These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
170 related articles for article (PubMed ID: 25284220)
1. Continuous flow left ventricular pump support and its effect on regional left ventricular wall stress: finite element analysis study. Jhun CS; Sun K; Cysyk JP Med Biol Eng Comput; 2014 Dec; 52(12):1031-40. PubMed ID: 25284220 [TBL] [Abstract][Full Text] [Related]
2. Assessment of myocardial viability and left ventricular function in patients supported by a left ventricular assist device. Gupta DK; Skali H; Rivero J; Campbell P; Griffin L; Smith C; Foster C; Claggett B; Glynn RJ; Couper G; Givertz MM; Mehra MR; Di Carli M; Solomon SD; Pfeffer MA J Heart Lung Transplant; 2014 Apr; 33(4):372-81. PubMed ID: 24582837 [TBL] [Abstract][Full Text] [Related]
4. Effective ventricular unloading by left ventricular assist device varies with stage of heart failure: cardiac simulator study. Jhun CS; Reibson JD; Cysyk JP ASAIO J; 2011; 57(5):407-13. PubMed ID: 21817896 [TBL] [Abstract][Full Text] [Related]
5. Rotary pump speed modulation for generating pulsatile flow and phasic left ventricular volume unloading in a bovine model of chronic ischemic heart failure. Soucy KG; Giridharan GA; Choi Y; Sobieski MA; Monreal G; Cheng A; Schumer E; Slaughter MS; Koenig SC J Heart Lung Transplant; 2015 Jan; 34(1):122-131. PubMed ID: 25447573 [TBL] [Abstract][Full Text] [Related]
6. Left Ventricular Assist Device Flow Pattern Analysis Using a Novel Model Incorporating Left Ventricular Pulsatility. Grinstein J; Torii R; Bourantas CV; Garcia-Garcia HM ASAIO J; 2021 Jul; 67(7):724-732. PubMed ID: 33528162 [TBL] [Abstract][Full Text] [Related]
7. An in silico study of the effects of left ventricular assist device on right ventricular function and inter-ventricular interaction. Fan L; Choy JS; Lee S; Campbell KS; Wenk JF; Kassab GS; Burkhoff D; Lee LC Artif Organs; 2023 Dec; 47(12):1831-1847. PubMed ID: 37746896 [TBL] [Abstract][Full Text] [Related]
8. Left ventricular assist device weaning: hemodynamic response and relationship to stroke volume and rate reduction protocols. Slaughter MS; Sobieski MA; Koenig SC; Pappas PS; Tatooles AJ; Silver MA ASAIO J; 2006; 52(3):228-33. PubMed ID: 16760709 [TBL] [Abstract][Full Text] [Related]
9. Magnitude and time course of changes induced by continuous-flow left ventricular assist device unloading in chronic heart failure: insights into cardiac recovery. Drakos SG; Wever-Pinzon O; Selzman CH; Gilbert EM; Alharethi R; Reid BB; Saidi A; Diakos NA; Stoker S; Davis ES; Movsesian M; Li DY; Stehlik J; Kfoury AG; J Am Coll Cardiol; 2013 May; 61(19):1985-94. PubMed ID: 23500219 [TBL] [Abstract][Full Text] [Related]
10. The effect of heart failure and left ventricular assist device treatment on right ventricular mechanics: a computational study. Park JIK; Heikhmakhtiar AK; Kim CH; Kim YS; Choi SW; Song KS; Lim KM Biomed Eng Online; 2018 May; 17(1):62. PubMed ID: 29784052 [TBL] [Abstract][Full Text] [Related]
11. In vitro hemodynamic characterization of HeartMate II at 6000 rpm: Implications for weaning and recovery. Sunagawa G; Byram N; Karimov JH; Horvath DJ; Moazami N; Starling RC; Fukamachi K J Thorac Cardiovasc Surg; 2015 Aug; 150(2):343-8. PubMed ID: 26204865 [TBL] [Abstract][Full Text] [Related]
12. Reproduction of continuous flow left ventricular assist device experimental data by means of a hybrid cardiovascular model with baroreflex control. Fresiello L; Zieliński K; Jacobs S; Di Molfetta A; Pałko KJ; Bernini F; Martin M; Claus P; Ferrari G; Trivella MG; Górczyńska K; Darowski M; Meyns B; Kozarski M Artif Organs; 2014 Jun; 38(6):456-68. PubMed ID: 24117988 [TBL] [Abstract][Full Text] [Related]
13. Residual stress produced by ventricular volume reduction surgery has little effect on ventricular function and mechanics: a finite element model study. Guccione JM; Moonly SM; Wallace AW; Ratcliffe MB J Thorac Cardiovasc Surg; 2001 Sep; 122(3):592-9. PubMed ID: 11547315 [TBL] [Abstract][Full Text] [Related]
14. Effect of adjustable passive constraint on the failing left ventricle: a finite-element model study. Jhun CS; Wenk JF; Zhang Z; Wall ST; Sun K; Sabbah HN; Ratcliffe MB; Guccione JM Ann Thorac Surg; 2010 Jan; 89(1):132-7. PubMed ID: 20103222 [TBL] [Abstract][Full Text] [Related]
15. Effects of left ventricular assist device on cardiac function: experimental study of relationship between pump flow and left ventricular diastolic function. Saito A; Shiono M; Orime Y; Yagi S; Nakata KI; Eda K; Hattori T; Funahashi M; Taniguchi Y; Negishi N; Sezai Y Artif Organs; 2001 Sep; 25(9):728-32. PubMed ID: 11722351 [TBL] [Abstract][Full Text] [Related]
16. Inadequate left ventricular unloading during ramp is associated with hospitalization or death during left ventricular assist device support. Rosenbaum AN; Stulak JM; Clavell AL; Behfar A Artif Organs; 2021 Feb; 45(2):115-123. PubMed ID: 32761951 [TBL] [Abstract][Full Text] [Related]
17. Ultrasound-based estimation of remaining cardiac function in LVAD-supported ex vivo hearts. Fixsen LS; Petterson NJ; Houthuizen P; Rutten MCM; van de Vosse FN; Lopata RGP Artif Organs; 2020 Aug; 44(8):E326-E336. PubMed ID: 32242944 [TBL] [Abstract][Full Text] [Related]
18. Effects of left ventricular pressure unloading during LVAD support on right ventricular contractility. Chow E; Brown CD; Farrar DJ ASAIO J; 1992; 38(3):M473-6. PubMed ID: 1457905 [TBL] [Abstract][Full Text] [Related]