BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

203 related articles for article (PubMed ID: 25280335)

  • 1. Temperature controlled ionic liquid-based dispersive micro-extraction using two ligands, for determination of aluminium in scalp hair samples of Alzheimer's patients: a multivariate study.
    Arain MS; Arain SA; Kazi TG; Afridi HI; Ali J; Naeemulllah ; Arain SS; Brahman KD; Mughal MA
    Spectrochim Acta A Mol Biomol Spectrosc; 2015 Feb; 137():877-85. PubMed ID: 25280335
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Room temperature ionic liquid-based dispersive liquid phase microextraction for the separation/preconcentration of trace Cd(2+) as 1-(2-pyridylazo)-2-naphthol (PAN) complex from environmental and biological samples and determined by FAAS.
    Khan S; Soylak M; Kazi TG
    Biol Trace Elem Res; 2013 Dec; 156(1-3):49-55. PubMed ID: 24197606
    [TBL] [Abstract][Full Text] [Related]  

  • 3. A novel microextraction technique based on 1-hexylpyridinium hexafluorophosphate ionic liquid for the preconcentration of zinc in water and milk samples.
    Abdolmohammad-Zadeh H; Sadeghi GH
    Anal Chim Acta; 2009 Sep; 649(2):211-7. PubMed ID: 19699396
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Combination of ionic liquid-based dispersive liquid-liquid micro-extraction with stopped-flow spectrofluorometry for the pre-concentration and determination of aluminum in natural waters, fruit juice and food samples.
    Abdolmohammad-Zadeh H; Sadeghi GH
    Talanta; 2010 May; 81(3):778-85. PubMed ID: 20298853
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Ionic liquid-linked dual magnetic microextraction of lead(II) from environmental samples prior to its micro-sampling flame atomic absorption spectrometric determination.
    Yilmaz E; Soylak M
    Talanta; 2013 Nov; 116():882-6. PubMed ID: 24148489
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Estimation of lead in biological samples of oral cancer patients chewing smokeless tobacco products by ionic liquid-based microextraction in a single syringe system.
    Arain SS; Kazi TG; Arain AJ; Afridi HI; Arain MB; Brahman KD; Naeemullah ; Panhwar AH; Arain MS
    Environ Sci Pollut Res Int; 2015 Aug; 22(16):12396-406. PubMed ID: 25903188
    [TBL] [Abstract][Full Text] [Related]  

  • 7. A new dispersive liquid-liquid microextraction using ionic liquid based microemulsion coupled with cloud point extraction for determination of copper in serum and water samples.
    Arain SA; Kazi TG; Afridi HI; Arain MS; Panhwar AH; Khan N; Baig JA; Shah F
    Ecotoxicol Environ Saf; 2016 Apr; 126():186-192. PubMed ID: 26761783
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Ultra-trace determination of lead in water and food samples by using ionic liquid-based single drop microextraction-electrothermal atomic absorption spectrometry.
    Manzoori JL; Amjadi M; Abulhassani J
    Anal Chim Acta; 2009 Jun; 644(1-2):48-52. PubMed ID: 19463561
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Separation/preconcentration methods for the determination of aluminum in dialysate solution and scalp hair samples of kidney failure patients.
    Khan S; Kazi TG; Baig JA; Afridi HI; Kolachi NF
    Biol Trace Elem Res; 2011 Dec; 144(1-3):205-16. PubMed ID: 21573872
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Ultrasonically Dispersed Ionic Liquid-Based Microextraction of Lead in Biological Samples of Malnourished Children Prior to Analysis by Flame Atomic Absorption Spectrometry.
    Talpur S; Kazi TG; Afridi HI; Talpur FN; Nizamani S; Lashari A; Akhtar A; Khan M
    J AOAC Int; 2018 May; 101(3):883-890. PubMed ID: 28927487
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Application of response surface methodology for optimization of ionic liquid-based dispersive liquid-liquid microextraction of cadmium from water samples.
    Rajabi M; Kamalabadi M; Jamali MR; Zolgharnein J; Asanjarani N
    Hum Exp Toxicol; 2013 Jun; 32(6):620-31. PubMed ID: 22893353
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Generation of volatile copper species after in situ ionic liquid formation dispersive liquid-liquid microextraction prior to atomic absorption spectrometric detection.
    Stanisz E; Zgoła-Grześkowiak A; Matusiewicz H
    Talanta; 2014 Nov; 129():254-62. PubMed ID: 25127592
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Temperature-controlled ionic liquid-based ultrasound-assisted microextraction for preconcentration of trace quantity of cadmium and nickel by using organic ligand in artificial saliva extract of smokeless tobacco products.
    Arain SS; Kazi TG; Arain AJ; Afridi HI; Baig JA; Brahman KD; Naeemullah ; Arain SA
    Spectrochim Acta A Mol Biomol Spectrosc; 2015 Mar; 138():387-94. PubMed ID: 25523044
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Extraction and preconcentration of trace Al and Cr from vegetable samples by vortex-assisted ionic liquid-based dispersive liquid-liquid microextraction prior to atomic absorption spectrometric determination.
    Altunay N; Yıldırım E; Gürkan R
    Food Chem; 2018 Apr; 245():586-594. PubMed ID: 29287413
    [TBL] [Abstract][Full Text] [Related]  

  • 15. In situ metathesis ionic liquid formation dispersive liquid-liquid microextraction for copper determination in water samples by electrothermal atomic absorption spectrometry.
    Stanisz E; Zgoła-Grześkowiak A
    Talanta; 2013 Oct; 115():178-83. PubMed ID: 24054576
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Magnetic stirrer induced dispersive ionic-liquid microextraction for the determination of vanadium in water and food samples prior to graphite furnace atomic absorption spectrometry.
    Naeemullah ; Kazi TG; Tuzen M
    Food Chem; 2015 Apr; 172():161-5. PubMed ID: 25442538
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Development of a new green non-dispersive ionic liquid microextraction method in a narrow glass column for determination of cadmium prior to couple with graphite furnace atomic absorption spectrometry.
    Naeemullah ; Kazi TG; Tuzen M; Shah F; Afridi HI; Citak D
    Anal Chim Acta; 2014 Feb; 812():59-64. PubMed ID: 24491765
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Dispersive liquid-liquid microextraction and preconcentration of thallium species in water samples by two ionic liquids applied as ion-pairing reagent and extractant phase.
    Escudero LB; Berton P; Martinis EM; Olsina RA; Wuilloud RG
    Talanta; 2012 Jan; 88():277-83. PubMed ID: 22265499
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Sequential injection ionic liquid dispersive liquid-liquid microextraction for thallium preconcentration and determination with flame atomic absorption spectrometry.
    Anthemidis AN; Ioannou KI
    Anal Bioanal Chem; 2012 Aug; 404(3):685-91. PubMed ID: 22281679
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Rapid ionic liquid-based ultrasound assisted dual magnetic microextraction to preconcentrate and separate cadmium-4-(2-thiazolylazo)-resorcinol complex from environmental and biological samples.
    Khan S; Kazi TG; Soylak M
    Spectrochim Acta A Mol Biomol Spectrosc; 2014 Apr; 123():194-9. PubMed ID: 24398463
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 11.