126 related articles for article (PubMed ID: 25273769)
81. ENEA Reference Atmosphere Facility for Testing Radon and Daughters Measuring Equipment. Sciocchetti G; Scacco F; Tosti S; Baldassini PG; Soldano E J Res Natl Inst Stand Technol; 1990; 95(2):139-142. PubMed ID: 28179766 [TBL] [Abstract][Full Text] [Related]
82. Experimental verification of the attachment theory of radon progeny onto ambient aerosols. Tokonami S Health Phys; 2000 Jan; 78(1):74-9. PubMed ID: 10608313 [TBL] [Abstract][Full Text] [Related]
83. U.K. National Radiological Protection Board Radon Calibration Procedures. Cliff KD J Res Natl Inst Stand Technol; 1990; 95(2):135-138. PubMed ID: 28179765 [TBL] [Abstract][Full Text] [Related]
84. Methods for the experimental study of Mitev K; Cassette P; Pressyanov D; Georgiev S; Dutsov C; Michielsen N; Sabot B Appl Radiat Isot; 2020 Nov; 165():109259. PubMed ID: 32938534 [TBL] [Abstract][Full Text] [Related]
86. Radon daughter plateout--I. Measurements. George AC; Knutson EO; Tu KW Health Phys; 1983 Aug; 45(2):439-44. PubMed ID: 6885448 [TBL] [Abstract][Full Text] [Related]
87. Development of a high-sensitivity radon monitor for a radon calibration system at KRISS. Hwang SH; Han MJ; Seon YG; Lee JM; Lee KB Appl Radiat Isot; 2020 Oct; 164():109228. PubMed ID: 32554121 [TBL] [Abstract][Full Text] [Related]
88. Radon-222 Charcoal Canister Steady State Model Calibrations Performed in a Highly Controlled Environmental Chamber and a Natural Indoor Environment. Kennings TW; Noey JD; Mata LA; Kearfott KJ Health Phys; 2022 Sep; 123(3):248-256. PubMed ID: 35638913 [TBL] [Abstract][Full Text] [Related]
89. Calculating the calibration coefficient for radon measurements with the bare LR 115-II track detector. Nikezić D; Marković P; Uzarov DB Health Phys; 1992 Mar; 62(3):239-44. PubMed ID: 1735644 [TBL] [Abstract][Full Text] [Related]
91. Determination of the characteristic limits and responses of nuclear track detectors in mixed radon and thoron atmospheres. Röttger A; Honig A; Schrammel D; Strauss HF Appl Radiat Isot; 2016 Mar; 109():330-334. PubMed ID: 26671794 [TBL] [Abstract][Full Text] [Related]
92. Calibration of Electret-Based Integral Radon Monitors Using NIST Polyethylene-Encapsulated Collé R; Kotrappa P; Hutchinson JMR J Res Natl Inst Stand Technol; 1995; 100(6):629-639. PubMed ID: 29151765 [TBL] [Abstract][Full Text] [Related]
93. PM1, PM2.5 and PM10 size fraction distribution under steady-state conditions in a walk-in type 222Rn calibration chamber facility. Vijith AP; Mayya YS; Mishra R; Sapra BK; Karunakara N Radiat Prot Dosimetry; 2023 Dec; 199(20):2401-2405. PubMed ID: 38126869 [TBL] [Abstract][Full Text] [Related]
94. [Design and evaluation of an aerosol nanoparticle generation system]. Mai HJ; Jiang JK; He ZX; Hao JM Huan Jing Ke Xue; 2013 Aug; 34(8):2950-4. PubMed ID: 24191534 [TBL] [Abstract][Full Text] [Related]
95. In vivo measurement of unattached radon progeny deposited in the human respiratory tract. Butterweck G; Vezzù G; Schuler C; Müller R; Marsh JW; Thrift S; Birchall A Radiat Prot Dosimetry; 2001; 94(3):247-50. PubMed ID: 11487807 [TBL] [Abstract][Full Text] [Related]
97. An innovative technique of harvesting soil gas as a highly efficient source of Karunakara N; Shetty T; Sahoo BK; Kumara KS; Sapra BK; Mayya YS Sci Rep; 2020 Oct; 10(1):16547. PubMed ID: 33024139 [TBL] [Abstract][Full Text] [Related]
98. Development of a thoron calibration chamber based on computational fluid dynamics simulation and validation with measurements. Adelikhah M; Imani M; Kovács T Sci Rep; 2023 Aug; 13(1):13611. PubMed ID: 37604958 [TBL] [Abstract][Full Text] [Related]
99. Rn-222 and Rn-222 progeny in the human body: effect on in vivo K-40 measurements. Lykken G; Ong W; Patrick D; Wielopolski L Basic Life Sci; 1990; 55():361-3. PubMed ID: 2088293 [No Abstract] [Full Text] [Related]
100. Inspection of feasible calibration conditions for UV radiometer detectors with the KI/KIO3 actinometer. Qiang Z; Li W; Li M; Bolton JR; Qu J Photochem Photobiol; 2015; 91(1):68-73. PubMed ID: 25283349 [TBL] [Abstract][Full Text] [Related] [Previous] [Next] [New Search]