These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

149 related articles for article (PubMed ID: 25293895)

  • 1. Error rate of multi-level rapid prototyping trajectories for pedicle screw placement in lumbar and sacral spine.
    Merc M; Drstvensek I; Vogrin M; Brajlih T; Friedrich T; Recnik G
    Chin J Traumatol; 2014; 17(5):261-6. PubMed ID: 25293895
    [TBL] [Abstract][Full Text] [Related]  

  • 2. A multi-level rapid prototyping drill guide template reduces the perforation risk of pedicle screw placement in the lumbar and sacral spine.
    Merc M; Drstvensek I; Vogrin M; Brajlih T; Recnik G
    Arch Orthop Trauma Surg; 2013 Jul; 133(7):893-9. PubMed ID: 23632782
    [TBL] [Abstract][Full Text] [Related]  

  • 3. A novel computer-assisted drill guide template for lumbar pedicle screw placement: a cadaveric and clinical study.
    Lu S; Xu YQ; Zhang YZ; Li YB; Xie L; Shi JH; Guo H; Chen GP; Chen YB
    Int J Med Robot; 2009 Jun; 5(2):184-91. PubMed ID: 19280584
    [TBL] [Abstract][Full Text] [Related]  

  • 4. A prospective multicenter registry on the accuracy of pedicle screw placement in the thoracic, lumbar, and sacral levels with the use of the O-arm imaging system and StealthStation Navigation.
    Van de Kelft E; Costa F; Van der Planken D; Schils F
    Spine (Phila Pa 1976); 2012 Dec; 37(25):E1580-7. PubMed ID: 23196967
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Development of a new technique for pedicle screw and Magerl screw insertion using a 3-dimensional image guide.
    Kawaguchi Y; Nakano M; Yasuda T; Seki S; Hori T; Kimura T
    Spine (Phila Pa 1976); 2012 Nov; 37(23):1983-8. PubMed ID: 22531473
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Clinical accuracy of computer-assisted two-dimensional fluoroscopy for the percutaneous placement of lumbosacral pedicle screws.
    Ravi B; Zahrai A; Rampersaud R
    Spine (Phila Pa 1976); 2011 Jan; 36(1):84-91. PubMed ID: 20595927
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Rapid prototyping drill guide template for lumbar pedicle screw placement.
    Lu S; Xu YQ; Zhang YZ; Li YB; Shi JH; Chen GP; Chen YB
    Chin J Traumatol; 2009 Jun; 12(3):177-80. PubMed ID: 19486561
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Lumbosacral pedicle screw placement using a fluoroscopic pedicle axis view and a cannulated tapping device.
    Yoshii T; Hirai T; Yamada T; Sumiya S; Mastumoto R; Kato T; Enomoto M; Inose H; Kawabata S; Shinomiya K; Okawa A
    J Orthop Surg Res; 2015 May; 10():79. PubMed ID: 26016564
    [TBL] [Abstract][Full Text] [Related]  

  • 9. A multi-level drill guide template improves the accuracy of pedicle screw placement in lumbar spine.
    Ge DW; Yang L; Chen X; Tang J; Chen HT; Li HJ; Sui T; Zhuang Y; Zheng SN; Cao XJ
    Eur Rev Med Pharmacol Sci; 2018 Jun; 22(12):3643-3648. PubMed ID: 29949135
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Safe and accurate midcervical pedicle screw insertion procedure with the patient-specific screw guide template system.
    Kaneyama S; Sugawara T; Sumi M
    Spine (Phila Pa 1976); 2015 Mar; 40(6):E341-8. PubMed ID: 25584951
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Three-dimensional image-guided placement of S2 alar screws to adjunct or salvage lumbosacral fixation.
    Nottmeier EW; Pirris SM; Balseiro S; Fenton D
    Spine J; 2010 Jul; 10(7):595-601. PubMed ID: 20434406
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Lumbar and sacral pedicle screw placement using a template does not improve the midterm pain and disability outcome in comparison with free-hand method.
    Merc M; Recnik G; Krajnc Z
    Eur J Orthop Surg Traumatol; 2017 Jul; 27(5):583-589. PubMed ID: 28101631
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Computed tomography assessment of lateral pedicle wall perforation by free-hand subaxial cervical pedicle screw placement.
    Wang Y; Xie J; Yang Z; Zhao Z; Zhang Y; Li T; Liu L
    Arch Orthop Trauma Surg; 2013 Jul; 133(7):901-9. PubMed ID: 23632781
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Accuracy of pedicle screw placement in the thoracic and lumbosacral spine using a conventional intraoperative fluoroscopy-guided technique: a national neurosurgical education and training center analysis of 1236 consecutive screws.
    Nevzati E; Marbacher S; Soleman J; Perrig WN; Diepers M; Khamis A; Fandino J
    World Neurosurg; 2014 Nov; 82(5):866-71.e1-2. PubMed ID: 24954252
    [TBL] [Abstract][Full Text] [Related]  

  • 15. A low invasiveness patient's specific template for spine surgery.
    Azimifar F; Hassani K; Saveh AH; Tabatabai Ghomshe F
    Proc Inst Mech Eng H; 2017 Feb; 231(2):143-148. PubMed ID: 28233504
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Safety and efficacy of pedicle screw placement using intraoperative computed tomography: consecutive series of 1148 pedicle screws.
    Bydon M; Xu R; Amin AG; Macki M; Kaloostian P; Sciubba DM; Wolinsky JP; Bydon A; Gokaslan ZL; Witham TF
    J Neurosurg Spine; 2014 Sep; 21(3):320-8. PubMed ID: 24926927
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Percutaneous "K-wireless" pedicle screw fixation technique: an evaluation of the initial experience of 100 screws with assessment of accuracy, radiation exposure, and procedure time.
    Spitz SM; Sandhu FA; Voyadzis JM
    J Neurosurg Spine; 2015 Apr; 22(4):422-31. PubMed ID: 25658468
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Cortical bone trajectory for lumbosacral fixation: penetrating S-1 endplate screw technique: technical note.
    Matsukawa K; Yato Y; Kato T; Imabayashi H; Asazuma T; Nemoto K
    J Neurosurg Spine; 2014 Aug; 21(2):203-9. PubMed ID: 24766288
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Feasibility and accuracy of computer-assisted individual drill guide template for minimally invasive lumbar pedicle screw placement trajectory.
    Wang H; Liu Y; Zhao Y; Song G; Liu J; Han J; Xiang L
    Injury; 2018 Mar; 49(3):644-648. PubMed ID: 29439802
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Stepwise methodology for plain radiographic assessment of pedicle screw placement: a comparison with computed tomography.
    Choma TJ; Denis F; Lonstein JE; Perra JH; Schwender JD; Garvey TA; Mullin WJ
    J Spinal Disord Tech; 2006 Dec; 19(8):547-53. PubMed ID: 17146296
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.