013 May; 53(5):1001-9. PubMed ID: 22897672 [TBL] [Abstract][Full Text] [Related]
5. [Post-operative retransfusion and intra-operative autotransfusion systems in total knee arthroplasty. A comparison of their efficacy]. Kučera B; Náhlík D; Hart R; Oceláková L Acta Chir Orthop Traumatol Cech; 2012; 79(4):361-6. PubMed ID: 22980936 [TBL] [Abstract][Full Text] [Related]
6. The volume of returned red blood cells in a large blood salvage program: where does it all go? Waters JH; Dyga RM; Waters JF; Yazer MH Transfusion; 2011 Oct; 51(10):2126-32. PubMed ID: 21985047 [TBL] [Abstract][Full Text] [Related]
7. Fat removal during cell salvage: an optimized program for a discontinuous autotransfusion device. Seyfried TF; Gruber M; Breu A; Aumeier C; Zech N; Hansen E Transfusion; 2016 Jan; 56(1):153-9. PubMed ID: 26331951 [TBL] [Abstract][Full Text] [Related]
8. The impact of bowl size, program setup, and blood hematocrit on the performance of a discontinuous autotransfusion system. Seyfried TF; Gruber M; Streithoff F; Mandle RJ; Pawlik MT; Busse H; Hansen E Transfusion; 2017 Mar; 57(3):589-598. PubMed ID: 28233319 [TBL] [Abstract][Full Text] [Related]
9. Quality evaluation of the emergency program of three contemporary cell-washing machines. De Somer F; Bernolet H; Bouchez S; Bové T Perfusion; 2019 May; 34(4):318-322. PubMed ID: 30628532 [TBL] [Abstract][Full Text] [Related]
10. [Mechanical autologous transfusion in orthopedic surgery in children. Is the use of mechanical autologous transfusion possible even in pediatric orthopedic surgical procedures?]. Michaelis G; Melzer C; Biscoping J; Hempelmann G Anaesthesist; 1995 Jul; 44(7):501-7. PubMed ID: 7661337 [TBL] [Abstract][Full Text] [Related]
11. In Vitro Evaluation of the Fresenius Kabi CATSmart Autotransfusion System. Alberts M; Groom RC; Walczak R; Kramer R; Karpiel A; Dieter J; Sheth L; Greene NH; Jooste EH J Extra Corpor Technol; 2017 Jun; 49(2):107-111. PubMed ID: 28638159 [TBL] [Abstract][Full Text] [Related]
12. Quality assessment of intraoperative blood salvage and autotransfusion. Spain DA; Miller FB; Bergamini TM; Montgomery RC; Richardson JD Am Surg; 1997 Dec; 63(12):1059-63; discussion 1063-4. PubMed ID: 9393253 [TBL] [Abstract][Full Text] [Related]
13. Fat elimination during intraoperative autotransfusion: an in vitro investigation. Booke M; Fobker M; Fingerhut D; Storm M; Mortlemans Y; Van Aken H Anesth Analg; 1997 Nov; 85(5):959-62. PubMed ID: 9356084 [TBL] [Abstract][Full Text] [Related]
14. Quick biochemical markers for assessment of quality control of intraoperative cell salvage: a prospective observational study. Dong P; Che J; Li X; Tian M; Smith FG J Cardiothorac Surg; 2014 May; 9():86. PubMed ID: 24886505 [TBL] [Abstract][Full Text] [Related]
15. [Autotransfusion of cord blood erythrocytes in newborns with malformations requiring early surgical intervention]. Titkov KV Anesteziol Reanimatol; 2014; 59(6):38-43. PubMed ID: 25831701 [TBL] [Abstract][Full Text] [Related]
16. The Influence of Intraoperative Autotransfusion on Postoperative Hematocrit after Cardiac Surgery: A Cross-Sectional Study. Stasko AJ; Stammers AH; Mongero LB; Tesdahl EA; Weinstein S J Extra Corpor Technol; 2017 Dec; 49(4):241-248. PubMed ID: 29302114 [TBL] [Abstract][Full Text] [Related]
17. Reinfusate Heparin Concentrations Produced by Two Autotransfusion Systems. Buys WF; Buys M; Levin AI J Cardiothorac Vasc Anesth; 2017 Feb; 31(1):90-98. PubMed ID: 27591910 [TBL] [Abstract][Full Text] [Related]
18. Patient blood management in elective total hip- and knee-replacement surgery (part 2): a randomized controlled trial on blood salvage as transfusion alternative using a restrictive transfusion policy in patients with a preoperative hemoglobin above 13 g/dl. So-Osman C; Nelissen RG; Koopman-van Gemert AW; Kluyver E; Pöll RG; Onstenk R; Van Hilten JA; Jansen-Werkhoven TM; van den Hout WB; Brand R; Brand A Anesthesiology; 2014 Apr; 120(4):852-60. PubMed ID: 24434302 [TBL] [Abstract][Full Text] [Related]
19. Quality of red blood cells using autotransfusion devices: a comparative analysis. Serrick CJ; Scholz M; Melo A; Singh O; Noel D J Extra Corpor Technol; 2003 Mar; 35(1):28-34. PubMed ID: 12680493 [TBL] [Abstract][Full Text] [Related]
20. How do I perform cell salvage in obstetrics? Waters JH; Beck S; Yazer MH Transfusion; 2019 Jul; 59(7):2199-2202. PubMed ID: 31145473 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]