These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

207 related articles for article (PubMed ID: 25303795)

  • 41. First In Vivo Results of a Novel Pediatric Oxygenator with an Integrated Pulsatile Pump.
    Stang K; Borchardt R; Neumann B; Kurz J; Stoppelkamp S; Greiner TO; Fahrner C; Schenk M; Schlensak C; Schubert M; Lausberg H; Herold S; Schlanstein PC; Steinseifer U; Arens J; Wendel HP
    ASAIO J; 2015; 61(5):574-82. PubMed ID: 26098176
    [TBL] [Abstract][Full Text] [Related]  

  • 42. [Extracorporeal membrane oxygenation treatment of a neonate with severe low cardiac output syndrome following open heart surgery].
    Lin R; Tan LH; Zhang ZW; Sun MY; Du LZ
    Zhonghua Er Ke Za Zhi; 2008 Jan; 46(1):26-9. PubMed ID: 18353234
    [TBL] [Abstract][Full Text] [Related]  

  • 43. Hemolysis during cardiac extracorporeal membrane oxygenation: a case-control comparison of roller pumps and centrifugal pumps in a pediatric population.
    Byrnes J; McKamie W; Swearingen C; Prodhan P; Bhutta A; Jaquiss R; Imamura M; Fiser R
    ASAIO J; 2011; 57(5):456-61. PubMed ID: 21822124
    [TBL] [Abstract][Full Text] [Related]  

  • 44. Using a roller pump for establishing extra-corporal membrane oxygenation (ECMO) - technical considerations for times of crisis.
    Kaluza M; May B; Doenst T
    Perfusion; 2022 Apr; 37(3):229-234. PubMed ID: 33637027
    [TBL] [Abstract][Full Text] [Related]  

  • 45. Evaluation of Combined Extracorporeal Life Support and Continuous Renal Replacement Therapy on Hemodynamic Performance and Gaseous Microemboli Handling Ability in a Simulated Neonatal ECLS System.
    Shank KR; Profeta E; Wang S; O'Connor C; Kunselman AR; Woitas K; Myers JL; Ündar A
    Artif Organs; 2018 Apr; 42(4):365-376. PubMed ID: 28940550
    [TBL] [Abstract][Full Text] [Related]  

  • 46. Performance of polymethyl pentene oxygenators for neonatal extracorporeal membrane oxygenation: a comparison with silicone membrane oxygenators.
    Khoshbin E; Westrope C; Pooboni S; Machin D; Killer H; Peek GJ; Sosnowski AW; Firmin RK
    Perfusion; 2005 May; 20(3):129-34. PubMed ID: 16038383
    [TBL] [Abstract][Full Text] [Related]  

  • 47. A centrifugal pump driven tidal flow extracorporeal membrane oxygenation system tested with neonatal mock circulation.
    Trittenwein G; Kölbl R; Trittenwein H; Golej J; Burda G; Hermon M; Pollak A
    Artif Organs; 1999 Jun; 23(6):524-8. PubMed ID: 10392278
    [TBL] [Abstract][Full Text] [Related]  

  • 48. Gas exchange efficiency of an oxygenator with integrated pulsatile displacement blood pump for neonatal patients.
    Schlanstein PC; Borchardt R; Mager I; Schmitz-Rode T; Steinseifer U; Arens J
    Int J Artif Organs; 2014 Jan; 37(1):88-92. PubMed ID: 24634337
    [TBL] [Abstract][Full Text] [Related]  

  • 49. Blood Pumps for Extracorporeal Membrane Oxygenation: Platelet Activation During Different Operating Conditions.
    Fiusco F; Broman LM; Prahl Wittberg L
    ASAIO J; 2022 Jan; 68(1):79-86. PubMed ID: 34074850
    [TBL] [Abstract][Full Text] [Related]  

  • 50. Evaluation of the Novel Centrifugal Pump, CAPIOX SL, in Chronic Large Animal Experiments.
    Iizuka K; Katagiri N; Takewa Y; Tsukiya T; Mizuno T; Itamochi Y; Kumano K; Tatsumi E
    Artif Organs; 2018 Aug; 42(8):835-841. PubMed ID: 29435994
    [TBL] [Abstract][Full Text] [Related]  

