These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

288 related articles for article (PubMed ID: 25283140)

  • 61. IFCC primary reference procedures for the measurement of catalytic activity concentrations of enzymes at 37 degrees C. International Federation of Clinical Chemistry and Laboratory Medicine. Part 5. Reference procedure for the measurement of catalytic concentration of aspartate aminotransferase.
    Schumann G; Bonora R; Ceriotti F; Férard G; Ferrero CA; Franck PF; Gella FJ; Hoelzel W; Jørgensen PJ; Kanno T; Kessner A; Klauke R; Kristiansen N; Lessinger JM; Linsinger TP; Misaki H; Panteghini M; Pauwels J; Schiele F; Schimmel HG; Weidemann G; Siekmann L;
    Clin Chem Lab Med; 2002 Jul; 40(7):725-33. PubMed ID: 12241022
    [TBL] [Abstract][Full Text] [Related]  

  • 62. Systematic comparison of δ13C measurements of testosterone and derivative steroids in a freeze-dried urine candidate reference material for sports drug testing by gas chromatography/combustion/isotope ratio mass spectrometry and uncertainty evaluation using four different metrological approaches.
    Munton E; Murby J; Hibbert DB; Santamaria-Fernandez R
    Rapid Commun Mass Spectrom; 2011 Jun; 25(11):1641-51. PubMed ID: 21594940
    [TBL] [Abstract][Full Text] [Related]  

  • 63. Defining acceptable limits for the metrological traceability of specific measurands.
    Bais R; Armbruster D; Jansen RT; Klee G; Panteghini M; Passarelli J; Sikaris KA;
    Clin Chem Lab Med; 2013 May; 51(5):973-9. PubMed ID: 23525873
    [TBL] [Abstract][Full Text] [Related]  

  • 64. Evaluation of uncertainty of measurement in routine clinical chemistry--applications to determination of the substance concentration of calcium and glucose in serum.
    Linko S; Ornemark U; Kessel R; Taylor PD
    Clin Chem Lab Med; 2002 Apr; 40(4):391-8. PubMed ID: 12059081
    [TBL] [Abstract][Full Text] [Related]  

  • 65. Standardization in clinical enzymology: a challenge for the theory of metrological traceability.
    Infusino I; Schumann G; Ceriotti F; Panteghini M
    Clin Chem Lab Med; 2010 Mar; 48(3):301-7. PubMed ID: 20113251
    [TBL] [Abstract][Full Text] [Related]  

  • 66. Measurement uncertainty for practical use.
    Coskun A; Theodorsson E; Oosterhuis WP; Sandberg S;
    Clin Chim Acta; 2022 Jun; 531():352-360. PubMed ID: 35513038
    [TBL] [Abstract][Full Text] [Related]  

  • 67. IFCC Working Group Recommendations for Assessing Commutability Part 2: Using the Difference in Bias between a Reference Material and Clinical Samples.
    Nilsson G; Budd JR; Greenberg N; Delatour V; Rej R; Panteghini M; Ceriotti F; Schimmel H; Weykamp C; Keller T; Camara JE; Burns C; Vesper HW; MacKenzie F; Miller WG;
    Clin Chem; 2018 Mar; 64(3):455-464. PubMed ID: 29348165
    [TBL] [Abstract][Full Text] [Related]  

  • 68. Documenting metrological traceability as intended by ISO 15189:2012: A consensus statement about the practice of the implementation and auditing of this norm element.
    Thelen M; Vanstapel F; Brguljan PM; Gouget B; Boursier G; Barrett E; Kroupis C; Lohmander M; Šprongl L; Vodnik T; Bernabeu-Andreu F; Vukasović I; Sönmez Ç; Linko S; Brugnoni D; Vaubourdolle M; Huisman W; Panteghini M;
    Clin Chem Lab Med; 2019 Mar; 57(4):459-464. PubMed ID: 30511927
    [TBL] [Abstract][Full Text] [Related]  

  • 69. Estimation of MU for Glucose in Human Serum Using Bottom-up Approach.
    Tao Y; Dai H; Chen F; Zhou W; Shen L; Wang H; Ju S
    Clin Lab; 2020 Dec; 66(12):. PubMed ID: 33337840
    [TBL] [Abstract][Full Text] [Related]  

  • 70. Bias and Uncertainty in Non-Ideal qNMR Analysis.
    Le Gresley A; Fardus F; Warren J
    Crit Rev Anal Chem; 2015; 45(4):300-10. PubMed ID: 25996029
    [TBL] [Abstract][Full Text] [Related]  

  • 71. Proposal of a candidate international conventional reference measurement procedure for free thyroxine in serum.
    ; Thienpont LM; Beastall G; Christofides ND; Faix JD; Ieiri T; Jarrige V; Miller WG; Miller R; Nelson JC; Ronin C; Ross HA; Rottmann M; Thijssen JH; Toussaint B
    Clin Chem Lab Med; 2007; 45(7):934-6. PubMed ID: 17617044
    [TBL] [Abstract][Full Text] [Related]  

  • 72. Permissible limits for uncertainty of measurement in laboratory medicine.
    Haeckel R; Wosniok W; Gurr E; Peil B
    Clin Chem Lab Med; 2015 Jul; 53(8):1161-71. PubMed ID: 25720082
    [TBL] [Abstract][Full Text] [Related]  

  • 73. A method to estimate the uncertainty of measurements in a conglomerate of instruments/laboratories.
    Kallner A; Khorovskaya L; Pettersson T
    Scand J Clin Lab Invest; 2005; 65(7):551-8. PubMed ID: 16271986
    [TBL] [Abstract][Full Text] [Related]  

  • 74. The Guide to expression of uncertainty in measurement approach for estimating uncertainty: an appraisal.
    Kristiansen J
    Clin Chem; 2003 Nov; 49(11):1822-9. PubMed ID: 14578313
    [TBL] [Abstract][Full Text] [Related]  

  • 75. Uncertainty of (222)Rn concentrations in the usepa radiation and indoor environments National Laboratory Exposure Chamber.
    Ronca-Battista M; Budd G; McLemore S
    Health Phys; 2013 Feb; 104(2):168-78. PubMed ID: 23274820
    [TBL] [Abstract][Full Text] [Related]  

  • 76. Managing quality vs. measuring uncertainty in the medical laboratory.
    Westgard JO
    Clin Chem Lab Med; 2010; 48(1):31-40. PubMed ID: 19919330
    [TBL] [Abstract][Full Text] [Related]  

  • 77. Result, error and uncertainty.
    Dybkaer R
    Scand J Clin Lab Invest; 1995 Apr; 55(2):97-118. PubMed ID: 7667613
    [TBL] [Abstract][Full Text] [Related]  

  • 78. Establishing a reference system in clinical enzymology.
    Panteghini M; Ceriotti F; Schumann G; Siekmann L
    Clin Chem Lab Med; 2001 Sep; 39(9):795-800. PubMed ID: 11601675
    [TBL] [Abstract][Full Text] [Related]  

  • 79. Uncertainty of measurement: an immunology laboratory perspective.
    Beck SC; Lock RJ
    Ann Clin Biochem; 2015 Jan; 52(Pt 1):7-17. PubMed ID: 25161319
    [TBL] [Abstract][Full Text] [Related]  

  • 80. The top-down approach to measurement uncertainty: which formula should we use in laboratory medicine?
    Martinello F; Snoj N; Skitek M; Jerin A
    Biochem Med (Zagreb); 2020 Jun; 30(2):020101. PubMed ID: 32292278
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 15.