These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
337 related articles for article (PubMed ID: 25279806)
1. A novel and effective surface design: conducting polymer/β-cyclodextrin host-guest system for cholesterol biosensor. Soylemez S; Hacioglu SO; Kesik M; Unay H; Cirpan A; Toppare L ACS Appl Mater Interfaces; 2014 Oct; 6(20):18290-300. PubMed ID: 25279806 [TBL] [Abstract][Full Text] [Related]
2. A sepiolite modified conducting polymer based biosensor. Soylemez S; Kanik FE; Tarkuc S; Udum YA; Toppare L Colloids Surf B Biointerfaces; 2013 Nov; 111():549-55. PubMed ID: 23893029 [TBL] [Abstract][Full Text] [Related]
3. Development of a novel biosensor based on a conducting polymer. Soylemez S; Ekiz Kanik F; Ileri M; Hacioglu SO; Toppare L Talanta; 2014 Jan; 118():84-9. PubMed ID: 24274273 [TBL] [Abstract][Full Text] [Related]
4. A novel promising biomolecule immobilization matrix: synthesis of functional benzimidazole containing conducting polymer and its biosensor applications. Uzun SD; Unlu NA; Sendur M; Kanik FE; Timur S; Toppare L Colloids Surf B Biointerfaces; 2013 Dec; 112():74-80. PubMed ID: 23973906 [TBL] [Abstract][Full Text] [Related]
5. Cholesterol biosensor based on electrophoretically deposited conducting polymer film derived from nano-structured polyaniline colloidal suspension. Dhand C; Singh SP; Arya SK; Datta M; Malhotra BD Anal Chim Acta; 2007 Oct; 602(2):244-51. PubMed ID: 17933610 [TBL] [Abstract][Full Text] [Related]
6. Selenium containing conducting polymer based pyranose oxidase biosensor for glucose detection. Gokoglan TC; Soylemez S; Kesik M; Toksabay S; Toppare L Food Chem; 2015 Apr; 172():219-24. PubMed ID: 25442546 [TBL] [Abstract][Full Text] [Related]
7. Electrochemical polymerization of (2-dodecyl-4, 7-di (thiophen-2-yl)-2H-benzo[d][1,2,3] triazole): a novel matrix for biomolecule immobilization. Ekiz F; Yuksel M; Balan A; Timur S; Toppare L Macromol Biosci; 2010 Dec; 10(12):1557-65. PubMed ID: 20957699 [TBL] [Abstract][Full Text] [Related]
8. Development of a novel biosensor based on a polypyrrole-dodecylbenzene sulphonate (PPy-DBS) film for the determination of amperometric cholesterol. Özer BO; Çete S Artif Cells Nanomed Biotechnol; 2017 Jun; 45(4):824-832. PubMed ID: 27571602 [TBL] [Abstract][Full Text] [Related]
9. Polythiophene-g-poly(ethylene glycol) with Lateral Amino Groups as a Novel Matrix for Biosensor Construction. Akbulut H; Bozokalfa G; Asker DN; Demir B; Guler E; Odaci Demirkol D; Timur S; Yagci Y ACS Appl Mater Interfaces; 2015 Sep; 7(37):20612-22. PubMed ID: 26323569 [TBL] [Abstract][Full Text] [Related]
10. Construction and amperometric biosensing performance of a novel platform containing carbon nanotubes-zinc phthalocyanine and a conducting polymer. Buber E; Yuzer A; Soylemez S; Kesik M; Ince M; Toppare L Int J Biol Macromol; 2017 Mar; 96():61-69. PubMed ID: 27979729 [TBL] [Abstract][Full Text] [Related]
11. An amperometric bienzymatic cholesterol biosensor based on functionalized graphene modified electrode and its electrocatalytic activity towards total cholesterol determination. Manjunatha R; Shivappa Suresh G; Melo JS; D'Souza SF; Venkatesha TV Talanta; 2012 Sep; 99():302-9. PubMed ID: 22967556 [TBL] [Abstract][Full Text] [Related]
12. An amperometric acetylcholine biosensor based on a conducting polymer. Kanik FE; Kolb M; Timur S; Bahadir M; Toppare L Int J Biol Macromol; 2013 Aug; 59():111-8. PubMed ID: 23603072 [TBL] [Abstract][Full Text] [Related]
13. A highly sensitive electrochemical biosensor for catechol using conducting polymer reduced graphene oxide-metal oxide enzyme modified electrode. Sethuraman V; Muthuraja P; Anandha Raj J; Manisankar P Biosens Bioelectron; 2016 Oct; 84():112-9. PubMed ID: 26751827 [TBL] [Abstract][Full Text] [Related]
14. Glucose biosensor based on immobilization of glucose oxidase in poly(o-aminophenol) film on polypyrrole-Pt nanocomposite modified glassy carbon electrode. Li J; Lin X Biosens Bioelectron; 2007 Jun; 22(12):2898-905. PubMed ID: 17215117 [TBL] [Abstract][Full Text] [Related]
15. Enzyme entrapment by β-cyclodextrin electropolymerization onto a carbon nanotubes-modified screen-printed electrode. Alarcón-Ángeles G; Guix M; Silva WC; Ramírez-Silva MT; Palomar-Pardavé M; Romero-Romo M; Merkoçi A Biosens Bioelectron; 2010 Dec; 26(4):1768-73. PubMed ID: 20863684 [TBL] [Abstract][Full Text] [Related]
16. Covalent immobilization of cholesterol oxidase on self-assembled gold nanoparticles for highly sensitive amperometric detection of cholesterol in real samples. Saxena U; Chakraborty M; Goswami P Biosens Bioelectron; 2011 Feb; 26(6):3037-43. PubMed ID: 21195602 [TBL] [Abstract][Full Text] [Related]
17. Bioactive surface design based on functional composite electrospun nanofibers for biomolecule immobilization and biosensor applications. Uzun SD; Kayaci F; Uyar T; Timur S; Toppare L ACS Appl Mater Interfaces; 2014 Apr; 6(7):5235-43. PubMed ID: 24660809 [TBL] [Abstract][Full Text] [Related]
18. A porous poly(acrylonitrile-co-acrylic acid) film-based glucose biosensor constructed by electrochemical entrapment. Shan D; He Y; Wang S; Xue H; Zheng H Anal Biochem; 2006 Sep; 356(2):215-21. PubMed ID: 16842730 [TBL] [Abstract][Full Text] [Related]
19. A high-performance glucose biosensor using covalently immobilised glucose oxidase on a poly(2,6-diaminopyridine)/carbon nanotube electrode. Ali Kamyabi M; Hajari N; Turner AP; Tiwari A Talanta; 2013 Nov; 116():801-8. PubMed ID: 24148477 [TBL] [Abstract][Full Text] [Related]
20. Development of an amperometric sulfite biosensor based on SO(x)/PBNPs/PPY modified ITO electrode. Rawal R; Pundir CS Int J Biol Macromol; 2012 Nov; 51(4):449-55. PubMed ID: 22705572 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]