  • 51. Hemolysis at low blood flow rates: in-vitro and in-silico evaluation of a centrifugal blood pump.
    Schöps M; Groß-Hardt SH; Schmitz-Rode T; Steinseifer U; Brodie D; Clauser JC; Karagiannidis C
    J Transl Med; 2021 Jan; 19(1):2. PubMed ID: 33402176
    [TBL] [Abstract][Full Text] [Related]  

  • 52. Computational fluid dynamics-based design and in vitro characterization of a novel pediatric pump-lung.
    Han D; Zhang J; He G; Griffith BP; Wu ZJ
    Artif Organs; 2024 Feb; 48(2):130-140. PubMed ID: 37860931
    [TBL] [Abstract][Full Text] [Related]  

  • 53. Effect of Normobaric versus Hypobaric Oxygenation on Gaseous Microemboli Removal in a Diffusion Membrane Oxygenator: An In Vitro Comparison.
    Schuldes M; Riley JB; Francis SG; Clingan S
    J Extra Corpor Technol; 2016 Sep; 48(3):129-136. PubMed ID: 27729706
    [TBL] [Abstract][Full Text] [Related]  

  • 54. Experimental evaluation of a heparin coated ECMO system simplified with a centrifugal pump.
    Matsuwaka R; Matsuda H; Kaneko M; Miyamoto Y; Sakagoshi N; Kuratani T; Chang JC; Kawashima Y; Hagiwara K; Fukazawa H
    ASAIO Trans; 1990; 36(3):M473-5. PubMed ID: 2123638
    [TBL] [Abstract][Full Text] [Related]  

  • 55. Influence of different oxygenator types on changing frequency, infection incidence, and mortality in ARDS patients on veno-venous ECMO.
    Robak O; Lakatos PK; Bojic A; Hermann A; Laczika KF; Chiari A; Hiesmayr JM; Staudinger T; Locker GJ
    Int J Artif Organs; 2014 Nov; 37(11):839-46. PubMed ID: 25362902
    [TBL] [Abstract][Full Text] [Related]  

  • 56. Increased hemolysis from saline pre-washing RBCs or centrifugal pumps in neonatal ECMO.
    Masalunga C; Cruz M; Porter B; Roseff S; Chui B; Mainali E
    J Perinatol; 2007 Jun; 27(6):380-4. PubMed ID: 17443201
    [TBL] [Abstract][Full Text] [Related]  

  • 57. Hemolytic characteristics of three commercially available centrifugal blood pumps.
    Lawson DS; Ing R; Cheifetz IM; Walczak R; Craig D; Schulman S; Kern F; Shearer IR; Lodge A; Jaggers J
    Pediatr Crit Care Med; 2005 Sep; 6(5):573-7. PubMed ID: 16148820
    [TBL] [Abstract][Full Text] [Related]  

  • 58. Building a Better Neonatal Extracorporeal Life Support Circuit: Comparison of Hemodynamic Performance and Gaseous Microemboli Handling in Different Pump and Oxygenator Technologies.
    Glass K; Trivedi P; Wang S; Woitas K; Kunselman AR; Ündar A
    Artif Organs; 2017 Apr; 41(4):392-400. PubMed ID: 28397410
    [TBL] [Abstract][Full Text] [Related]  

  • 59. Effect of blood flow on platelets, leukocytes, and extracellular vesicles in thrombosis of simulated neonatal extracorporeal circulation.
    Meyer AD; Rishmawi AR; Kamucheka R; Lafleur C; Batchinsky AI; Mackman N; Cap AP
    J Thromb Haemost; 2020 Feb; 18(2):399-410. PubMed ID: 31628728
    [TBL] [Abstract][Full Text] [Related]  

  • 60. Cardiopulmonary bypass with a surface-heparinized extracorporeal perfusion system.
    Palatianos GM; Dewanjee MK; Kapadvanjwala M; Novak S; Sfakianakis GN; Kaiser GA
    ASAIO Trans; 1990; 36(3):M476-9. PubMed ID: 2252729
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 11.