495 related articles for article (PubMed ID: 25291951)
21. Accuracy and clinical implications of seven 25-hydroxyvitamin D methods compared with liquid chromatography-tandem mass spectrometry as a reference.
Roth HJ; Schmidt-Gayk H; Weber H; Niederau C
Ann Clin Biochem; 2008 Mar; 45(Pt 2):153-9. PubMed ID: 18325178
[TBL] [Abstract][Full Text] [Related]
22. Performance characteristics of the VIDAS® 25-OH Vitamin D Total assay - comparison with four immunoassays and two liquid chromatography-tandem mass spectrometry methods in a multicentric study.
Moreau E; Bächer S; Mery S; Le Goff C; Piga N; Vogeser M; Hausmann M; Cavalier E
Clin Chem Lab Med; 2016 Jan; 54(1):45-53. PubMed ID: 26124054
[TBL] [Abstract][Full Text] [Related]
23. Development and validation of an LC-MS/MS based method for quantification of 25 hydroxyvitamin D2 and 25 hydroxyvitamin D3 in human serum and plasma.
Zhang SW; Jian W; Sullivan S; Sankaran B; Edom RW; Weng N; Sharkey D
J Chromatogr B Analyt Technol Biomed Life Sci; 2014 Jun; 961():62-70. PubMed ID: 24861873
[TBL] [Abstract][Full Text] [Related]
24. Comparison of two 25-hydroxyvitamin D immunoassays to liquid chromatography-tandem mass spectrometry in assessing samples from the Chinese population.
Yun C; Chen J; Yang C; Li Y; Piao J; Yang X
Clin Chim Acta; 2015 Aug; 448():22-6. PubMed ID: 26093339
[TBL] [Abstract][Full Text] [Related]
25. Performance evaluation of Siemens ADVIA Centaur and Roche MODULAR Analytics E170 Total 25-OH Vitamin D assays.
Chen Y; Kinney L; Božović A; Smith H; Tarr H; Diamandis EP; LeBlanc A
Clin Biochem; 2012 Nov; 45(16-17):1485-90. PubMed ID: 22705028
[TBL] [Abstract][Full Text] [Related]
26. Variation in clinical vitamin D status by DiaSorin Liaison and LC-MS/MS in the presence of elevated 25-OH vitamin D2.
de Koning L; Al-Turkmani MR; Berg AH; Shkreta A; Law T; Kellogg MD
Clin Chim Acta; 2013 Jan; 415():54-8. PubMed ID: 22975531
[TBL] [Abstract][Full Text] [Related]
27. Methodological issues in assessing plasma 25-hydroxyvitamin D concentration in newborn infants.
Gallo S; Comeau K; Agellon S; Vanstone C; Sharma A; Jones G; L'abbé M; Khamessan A; Weiler H; Rodd C
Bone; 2014 Apr; 61():186-90. PubMed ID: 24473373
[TBL] [Abstract][Full Text] [Related]
28. Vitamin D Standardization Program (VDSP) intralaboratory study for the assessment of 25-hydroxyvitamin D assay variability and bias.
Wise SA; Camara JE; Sempos CT; Lukas P; Le Goff C; Peeters S; Burdette CQ; Nalin F; Hahm G; Durazo-Arvizu RA; Kuszak AJ; Merkel J; Cavalier É
J Steroid Biochem Mol Biol; 2021 Sep; 212():105917. PubMed ID: 34010687
[TBL] [Abstract][Full Text] [Related]
29. Assessment of low vitamin D among Saudi Arabians. Did we overshoot the runway?
Sadat-Ali M; Al-Elq AH; Al-Shaikh IH; Al-Turki HA; Al-Ali AK; Al-Othman AA
Saudi Med J; 2014 Oct; 35(10):1243-9. PubMed ID: 25316470
[TBL] [Abstract][Full Text] [Related]
30. Evaluation of two automated immunoassays for 25-OH vitamin D: comparison against LC-MS/MS.
Hsu SA; Soldo J; Gupta M
J Steroid Biochem Mol Biol; 2013 Jul; 136():139-45. PubMed ID: 23202147
[TBL] [Abstract][Full Text] [Related]
31. Clinical utility of simultaneous quantitation of 25-hydroxyvitamin D and 24,25-dihydroxyvitamin D by LC-MS/MS involving derivatization with DMEQ-TAD.
