BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

162 related articles for article (PubMed ID: 25289213)

  • 1. Transcutaneous PCO2 Measurement at Low Temperature for Reliable and Continuous Free Flap Monitoring: Experimental and Clinical Study.
    Abe Y; Hashimoto I; Goishi K; Kashiwagi K; Yamano M; Nakanishi H
    Plast Reconstr Surg Glob Open; 2013 May; 1(2):1-8. PubMed ID: 25289213
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Validation of a New Transcutaneous tcPO2/tcPCO2 Sensor with an Optical Oxygen Measurement in Preterm Neonates.
    van Weteringen W; van Essen T; Gangaram-Panday NH; Goos TG; de Jonge RCJ; Reiss IKM
    Neonatology; 2020; 117(5):628-636. PubMed ID: 32998134
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Novel transcutaneous sensor combining optical tcPO
    van Weteringen W; Goos TG; van Essen T; Ellenberger C; Hayoz J; de Jonge RCJ; Reiss IKM; Schumacher PM
    Med Biol Eng Comput; 2020 Feb; 58(2):239-247. PubMed ID: 31741291
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Transcutaneous blood gas monitoring among neonatal intensive care units in Japan.
    Ochiai M; Kurata H; Inoue H; Ichiyama M; Fujiyoshi J; Watabe S; Hiroma T; Nakamura T; Ohga S
    Pediatr Int; 2020 Feb; 62(2):169-174. PubMed ID: 31845473
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Effect of electrode temperature on measurements of transcutaneous carbon dioxide partial pressure and oxygen partial pressure in very low birth weight infants.
    Li BH; Zhao CL; Cao SL; Geng HL; Li JJ; Zhu M; Niu SP
    Zhongguo Dang Dai Er Ke Za Zhi; 2021 Aug; 23(8):809-813. PubMed ID: 34511170
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Transcutaneous oxygen and carbon dioxide pressure monitoring to determine severity of limb ischemia and to predict surgical outcome.
    Lalka SG; Malone JM; Anderson GG; Hagaman RM; McIntyre KE; Bernhard VM
    J Vasc Surg; 1988 Apr; 7(4):507-14. PubMed ID: 3352067
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Long-term transcutaneous monitoring of oxygen tension and carbon dioxide at 42 degrees C in critically ill neonates: improved performance of the tcpo2 monitor with topical metabolic inhibition.
    Fanconi S; Tschupp A; Molinari L
    Eur J Pediatr; 1996 Dec; 155(12):1043-6. PubMed ID: 8956942
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Validation of a new combined transcutaneous tcPCO
    van Wijk JJ; van Weteringen W; Hoeks SE; Staals LM
    Paediatr Anaesth; 2022 Mar; 32(3):429-435. PubMed ID: 34882905
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Transcutaneous oxygen and carbon dioxide measurements for determination of skin graft "take".
    Greenhalgh DG; Warden GD
    J Burn Care Rehabil; 1992; 13(3):334-9. PubMed ID: 1618878
    [TBL] [Abstract][Full Text] [Related]  

  • 10. The measurement of TcPO2 and TcPCO2 in newborn infants at 44 degrees C, 42 degrees C and 37 degrees C after initial heating to 44 degrees C.
    Friis-Hansen B; Voldsgaard P; Witt J; Pedersen KG; Frederiksen PS
    Adv Exp Med Biol; 1987; 220():35-40. PubMed ID: 3673782
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Quantitative analysis of hemodynamics of congested island flaps under leech therapy.
    Kashiwagi K; Hashimoto I; Abe Y; Kotsu K; Yamano M; Nakanishi H
    J Med Invest; 2013; 60(3-4):213-20. PubMed ID: 24190038
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Demonstrating the Potential of Using Transcutaneous Oxygen and Carbon Dioxide Tensions to Assess the Risk of Pressure Injuries.
    Xue M; Wang D; Zhang Z; Cao Z; Luo Z; Zheng Y; Lu J; Zhao Q; Zhang XD
    Int J Biol Sci; 2018; 14(11):1466-1471. PubMed ID: 30262998
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Transcutaneous oxygen and carbon dioxide monitoring in intensive care.
    Marsden D; Chiu MC; Paky F; Helms P
    Arch Dis Child; 1985 Dec; 60(12):1158-61. PubMed ID: 3937497
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Transcutaneous oxygen and carbon dioxide levels with iloprost administration in diabetic critical limb ischemia.
    Melillo E; Ferrari M; Balbarini A; Pedrinelli R
    Vasc Endovascular Surg; 2006; 40(4):303-11. PubMed ID: 16959724
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Transcutaneous measurement of carbon dioxide tension: effect of sleep state in term infants.
    Martin RJ; Herrell N; Pultusker M
    Pediatrics; 1981 May; 67(5):622-5. PubMed ID: 6789297
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Transcutaneous Carbon Dioxide Monitoring with Reduced-Temperature Probes in Very Low Birth Weight Infants.
    Aly S; El-Dib M; Mohamed M; Aly H
    Am J Perinatol; 2017 Apr; 34(5):480-485. PubMed ID: 27673754
    [No Abstract]   [Full Text] [Related]  

  • 17. [The effect of different types of anesthetic respirators on oxygenation and ventilation in infants during short-term anesthesia. A study using transcutaneous PO2 and PCO2 monitoring].
    Scheiber G; Hess W; Marichal A
    Anaesthesist; 1994 Aug; 43(8):510-20. PubMed ID: 7978174
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Measurement of transcutaneous pCO2 and pO2 in the fetus during labor.
    Schmidt S; Langner K; Dudenhausen JW; Saling E
    Arch Gynecol; 1985; 236(3):145-51. PubMed ID: 3925898
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Effect of electrode temperatures on monitoring of transcutaneous carbon dioxide (TcPCO2) in prematures.
    Vesterager P
    Biotelem Patient Monit; 1982; 9(1):18-27. PubMed ID: 6809069
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Comparison of transcutaneous oxygen and carbon dioxide monitors in normal adults and critically ill patients.
    Rithalia SV; Farrow P; Doran BR
    Intensive Crit Care Nurs; 1992 Mar; 8(1):40-6. PubMed ID: 1559023
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 9.