334 related articles for article (PubMed ID: 25281943)
1. Quantifying the effect of seed orientation in postplanning dosimetry of low-dose-rate prostate brachytherapy.
Collins Fekete CA; Plamondon M; Martin AG; Vigneault É; Verhaegen F; Beaulieu L
Med Phys; 2014 Oct; 41(10):101704. PubMed ID: 25281943
[TBL] [Abstract][Full Text] [Related]
2. Prostate brachytherapy postimplant dosimetry: seed orientation and the impact of dosimetric anisotropy in stranded implants.
Chng N; Spadinger I; Rasoda R; Morris WJ; Salcudean S
Med Phys; 2012 Feb; 39(2):721-31. PubMed ID: 22320782
[TBL] [Abstract][Full Text] [Related]
3. Dosimetric and radiobiological investigation of permanent implant prostate brachytherapy based on Monte Carlo calculations.
Haidari AM; Miksys N; Soubiran P; Cygler JE; Holmes O; Perry G; Thomson RM
Brachytherapy; 2019; 18(6):875-882. PubMed ID: 31400953
[TBL] [Abstract][Full Text] [Related]
4. Dosimetry accuracy as a function of seed localization uncertainty in permanent prostate brachytherapy: increased seed number correlates with less variability in prostate dosimetry.
Su Y; Davis BJ; Furutani KM; Herman MG; Robb RA
Phys Med Biol; 2007 Jun; 52(11):3105-19. PubMed ID: 17505092
[TBL] [Abstract][Full Text] [Related]
5. Monte Carlo study of LDR seed dosimetry with an application in a clinical brachytherapy breast implant.
Furstoss C; Reniers B; Bertrand MJ; Poon E; Carrier JF; Keller BM; Pignol JP; Beaulieu L; Verhaegen F
Med Phys; 2009 May; 36(5):1848-58. PubMed ID: 19544804
[TBL] [Abstract][Full Text] [Related]
6. Calcifications in low-dose rate prostate seed brachytherapy treatment: post-planning dosimetry and predictive factors.
Collins Fekete CA; Plamondon M; Martin AG; Vigneault É; Verhaegen F; Beaulieu L
Radiother Oncol; 2015 Mar; 114(3):339-44. PubMed ID: 25702862
[TBL] [Abstract][Full Text] [Related]
7. Sensitivity of low energy brachytherapy Monte Carlo dose calculations to uncertainties in human tissue composition.
Landry G; Reniers B; Murrer L; Lutgens L; Gurp EB; Pignol JP; Keller B; Beaulieu L; Verhaegen F
Med Phys; 2010 Oct; 37(10):5188-98. PubMed ID: 21089752
[TBL] [Abstract][Full Text] [Related]
8. Influence of source batch S dispersion on dosimetry for prostate cancer treatment with permanent implants.
Nuñez-Cumplido E; Perez-Calatayud J; Casares-Magaz O; Hernandez-Armas J
Med Phys; 2015 Aug; 42(8):4933-40. PubMed ID: 26233219
[TBL] [Abstract][Full Text] [Related]
9. Dosimetric effects of seed anisotropy and interseed attenuation for 103Pd and 125I prostate implants.
Chibani O; Williamson JF; Todor D
Med Phys; 2005 Aug; 32(8):2557-66. PubMed ID: 16193786
[TBL] [Abstract][Full Text] [Related]
10. An evaluation of the AAPM-TG43 dosimetry protocol for I-125 brachytherapy seed.
Mobit P; Badragan I
Phys Med Biol; 2004 Jul; 49(14):3161-70. PubMed ID: 15357189
[TBL] [Abstract][Full Text] [Related]
11. Monte Carlo dosimetry of high dose rate gynecologic interstitial brachytherapy.
Desbiens M; D'Amours M; Afsharpour H; Verhaegen F; Lavallée MC; Thibault I; Vigneault É; Beaulieu L
Radiother Oncol; 2013 Dec; 109(3):425-9. PubMed ID: 24135700
[TBL] [Abstract][Full Text] [Related]
12. Loose versus stranded seeds in permanent prostate brachytherapy: dosimetric comparison of intraoperative plans.
Major T; Agoston P; Fröhlich G; Baricza K; Szabo Z; Jorgo K; Herein A; Polgar C
Phys Med; 2014 Dec; 30(8):909-13. PubMed ID: 25175151
[TBL] [Abstract][Full Text] [Related]
13. Monte Carlo calculated TG-43 dosimetry parameters for the SeedLink 125Iodine brachytherapy system.
Medich DC; Munro JJ
Med Phys; 2003 Sep; 30(9):2503-8. PubMed ID: 14528972
[TBL] [Abstract][Full Text] [Related]
14. Layered mass geometry: a novel technique to overlay seeds and applicators onto patient geometry in Geant4 brachytherapy simulations.
Enger SA; Landry G; D'Amours M; Verhaegen F; Beaulieu L; Asai M; Perl J
Phys Med Biol; 2012 Oct; 57(19):6269-77. PubMed ID: 22975747
[TBL] [Abstract][Full Text] [Related]
15. Tissue composition and density impact on the clinical parameters for (125)I prostate implants dosimetry.
Oliveira SM; Teixeira NJ; Fernandes L; Teles P; Vieira G; Vaz P
Phys Med; 2014 Nov; 30(7):799-808. PubMed ID: 25239870
[TBL] [Abstract][Full Text] [Related]
16. Evaluation of dosimetric effects of metallic artifact reduction and tissue assignment on Monte Carlo dose calculations for
Assam I; Vijande J; Ballester F; Pérez-Calatayud J; Poppe B; Siebert FA
Med Phys; 2022 Sep; 49(9):6195-6208. PubMed ID: 35925023
[TBL] [Abstract][Full Text] [Related]
17. Improved tissue assignment using dual-energy computed tomography in low-dose rate prostate brachytherapy for Monte Carlo dose calculation.
Côté N; Bedwani S; Carrier JF
Med Phys; 2016 May; 43(5):2611. PubMed ID: 27147370
[TBL] [Abstract][Full Text] [Related]
18. Dosimetric accuracy of a deterministic radiation transport based (192)Ir brachytherapy treatment planning system. Part III. Comparison to Monte Carlo simulation in voxelized anatomical computational models.
Zourari K; Pantelis E; Moutsatsos A; Sakelliou L; Georgiou E; Karaiskos P; Papagiannis P
Med Phys; 2013 Jan; 40(1):011712. PubMed ID: 23298082
[TBL] [Abstract][Full Text] [Related]
19. Advanced Collapsed cone Engine dose calculations in tissue media for COMS eye plaques loaded with I-125 seeds.
Morrison H; Menon G; Larocque MP; van Veelen B; Niatsetski Y; Weis E; Sloboda RS
Med Phys; 2018 Jul; 45(7):3349-3360. PubMed ID: 29729009
[TBL] [Abstract][Full Text] [Related]
20. Validation of GPUMCD for low-energy brachytherapy seed dosimetry.
Hissoiny S; Ozell B; Després P; Carrier JF
Med Phys; 2011 Jul; 38(7):4101-7. PubMed ID: 21859010
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]