163 related articles for article (PubMed ID: 25291423)
1. Automated slice-specific simultaneous z-shim method for reducing B1 inhomogeneity and susceptibility-induced signal loss with parallel transmission at 3T.
Schneider R; Boada F; Haueisen J; Pfeuffer J
Magn Reson Med; 2015 Oct; 74(4):934-44. PubMed ID: 25291423
[TBL] [Abstract][Full Text] [Related]
2. Simultaneous z-shim method for reducing susceptibility artifacts with multiple transmitters.
Deng W; Yang C; Alagappan V; Wald LL; Boada FE; Stenger VA
Magn Reson Med; 2009 Feb; 61(2):255-9. PubMed ID: 19165881
[TBL] [Abstract][Full Text] [Related]
3. Simultaneous multislice spectral-spatial excitations for reduced signal loss susceptibility artifact in BOLD functional MRI.
Anderson RJ; Poser BA; Stenger VA
Magn Reson Med; 2014 Nov; 72(5):1342-52. PubMed ID: 24338863
[TBL] [Abstract][Full Text] [Related]
4. A 16-channel AC/DC array coil for anesthetized monkey whole-brain imaging at 7T.
Gao Y; Mareyam A; Sun Y; Witzel T; Arango N; Kuang I; White J; Roe AW; Wald L; Stockmann J; Zhang X
Neuroimage; 2020 Feb; 207():116396. PubMed ID: 31778818
[TBL] [Abstract][Full Text] [Related]
5. An efficient automated z-shim based method to correct through-slice signal loss in EPI at 3T.
Marshall H; Hajnal JV; Warren JE; Wise RJ; Larkman DJ
MAGMA; 2009 Jun; 22(3):187-200. PubMed ID: 19238472
[TBL] [Abstract][Full Text] [Related]
6. High-resolution gradient-recalled echo imaging at 9.4T using 16-channel parallel transmit simultaneous multislice spokes excitations with slice-by-slice flip angle homogenization.
Tse DHY; Wiggins CJ; Poser BA
Magn Reson Med; 2017 Sep; 78(3):1050-1058. PubMed ID: 27774641
[TBL] [Abstract][Full Text] [Related]
7. Simultaneous multislice imaging with slice-specific z-shim.
Finsterbusch J; Chu Y
Magn Reson Med; 2023 Aug; 90(2):633-642. PubMed ID: 37093986
[TBL] [Abstract][Full Text] [Related]
8. Real-time feedback optimization of z-shim gradient for automatic compensation of susceptibility-induced signal loss in EPI.
Tang YW; Huang TY
Neuroimage; 2011 Apr; 55(4):1587-92. PubMed ID: 21256230
[TBL] [Abstract][Full Text] [Related]
9. Application of an integrated radio-frequency/shim coil technology for signal recovery in fMRI.
Willey D; Darnell D; Song AW; Truong TK
Magn Reson Med; 2021 Dec; 86(6):3067-3081. PubMed ID: 34288086
[TBL] [Abstract][Full Text] [Related]
10. Automated slice-specific z-shimming for functional magnetic resonance imaging of the human spinal cord.
Kaptan M; Vannesjo SJ; Mildner T; Horn U; Hartley-Davies R; Oliva V; Brooks JCW; Weiskopf N; Finsterbusch J; Eippert F
Hum Brain Mapp; 2022 Dec; 43(18):5389-5407. PubMed ID: 35938527
[TBL] [Abstract][Full Text] [Related]
11. Feasibility of head-tilted brain scan to reduce susceptibility-induced signal loss in the prefrontal cortex in gradient echo-based imaging.
Yoo S; Song H; Kim SG; Shim WM; Lee SK
Neuroimage; 2020 Dec; 223():117265. PubMed ID: 32835820
[TBL] [Abstract][Full Text] [Related]
12. A 32-channel multi-coil setup optimized for human brain shimming at 9.4T.
Aghaeifar A; Zhou J; Heule R; Tabibian B; Schölkopf B; Jia F; Zaitsev M; Scheffler K
Magn Reson Med; 2020 Feb; 83(2):749-764. PubMed ID: 31483527
[TBL] [Abstract][Full Text] [Related]
13. Integrated RF/shim coil array for parallel reception and localized B0 shimming in the human brain.
Truong TK; Darnell D; Song AW
Neuroimage; 2014 Dec; 103():235-240. PubMed ID: 25270602
[TBL] [Abstract][Full Text] [Related]
14. Parallel imaging with asymmetric acceleration to reduce Gibbs artifacts and to increase signal-to-noise ratio of the gradient echo echo-planar imaging sequence for functional MRI.
Jung KJ; Zhao T
Magn Reson Med; 2012 Feb; 67(2):419-27. PubMed ID: 21713976
[TBL] [Abstract][Full Text] [Related]
15. Robust time-shifted spoke pulse design in the presence of large B0 variations with simultaneous reduction of through-plane dephasing, B1+ effects, and the specific absorption rate using parallel transmission.
Guérin B; Stockmann JP; Baboli M; Torrado-Carvajal A; Stenger AV; Wald LL
Magn Reson Med; 2016 Aug; 76(2):540-54. PubMed ID: 26444717
[TBL] [Abstract][Full Text] [Related]
16. Single, slice-specific z-shim gradient pulses improve T2*-weighted imaging of the spinal cord.
Finsterbusch J; Eippert F; Büchel C
Neuroimage; 2012 Feb; 59(3):2307-15. PubMed ID: 21979381
[TBL] [Abstract][Full Text] [Related]
17. Integrated parallel reception, excitation, and shimming (iPRES) with multiple shim loops per radio-frequency coil element for improved B
Darnell D; Truong TK; Song AW
Magn Reson Med; 2017 May; 77(5):2077-2086. PubMed ID: 27174387
[TBL] [Abstract][Full Text] [Related]
18. Single-shot dual-z-shimmed sensitivity-encoded spiral-in/out imaging for functional MRI with reduced susceptibility artifacts.
Truong TK; Song AW
Magn Reson Med; 2008 Jan; 59(1):221-7. PubMed ID: 18050341
[TBL] [Abstract][Full Text] [Related]
19. Single-shot interleaved z-shim EPI with optimized compensation for signal losses due to susceptibility-induced field inhomogeneity at 3 T.
Gu H; Feng H; Zhan W; Xu S; Silbersweig DA; Stern E; Yang Y
Neuroimage; 2002 Nov; 17(3):1358-64. PubMed ID: 12414275
[TBL] [Abstract][Full Text] [Related]
20. Breath-holding during the Calibration Scan Improves the Reproducibility of Parallel Transmission at 7T for Human Brain.
Harada T; Kudo K; Uwano I; Yamashita F; Kameda H; Matsuda T; Sasaki M; Shirato H
Magn Reson Med Sci; 2017 Jan; 16(1):23-31. PubMed ID: 27001392
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]