832 related articles for article (PubMed ID: 25271991)
21. Comparison of the Tono-Pen and Goldmann tonometer for measuring intraocular pressure in patients with glaucoma.
Horowitz GS; Byles J; Lee J; D'Este C
Clin Exp Ophthalmol; 2004 Dec; 32(6):584-9. PubMed ID: 15575828
[TBL] [Abstract][Full Text] [Related]
22. Measurement of the difference in intraocular pressure between the sitting and lying body positions in healthy subjects: direct comparison of the Icare Pro with the Goldmann applanation tonometer, Pneumatonometer and Tonopen XL.
Barkana Y; Gutfreund S
Clin Exp Ophthalmol; 2014; 42(7):608-14. PubMed ID: 24299102
[TBL] [Abstract][Full Text] [Related]
23. Comparison of intraocular pressure measurement between rebound, non-contact and Goldmann applanation tonometry in treated glaucoma patients.
Vincent SJ; Vincent RA; Shields D; Lee GA
Clin Exp Ophthalmol; 2012; 40(4):e163-70. PubMed ID: 21883774
[TBL] [Abstract][Full Text] [Related]
24. Precision and accuracy of the ICare tonometer - Peripheral and central IOP measurements by rebound tonometry.
Muttuvelu DV; Baggesen K; Ehlers N
Acta Ophthalmol; 2012 Jun; 90(4):322-6. PubMed ID: 20840218
[TBL] [Abstract][Full Text] [Related]
25. Effect of cataract surgery on intraocular pressure in supine and lateral decubitus body postures.
Park JH; Yoo C; Song JS; Lin SC; Kim YY
Indian J Ophthalmol; 2016 Oct; 64(10):727-732. PubMed ID: 27905333
[TBL] [Abstract][Full Text] [Related]
26. Is the tono-pen accurate for measuring intraocular pressure in young children with congenital glaucoma?
Levy J; Lifshitz T; Rosen S; Tessler Z; Biedner BZ
J AAPOS; 2005 Aug; 9(4):321-5. PubMed ID: 16102480
[TBL] [Abstract][Full Text] [Related]
27. Postural change in intraocular pressure: a comparison of measurement with a Goldmann tonometer, Tonopen XL, pneumatonometer, and HA-2.
Barkana Y
J Glaucoma; 2014 Jan; 23(1):e23-8. PubMed ID: 24370809
[TBL] [Abstract][Full Text] [Related]
28. Effect of central corneal thickness and radius of the corneal curvature on intraocular pressure measured with the Tono-Pen and noncontact tonometer in healthy schoolchildren.
Yildirim N; Sahin A; Basmak H; Bal C
J Pediatr Ophthalmol Strabismus; 2007; 44(4):216-22. PubMed ID: 17694826
[TBL] [Abstract][Full Text] [Related]
29. Positive correlation between Tono-Pen intraocular pressure and central corneal thickness.
Dohadwala AA; Munger R; Damji KF
Ophthalmology; 1998 Oct; 105(10):1849-54. PubMed ID: 9787354
[TBL] [Abstract][Full Text] [Related]
30. The Icare-Pro Rebound Tonometer Versus the Hand-held Applanation Tonometer in Congenital Glaucoma.
Borrego Sanz L; Morales-Fernandez L; Martínez de-la-Casa JM; Sáenz-Francés F; Fuentes M; García-Feijóo J
J Glaucoma; 2016 Feb; 25(2):149-54. PubMed ID: 25333612
[TBL] [Abstract][Full Text] [Related]
31. Agreement of rebound tonometer in measuring intraocular pressure with three types of applanation tonometers.
Nakamura M; Darhad U; Tatsumi Y; Fujioka M; Kusuhara A; Maeda H; Negi A
Am J Ophthalmol; 2006 Aug; 142(2):332-4. PubMed ID: 16876523
[TBL] [Abstract][Full Text] [Related]
32. Comparison of IOP Measurement by Goldmann Applanation Tonometer, ICare Rebound Tonometer, and Tono-Pen in Keratoconus Patients after MyoRing Implantation.
Rateb M; Abdel-Radi M; Eldaly Z; Elmohamady MN; Noor El Din A
J Ophthalmol; 2019; 2019():1964107. PubMed ID: 31210982
[TBL] [Abstract][Full Text] [Related]
33. Comparison of posture-induced intraocular pressure changes in medically treated and surgically treated eyes with open-angle glaucoma.
Sawada A; Yamamoto T
Invest Ophthalmol Vis Sci; 2014 Jan; 55(1):446-50. PubMed ID: 24398092
[TBL] [Abstract][Full Text] [Related]
34. Comparison of Three Different Tonometers in Eyes with Angle Closure.
Lee TE; Yoo C; Kim YY
Optom Vis Sci; 2019 Feb; 96(2):124-129. PubMed ID: 30589761
[TBL] [Abstract][Full Text] [Related]
35. Assessment of IcareONE rebound tonometer for self-measuring intraocular pressure.
Sakamoto M; Kanamori A; Fujihara M; Yamada Y; Nakamura M; Negi A
Acta Ophthalmol; 2014 May; 92(3):243-8. PubMed ID: 23586927
[TBL] [Abstract][Full Text] [Related]
36. Intraocular pressure curves of untreated glaucoma suspects and glaucoma patients in sitting and lateral decubitus positions using the goldmann applanation tonometer.
Piven I; Glovinsky Y
J Glaucoma; 2014; 23(8):541-6. PubMed ID: 25055215
[TBL] [Abstract][Full Text] [Related]
37. Comparison of intraocular pressure measurements between the Tono-Pen XL® and Perkins® applanation tonometers in dogs and cats.
Andrade SF; Palozzi RJ; Giuffrida R; de Campos RJ; Santos Gde C; Fukui RM
Vet Ophthalmol; 2012 Mar; 15 Suppl 1():14-20. PubMed ID: 22050624
[TBL] [Abstract][Full Text] [Related]
38. Comparison of Icare Rebound Tonometer and Perkins Applanation Tonometer in Community Eye Screening.
Ting SL; Lim LT; Ooi CY; Rahman MM
Asia Pac J Ophthalmol (Phila); 2019; 8(3):229-232. PubMed ID: 31165604
[TBL] [Abstract][Full Text] [Related]
39. The influence of central corneal thickness and corneal curvature on intraocular pressure measured by tono-pen and rebound tonometer in children.
Sahin A; Basmak H; Yildirim N
J Glaucoma; 2008; 17(1):57-61. PubMed ID: 18303387
[TBL] [Abstract][Full Text] [Related]
40. The influence of central corneal thickness and age on intraocular pressure measured by pneumotonometry, non-contact tonometry, the Tono-Pen XL, and Goldmann applanation tonometry.
Tonnu PA; Ho T; Newson T; El Sheikh A; Sharma K; White E; Bunce C; Garway-Heath D
Br J Ophthalmol; 2005 Jul; 89(7):851-4. PubMed ID: 15965165
[TBL] [Abstract][Full Text] [Related]
[Previous] [Next] [New Search]