2. Distribution of corneal densitometry in different grades of keratoconus. Mounir A; Awny I; Yousef HS; Mostafa EM Indian J Ophthalmol; 2023 Mar; 71(3):830-836. PubMed ID: 36872687 [TBL] [Abstract][Full Text] [Related]
3. Long-Term Changes in Backscattered Light Measurements in Keratoconus Corneas Treated with Collagen Cross-Linking. Nemeth G; Hassan J; Modis L; Hassan Z Curr Eye Res; 2018 Jan; 43(1):18-26. PubMed ID: 29111836 [TBL] [Abstract][Full Text] [Related]
4. Comparative evaluation of Scheimpflug tomography parameters between thin non-keratoconic, subclinical keratoconic, and mild keratoconic corneas. Huseynli S; Salgado-Borges J; Alio JL Eur J Ophthalmol; 2018 Sep; 28(5):521-534. PubMed ID: 29566542 [TBL] [Abstract][Full Text] [Related]
5. Corneal densitometry in high myopia. Dong J; Zhang Y; Zhang H; Jia Z; Zhang S; Sun B; Han Y; Wang X BMC Ophthalmol; 2018 Jul; 18(1):182. PubMed ID: 30045701 [TBL] [Abstract][Full Text] [Related]
6. Corneal Densitometry, Central Corneal Thickness, and Corneal Central-to-Peripheral Thickness Ratio in Patients With Fuchs Endothelial Dystrophy. Alnawaiseh M; Zumhagen L; Wirths G; Eveslage M; Eter N; Rosentreter A Cornea; 2016 Mar; 35(3):358-62. PubMed ID: 26655484 [TBL] [Abstract][Full Text] [Related]
7. Comparison of central corneal thickness measurements with a rotating scheimpflug camera, a specular microscope, optical low-coherence reflectometry, and ultrasound pachymetry in keratoconic eyes. Cinar Y; Cingu AK; Turkcu FM; Cinar T; Sahin A; Yuksel H; Ari S Semin Ophthalmol; 2015 Mar; 30(2):105-11. PubMed ID: 24171806 [TBL] [Abstract][Full Text] [Related]
8. Keratoconus Clinical Findings According to Different Classifications. Naderan M; Shoar S; Kamaleddin MA; Rajabi MT; Naderan M; Khodadadi M Cornea; 2015 Sep; 34(9):1005-11. PubMed ID: 26203749 [TBL] [Abstract][Full Text] [Related]
9. Evaluation of corneal elevation, pachymetry and keratometry in keratoconic eyes with respect to the stage of Amsler-Krumeich classification. Kamiya K; Ishii R; Shimizu K; Igarashi A Br J Ophthalmol; 2014 Apr; 98(4):459-63. PubMed ID: 24457362 [TBL] [Abstract][Full Text] [Related]
10. Intereye asymmetry detected by Scheimpflug imaging in subjects with normal corneas and keratoconus. Henriquez MA; Izquierdo L; Mannis MJ Cornea; 2013 Jun; 32(6):779-82. PubMed ID: 23263222 [TBL] [Abstract][Full Text] [Related]
11. Use of a support vector machine for keratoconus and subclinical keratoconus detection by topographic and tomographic data. Arbelaez MC; Versaci F; Vestri G; Barboni P; Savini G Ophthalmology; 2012 Nov; 119(11):2231-8. PubMed ID: 22892148 [TBL] [Abstract][Full Text] [Related]
12. Pentacam Scheimpflug tomography findings in topographically normal patients and subclinical keratoconus cases. Ruiseñor Vázquez PR; Galletti JD; Minguez N; Delrivo M; Fuentes Bonthoux F; Pförtner T; Galletti JG Am J Ophthalmol; 2014 Jul; 158(1):32-40.e2. PubMed ID: 24709808 [TBL] [Abstract][Full Text] [Related]
13. OCT-derived comparison of corneal thickness distribution and asymmetry differences between normal and keratoconic eyes. Kanellopoulos AJ; Asimellis G Cornea; 2014 Dec; 33(12):1274-81. PubMed ID: 25321940 [TBL] [Abstract][Full Text] [Related]
14. Comparative analysis of corneal measurements obtained from a Scheimpflug camera and an integrated Placido-optical coherence tomography device in normal and keratoconic eyes. Viswanathan D; Kumar NL; Males JJ; Graham SL Acta Ophthalmol; 2015 Sep; 93(6):e488-94. PubMed ID: 25495530 [TBL] [Abstract][Full Text] [Related]
15. An Early Finding of Keratoconus: Increase in Corneal Densitometry. Koc M; Tekin K; Tekin MI; Uzel MM; Kosekahya P; Ozulken K; Yilmazbas P Cornea; 2018 May; 37(5):580-586. PubMed ID: 29384807 [TBL] [Abstract][Full Text] [Related]
16. Determination of corneal volume from anterior topography and topographic pachymetry: application to healthy and keratoconic eyes. Cerviño A; Gonzalez-Meijome JM; Ferrer-Blasco T; Garcia-Resua C; Montes-Mico R; Parafita M Ophthalmic Physiol Opt; 2009 Nov; 29(6):652-60. PubMed ID: 19821928 [TBL] [Abstract][Full Text] [Related]
17. Scheimpflug Densitometry in Keratoconus: A New Method of Visualizing the Cone. Jiménez-García M; Ní Dhubhghaill S; Consejo A; Hershko S; Koppen C; Rozema JJ Cornea; 2021 Feb; 40(2):194-202. PubMed ID: 33065713 [TBL] [Abstract][Full Text] [Related]
18. Reliability of Pentacam HR Thickness Maps of the Entire Cornea in Normal, Post-Laser In Situ Keratomileusis, and Keratoconus Eyes. Xu Z; Peng M; Jiang J; Yang C; Zhu W; Lu F; Shen M Am J Ophthalmol; 2016 Feb; 162():74-82.e1. PubMed ID: 26556008 [TBL] [Abstract][Full Text] [Related]
19. Anterior chamber characteristics of keratoconus assessed by rotating Scheimpflug imaging. Kovács I; Miháltz K; Németh J; Nagy ZZ J Cataract Refract Surg; 2010 Jul; 36(7):1101-6. PubMed ID: 20610086 [TBL] [Abstract][Full Text] [Related]
20. Evaluation of keratometric, pachymetric, and elevation parameters of keratoconic corneas with pentacam. Miháltz K; Kovács I; Takács A; Nagy ZZ Cornea; 2009 Oct; 28(9):976-80. PubMed ID: 19724217 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]