155 related articles for article (PubMed ID: 25295448)
1. The use of external event monitoring (web-loop) in the elucidation of symptoms associated with arrhythmias in a general population.
Epifanio HB; Katz M; Borges MA; Corrêa Ada G; Cintra FD; Grinberg RL; Ludovice AC; Valdigem BP; Silva NJ; Fenelon G
Einstein (Sao Paulo); 2014 Sep; 12(3):295-9. PubMed ID: 25295448
[TBL] [Abstract][Full Text] [Related]
2. Role of extended external loop recorders for the diagnosis of unexplained syncope, pre-syncope, and sustained palpitations.
Locati ET; Vecchi AM; Vargiu S; Cattafi G; Lunati M
Europace; 2014 Jun; 16(6):914-22. PubMed ID: 24158255
[TBL] [Abstract][Full Text] [Related]
3. External prolonged electrocardiogram monitoring in unexplained syncope and palpitations: results of the SYNARR-Flash study.
Locati ET; Moya A; Oliveira M; Tanner H; Willems R; Lunati M; Brignole M
Europace; 2016 Aug; 18(8):1265-72. PubMed ID: 26519025
[TBL] [Abstract][Full Text] [Related]
4. Efficacy of implantable loop recorders in establishing symptom-rhythm correlation in young patients with syncope and palpitations.
Rossano J; Bloemers B; Sreeram N; Balaji S; Shah MJ
Pediatrics; 2003 Sep; 112(3 Pt 1):e228-33. PubMed ID: 12949317
[TBL] [Abstract][Full Text] [Related]
5. Cardiac loop ECG recording: a new noninvasive diagnostic test in recurrent syncope.
Cumbee SR; Pryor RE; Linzer M
South Med J; 1990 Jan; 83(1):39-43. PubMed ID: 2300833
[TBL] [Abstract][Full Text] [Related]
6. Insertable loop recorder use for detection of intermittent arrhythmias.
Krahn AD; Klein GJ; Skanes AC; Yee R
Pacing Clin Electrophysiol; 2004 May; 27(5):657-64. PubMed ID: 15125724
[TBL] [Abstract][Full Text] [Related]
7. The utility of implantable loop recorders for diagnosing unexplained syncope in 100 consecutive patients: five-year, single-center experience.
Inamdar V; Mehta S; Juang G; Cohen T
J Invasive Cardiol; 2006 Jul; 18(7):313-5. PubMed ID: 16816436
[TBL] [Abstract][Full Text] [Related]
8. Detection of asymptomatic arrhythmias in unexplained syncope.
Krahn AD; Klein GJ; Yee R; Skanes AC
Am Heart J; 2004 Aug; 148(2):326-32. PubMed ID: 15309004
[TBL] [Abstract][Full Text] [Related]
9. Multi-centre randomised controlled trial of a smart phone-based event recorder alongside standard care versus standard care for patients presenting to the Emergency Department with palpitations and pre-syncope - the IPED (Investigation of Palpitations in the ED) study: study protocol for a randomised controlled trial.
Reed MJ; Grubb NR; Lang CC; O'Brien R; Simpson K; Padarenga M; Grant A; Tuck S
Trials; 2018 Dec; 19(1):711. PubMed ID: 30594256
[TBL] [Abstract][Full Text] [Related]
10. Incremental diagnostic yield of loop electrocardiographic recorders in unexplained syncope.
Linzer M; Pritchett EL; Pontinen M; McCarthy E; Divine GW
Am J Cardiol; 1990 Jul; 66(2):214-9. PubMed ID: 2371954
[TBL] [Abstract][Full Text] [Related]
11. Duration of Electrocardiographic Monitoring of Emergency Department Patients With Syncope.
Thiruganasambandamoorthy V; Rowe BH; Sivilotti MLA; McRae AD; Arcot K; Nemnom MJ; Huang L; Mukarram M; Krahn AD; Wells GA; Taljaard M
Circulation; 2019 Mar; 139(11):1396-1406. PubMed ID: 30661373
[TBL] [Abstract][Full Text] [Related]
12. Utility and cost of event recorders in the diagnosis of palpitations, presyncope, and syncope.
Fogel RI; Evans JJ; Prystowsky EN
Am J Cardiol; 1997 Jan; 79(2):207-8. PubMed ID: 9193028
[TBL] [Abstract][Full Text] [Related]
13. A retrospective study of the clinical experience of the implantable loop recorder in a paediatric setting.
Babikar A; Hynes B; Ward N; Oslizok P; Walsh K; Keane D
Int J Clin Pract; 2008 Oct; 62(10):1520-5. PubMed ID: 17764457
[TBL] [Abstract][Full Text] [Related]
14. [The usefullness of implantable loop recorders for evaluation of unexplained syncope and palpitations].
Kristjánsdóttir I; Reimarsdóttir G; Arnar DO
Laeknabladid; 2012 Sep; 98(9):465-8. PubMed ID: 22947628
[TBL] [Abstract][Full Text] [Related]
15. The diagnosis of cardiac arrhythmias: a prospective multi-center randomized study comparing mobile cardiac outpatient telemetry versus standard loop event monitoring.
Rothman SA; Laughlin JC; Seltzer J; Walia JS; Baman RI; Siouffi SY; Sangrigoli RM; Kowey PR
J Cardiovasc Electrophysiol; 2007 Mar; 18(3):241-7. PubMed ID: 17318994
[TBL] [Abstract][Full Text] [Related]
16. [Long term results of implantable loop recorder in patients with syncope: results of a French survey].
Amara W; Sileu N; Salih H; Sergent J; Monsel F
Ann Cardiol Angeiol (Paris); 2014 Nov; 63(5):327-30. PubMed ID: 25281994
[TBL] [Abstract][Full Text] [Related]
17. Usefulness of an Implantable Loop Recorder in Diagnosing Unexplained Syncope and Predictors for Pacemaker Implantation.
Lee SH; Kim TH; Oh YS; Oh S; Choi JI; Kim JB; Nah JC; Im SI; Kang KW; Han S; Kim JS
J Korean Med Sci; 2020 Jan; 35(2):e11. PubMed ID: 31920017
[TBL] [Abstract][Full Text] [Related]
18. Diagnostic yield of external electrocardiographic loop recorders in patients with recurrent syncope and negative tilt table test.
Schuchert A; Maas R; Kretzschmar C; Behrens G; Kratzmann I; Meinertz T
Pacing Clin Electrophysiol; 2003 Sep; 26(9):1837-40. PubMed ID: 12930497
[TBL] [Abstract][Full Text] [Related]
19. Suspected cardiac syncope in elderly patients: use of the 12-lead electrocardiogram to select patients for holter monitoring.
Manchanda S; Ehsanullah M
Gerontology; 2001; 47(4):195-7. PubMed ID: 11408724
[TBL] [Abstract][Full Text] [Related]
20. Use of an extended monitoring strategy in patients with problematic syncope. Reveal Investigators.
Krahn AD; Klein GJ; Yee R; Takle-Newhouse T; Norris C
Circulation; 1999 Jan; 99(3):406-10. PubMed ID: 9918528
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]