302 related articles for article (PubMed ID: 25269654)
1. Biomechanical comparison of Krackow locking stitch versus nonlocking loop stitch with varying number of throws.
Hahn JM; Inceoğlu S; Wongworawat MD
Am J Sports Med; 2014 Dec; 42(12):3003-8. PubMed ID: 25269654
[TBL] [Abstract][Full Text] [Related]
2. Biomechanical properties of porcine flexor tendon fixation with varying throws and stitch methods.
Sakaguchi K; Tachibana Y; Oda H
Am J Sports Med; 2012 Jul; 40(7):1641-5. PubMed ID: 22691458
[TBL] [Abstract][Full Text] [Related]
3. Krackow locking stitch versus nonlocking premanufactured loop stitch for soft-tissue fixation: a biomechanical study.
Deramo DM; White KL; Parks BG; Hinton RY
Arthroscopy; 2008 May; 24(5):599-603. PubMed ID: 18442694
[TBL] [Abstract][Full Text] [Related]
4. Effect of the number of suture throws on the biomechanical characteristics of the suture-tendon construct.
Hong CK; Lin CL; Chang CH; Jou IM; Su WR
Arthroscopy; 2014 Dec; 30(12):1609-15. PubMed ID: 25174535
[TBL] [Abstract][Full Text] [Related]
5. The modified finger-trap suture technique: a biomechanical comparison of a novel suture technique for graft fixation.
Su WR; Chu CH; Lin CL; Lin CJ; Jou IM; Chang CW
Arthroscopy; 2012 May; 28(5):702-10. PubMed ID: 22261138
[TBL] [Abstract][Full Text] [Related]
6. Soft Tissue Fixation Strategies of Human Quadriceps Tendon Grafts: A Biomechanical Study.
Michel PA; Domnick C; Raschke MJ; Kittl C; Glasbrenner J; Deitermann L; Fink C; Herbort M
Arthroscopy; 2019 Nov; 35(11):3069-3076. PubMed ID: 31405619
[TBL] [Abstract][Full Text] [Related]
7. Core weave versus Krackow technique for Achilles tendon repair: a biomechanical study.
Hong Y; Hermida L; White KL; Parks BG; Camire LM; Guyton C
Foot Ankle Int; 2010 Dec; 31(12):1107-10. PubMed ID: 21189213
[TBL] [Abstract][Full Text] [Related]
8. Biomechanical Comparison of a Novel Multiplanar, Perpendicular Whipstitch With the Krackow Stitch and Standard Commercial Whipstitch.
Muscatelli S; Walley KC; Daly-Seiler CS; Greenstein JA; Sciascia A; Patterson DP; Freehill MT
Orthop J Sports Med; 2022 Aug; 10(8):23259671221107034. PubMed ID: 35982831
[TBL] [Abstract][Full Text] [Related]
9. Superior biomechanical properties and tying time with the modified Prusik knot and Wittstein suture loop to the Krackow stitch.
Hong CK; Lin CL; Yang JM; Shih CA; Chou YC; Yeh ML; Chiang CH; Su WR
Arch Orthop Trauma Surg; 2018 Feb; 138(2):237-244. PubMed ID: 29075842
[TBL] [Abstract][Full Text] [Related]
10. Krackow Stitch and Whipstitch Use in Distal Biceps Tendon Rupture Repair: A Porcine Composite Bone Biomechanical Study.
DiVella M; Cecora A; Duell B; Fogel J; Ruotolo C
Orthopedics; 2023; 46(4):224-229. PubMed ID: 36779732
[TBL] [Abstract][Full Text] [Related]
11. The Krackow stitch: a biomechanical evaluation of changing the number of loops versus the number of sutures.
McKeon BP; Heming JF; Fulkerson J; Langeland R
Arthroscopy; 2006 Jan; 22(1):33-7. PubMed ID: 16399458
[TBL] [Abstract][Full Text] [Related]
12. Do Needleless Knots have Similar Strength as the Krackow Suture? An In Vitro Porcine Tendon Study.
Hong CK; Kuo TH; Yeh ML; Jou IM; Lin CL; Su WR
Clin Orthop Relat Res; 2017 Feb; 475(2):552-557. PubMed ID: 27822894
[TBL] [Abstract][Full Text] [Related]
13. A Biomechanical Evaluation of Various Double Krackow Suture Techniques for Soft-Tissue Graft Fixation.
Hong CK; Lin CL; Kuan FC; Wang PH; Yeh ML; Su WR
Arthroscopy; 2018 Mar; 34(3):663-668. PubMed ID: 29229418
[TBL] [Abstract][Full Text] [Related]
14. Biomechanical Characterization of a New Locking Loop Stitch for Graft Fixation versus Krackow Stitch.
Itami Y; Limpisvasti O; McGarry MH; Patel NA; Lin CC; Dooney T; Mihata T; Neo M; Lee TQ
Clin Orthop Surg; 2023 Jun; 15(3):508-515. PubMed ID: 37274497
[TBL] [Abstract][Full Text] [Related]
15. Longer stitch interval in the Krackow stitch for tendon graft fixation leads to poorer biomechanical property.
Hong CK; Lin CL; Kuan FC; Wang PH; Yeh ML; Su WR
J Orthop Surg (Hong Kong); 2018; 26(3):2309499018799514. PubMed ID: 30235966
[TBL] [Abstract][Full Text] [Related]
16. A Biomechanical Comparison of High-Tensile Strength Tape Versus High-Tensile Strength Suture for Tendon Fixation Under Cyclic Loading.
Le AH; Roach WB; Mauntel TC; Hendershot BD; Helgeson MD; Colantonio DF; Fredericks DR; Slaven SE; Pisano AJ; LeClere LE
Arthroscopy; 2021 Sep; 37(9):2925-2933. PubMed ID: 33901508
[TBL] [Abstract][Full Text] [Related]
17. Biomechanical characteristics of a new looping stitch versus the classic Krackow stitch for distal biceps fixation.
Long C; Nakla A; Chung MS; Kwak D; McGarry MH; Hauck O; Limpisvasti O; Adamson GJ; Lee TQ
JSES Int; 2023 Jul; 7(4):685-691. PubMed ID: 37426934
[TBL] [Abstract][Full Text] [Related]
18. A Biomechanical Comparison of Modified Krackow and Locking Loop Suture Patterns for Soft-Tissue Graft Fixation.
Ostrander RV; Saper MG; Juelson TJ
Arthroscopy; 2016 Jul; 32(7):1384-8. PubMed ID: 27085852
[TBL] [Abstract][Full Text] [Related]
19. Strength of different Krackow stitch configurations using high-strength suture.
Hapa O; Erduran M; Havitçioğlu H; Çeçen B; Akşahin E; Güler S; Atalay K
J Foot Ankle Surg; 2013; 52(4):448-50. PubMed ID: 23611415
[TBL] [Abstract][Full Text] [Related]
20. Biomechanical Head-to-Head Comparison of 2 Sutures and the Giftbox Versus Bunnell Techniques for Midsubstance Achilles Tendon Ruptures.
Van Dyke RO; Chaudhary SA; Gould G; Trimba R; Laughlin RT
Orthop J Sports Med; 2017 May; 5(5):2325967117707477. PubMed ID: 28607938
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]