Kaufmann M; Gallagher JC; Peacock M; Schlingmann KP; Konrad M; DeLuca HF; Sigueiro R; Lopez B; Mourino A; Maestro M; St-Arnaud R; Finkelstein JS; Cooper DP; Jones G
J Clin Endocrinol Metab; 2014 Jul; 99(7):2567-74. PubMed ID: 24670084
[TBL] [Abstract][Full Text] [Related]
32. Comparison of four current 25-hydroxyvitamin D assays.
Moon HW; Cho JH; Hur M; Song J; Oh GY; Park CM; Yun YM; Kim JQ
Clin Biochem; 2012 Mar; 45(4-5):326-30. PubMed ID: 22244986
[TBL] [Abstract][Full Text] [Related]
33. The new Roche Vitamin D Total assay: fit for its purpose?
Emmen JM; Wielders JP; Boer AK; van den Ouweland JM; Vader HL
Clin Chem Lab Med; 2012 Nov; 50(11):1969-72. PubMed ID: 23113978
[TBL] [Abstract][Full Text] [Related]
34. 25-Hydroxyvitamin D Can Interfere With a Common Assay for 1,25-Dihydroxyvitamin D in Vitamin D Intoxication.
Hawkes CP; Schnellbacher S; Singh RJ; Levine MA
J Clin Endocrinol Metab; 2015 Aug; 100(8):2883-9. PubMed ID: 26120794
[TBL] [Abstract][Full Text] [Related]
35. Interlaboratory comparison of 25-hydroxyvitamin D assays: Vitamin D Standardization Program (VDSP) Intercomparison Study 2 - Part 1 liquid chromatography - tandem mass spectrometry (LC-MS/MS) assays - impact of 3-epi-25-hydroxyvitamin D
Wise SA; Camara JE; Burdette CQ; Hahm G; Nalin F; Kuszak AJ; Merkel J; Durazo-Arvizu RA; Williams EL; Hoofnagle AN; Ivison F; Fischer R; van den Ouweland JMW; Ho CS; Law EWK; Simard JN; Gonthier R; Holmquist B; Meadows S; Cox L; Robyak K; Creer MH; Fitzgerald R; Clarke MW; Breen N; Lukas P; Cavalier É; Sempos CT
Anal Bioanal Chem; 2022 Jan; 414(1):333-349. PubMed ID: 34432104
[TBL] [Abstract][Full Text] [Related]
36. Interlaboratory comparison of 25-hydroxyvitamin D assays: Vitamin D Standardization Program (VDSP) Intercomparison Study 2 - Part 2 ligand binding assays - impact of 25-hydroxyvitamin D
Wise SA; Camara JE; Burdette CQ; Hahm G; Nalin F; Kuszak AJ; Merkel J; Durazo-Arvizu RA; Williams EL; Popp C; Beckert C; Schultess J; Van Slooten G; Tourneur C; Pease C; Kaul R; Villarreal A; Batista MC; Pham H; Bennett A; Jansen E; Khan DA; Kilbane M; Twomey PJ; Freeman J; Parker N; Mushtaq S; Simpson C; Lukas P; Cavalier É; Sempos CT
Anal Bioanal Chem; 2022 Jan; 414(1):351-366. PubMed ID: 34435207
[TBL] [Abstract][Full Text] [Related]
37. Vitamin D Status in Children With Short Stature: Accurate Determination of Serum Vitamin D Components Using High-Performance Liquid Chromatography-Tandem Mass Spectrometry.
Xu B; Feng Y; Gan L; Zhang Y; Jiang W; Feng J; Yu L
Front Endocrinol (Lausanne); 2021; 12():707283. PubMed ID: 34721288
[TBL] [Abstract][Full Text] [Related]
38. Agreement of seven 25-hydroxy vitamin D₃ immunoassays and three high performance liquid chromatography methods with liquid chromatography tandem mass spectrometry.
Denimal D; Ducros V; Dupré T; Dousset B; Meunier C; Aho S; Guilland JC; Lemaire-Ewing S
Clin Chem Lab Med; 2014 Apr; 52(4):511-20. PubMed ID: 24152903
[TBL] [Abstract][Full Text] [Related]
39. Development and application of a LC-MS/MS assay for simultaneous analysis of 25-hydroxyvitamin-D and 3-epi-25-hydroxyvitamin-D metabolites in canine serum.
Hurst EA; Homer NZ; Denham SG; MacFarlane E; Campbell S; Boswinkel M; Mellanby RJ
J Steroid Biochem Mol Biol; 2020 May; 199():105598. PubMed ID: 31958632
[TBL] [Abstract][Full Text] [Related]
40. Analytical validation of the Roche 25-OH Vitamin D Total assay.
Knudsen CS; Nexo E; Højskov CS; Heickendorff L
Clin Chem Lab Med; 2012 Nov; 50(11):1965-8. PubMed ID: 23093282
[TBL] [Abstract][Full Text] [Related]
[Previous] [Next] [New Search]