These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

222 related articles for article (PubMed ID: 25291753)

  • 1. Measurement of pupil center shift in refractive surgery candidates with caucasian eyes using infrared pupillometry.
    Mabed IS; Saad A; Guilbert E; Gatinel D
    J Refract Surg; 2014 Oct; 30(10):694-700. PubMed ID: 25291753
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Measurement of the spatial shift of the pupil center.
    Camellin M; Gambino F; Casaro S
    J Cataract Refract Surg; 2005 Sep; 31(9):1719-21. PubMed ID: 16246774
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Assessing Repeatability of Pupillometric Measurements in the Eyes of Refractive Surgery Candidates Using Infrared Pupillometer.
    Salah-Mabed I; Saad A; Gatinel D
    J Refract Surg; 2017 Aug; 33(8):552-557. PubMed ID: 28787521
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Digital pupillometry and centroid shift changes after cataract surgery.
    Kanellopoulos AJ; Asimellis G; Georgiadou S
    J Cataract Refract Surg; 2015 Feb; 41(2):408-14. PubMed ID: 25661135
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Mesopic pupil size in a refractive surgery population (13,959 eyes).
    Linke SJ; Baviera J; Munzer G; Fricke OH; Richard G; Katz T
    Optom Vis Sci; 2012 Aug; 89(8):1156-64. PubMed ID: 22773178
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Pupil center shift relative to the coaxially sighted corneal light reflex under natural and pharmacologically dilated conditions.
    Erdem U; Muftuoglu O; Gundogan FC; Sobaci G; Bayer A
    J Refract Surg; 2008 May; 24(5):530-8. PubMed ID: 18494347
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Distribution of Pupil Offset and Angle Kappa in a Refractive Surgery Preoperative Population of 750 Myopic, Emmetropic, and Hyperopic Eyes.
    Reinstein DZ; Archer TJ; Rowe EL; Gobbe M; Vida RS
    J Refract Surg; 2021 Jan; 37(1):49-58. PubMed ID: 33432995
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Pupil location under mesopic, photopic, and pharmacologically dilated conditions.
    Yang Y; Thompson K; Burns SA
    Invest Ophthalmol Vis Sci; 2002 Jul; 43(7):2508-12. PubMed ID: 12091457
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Use of a digital infrared pupillometer to assess patient suitability for refractive surgery.
    Rosen ES; Gore CL; Taylor D; Chitkara D; Howes F; Kowalewski E
    J Cataract Refract Surg; 2002 Aug; 28(8):1433-8. PubMed ID: 12160815
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Repeated pupil size measurements in refractive surgery candidates.
    Robl C; Sliesoraityte I; Hillenkamp J; Prahs P; Lohmann CP; Helbig H; Herrmann WA
    J Cataract Refract Surg; 2009 Dec; 35(12):2099-102. PubMed ID: 19969214
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Comparison of dynamic digital pupillometry and static measurements of pupil size in determining scotopic pupil size before refractive surgery.
    Wickremasinghe SS; Smith GT; Stevens JD
    J Cataract Refract Surg; 2005 Jun; 31(6):1171-6. PubMed ID: 16039493
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Changes in visual function under mesopic and photopic conditions after intrastromal corneal ring segment implantation for different stages of keratoconus.
    Carballo J; Puell MC; Cuiña R; Vázquez JM; Benitez-del-Castillo JM
    J Cataract Refract Surg; 2013 Mar; 39(3):393-402. PubMed ID: 23245506
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Changes in pupil size following panretinal retinal photocoagulation: conventional laser vs pattern scan laser (PASCAL).
    Yilmaz I; Perente I; Saracoglu B; Yazici AT; Taskapili M
    Eye (Lond); 2016 Oct; 30(10):1359-1364. PubMed ID: 27391936
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Comparison of two pupillometers in determining pupil size for refractive surgery.
    Bootsma S; Tahzib N; Eggink F; de Brabander J; Nuijts R
    Acta Ophthalmol Scand; 2007 May; 85(3):324-8. PubMed ID: 17488463
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Correlation of pupil sizes measured with a mesopic infrared pupillometer and a photopic topographer.
    Periman LM; Ambrosio R; Harrison DA; Wilson SE
    J Refract Surg; 2003; 19(5):555-9. PubMed ID: 14518744
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Q-optimized Algorithms: Theoretical Analysis of Factors Influencing Visual Quality After Myopic Corneal Refractive Surgery.
    Jiménez JR; Alarcón A; Anera RG; Jiménez Del Barco L
    J Refract Surg; 2016 Aug; 32(9):612-7. PubMed ID: 27598731
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Static and dynamic pupillary characteristics in high myopic eyes with two implantable collamer lenses.
    Zhu Y; He T; Zhu H; Chen J; Zhou J
    J Cataract Refract Surg; 2019 Jul; 45(7):946-951. PubMed ID: 31262483
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Reproducibility and normal values of static pupil diameters.
    Schröder S; Chashchina E; Janunts E; Cayless A; Langenbucher A
    Eur J Ophthalmol; 2018 Mar; 28(2):150-156. PubMed ID: 28885673
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Comparison of monocular and binocular infrared pupillometers under mesopic lighting conditions.
    Scheffel M; Kuehne C; Kohnen T
    J Cataract Refract Surg; 2010 Apr; 36(4):625-30. PubMed ID: 20362855
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Changes in pupil size and centroid shift in eyes with uncomplicated in-the-bag IOL implantation.
    Sobaci G; Erdem U; Uysal Y; Muftuoglu O
    J Refract Surg; 2007 Oct; 23(8):796-9. PubMed ID: 17985799
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 12.