These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

609 related articles for article (PubMed ID: 25303970)

  • 1. Arterial pressure waveform analysis versus thermodilution cardiac output measurement during open abdominal aortic aneurysm repair: a prospective observational study.
    Montenij LJ; Buhre WF; de Jong SA; Harms JH; van Herwaarden JA; Kruitwagen CL; de Waal EE
    Eur J Anaesthesiol; 2015 Jan; 32(1):13-9. PubMed ID: 25303970
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Accuracy, Precision, and Trending Ability of Uncalibrated Arterial Pressure Waveform Analysis of Cardiac Output in Patients With Impaired Left Ventricular Function: A Prospective, Observational Study.
    Montenij LJ; Sonneveld JP; Nierich AP; Buhre WF; De Waal EE
    J Cardiothorac Vasc Anesth; 2016 Jan; 30(1):115-21. PubMed ID: 26520028
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Calibrated versus uncalibrated arterial pressure waveform analysis in monitoring cardiac output with transpulmonary thermodilution in patients with severe sepsis and septic shock: an observational study.
    Slagt C; Helmi M; Malagon I; Groeneveld AB
    Eur J Anaesthesiol; 2015 Jan; 32(1):5-12. PubMed ID: 25387298
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Uncalibrated radial and femoral arterial pressure waveform analysis for continuous cardiac output measurement: an evaluation in cardiac surgery patients.
    Hofer CK; Button D; Weibel L; Genoni M; Zollinger A
    J Cardiothorac Vasc Anesth; 2010 Apr; 24(2):257-64. PubMed ID: 19700349
    [TBL] [Abstract][Full Text] [Related]  

  • 5. The Ability of esCCO and ECOM Monitors to Measure Trends in Cardiac Output During Alveolar Recruitment Maneuver After Cardiac Surgery: A Comparison with the Pulmonary Thermodilution Method.
    Thonnerieux M; Alexander B; Binet C; Obadia JF; Bastien O; Desebbe O
    Anesth Analg; 2015 Aug; 121(2):383-91. PubMed ID: 25902321
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Semi-invasive monitoring of cardiac output by a new device using arterial pressure waveform analysis: a comparison with intermittent pulmonary artery thermodilution in patients undergoing cardiac surgery.
    Mayer J; Boldt J; Schöllhorn T; Röhm KD; Mengistu AM; Suttner S
    Br J Anaesth; 2007 Feb; 98(2):176-82. PubMed ID: 17218375
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Cardiac Output Measurements Based on the Pulse Wave Transit Time and Thoracic Impedance Exhibit Limited Agreement With Thermodilution Method During Orthotopic Liver Transplantation.
    Magliocca A; Rezoagli E; Anderson TA; Burns SM; Ichinose F; Chitilian HV
    Anesth Analg; 2018 Jan; 126(1):85-92. PubMed ID: 28598912
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Validity of an arterial pressure waveform analysis device: does the puncture site play a role in the agreement with intermittent pulmonary artery catheter thermodilution measurements?
    Schramm S; Albrecht E; Frascarolo P; Chassot PG; Spahn DR
    J Cardiothorac Vasc Anesth; 2010 Apr; 24(2):250-6. PubMed ID: 19700347
    [TBL] [Abstract][Full Text] [Related]  

  • 9. [Clinical evaluation of intraoperative cardiac output measurement by a new arterial pressure waveform analysis method( FloTrac/Vigileo) in open heart surgery].
    Furukawa H; Ohkado A; Nagashima M; Ohsawa H; Ichikawa S
    Kyobu Geka; 2013 Aug; 66(9):775-83. PubMed ID: 23917227
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Reliability of cardiac output measurements using LiDCOrapid™ and FloTrac/Vigileo™ across broad ranges of cardiac output values.
    Asamoto M; Orii R; Otsuji M; Bougaki M; Imai Y; Yamada Y
    J Clin Monit Comput; 2017 Aug; 31(4):709-716. PubMed ID: 27300325
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Agreement in hemodynamic monitoring during orthotopic liver transplantation: a comparison of FloTrac/Vigileo at two monitoring sites with pulmonary artery catheter thermodilution.
    Lee M; Weinberg L; Pearce B; Scurrah N; Story DA; Pillai P; McCall PR; P McNicol L; Peyton PJ
    J Clin Monit Comput; 2017 Apr; 31(2):343-351. PubMed ID: 26884378
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Cardiac output measurement by bioimpedance and noninvasive pulse contour analysis compared with the continuous pulmonary artery thermodilution technique.
    Maass SW; Roekaerts PM; Lancé MD
    J Cardiothorac Vasc Anesth; 2014 Jun; 28(3):534-9. PubMed ID: 24746334
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Cardiac output measured by a new arterial pressure waveform analysis method without calibration compared with thermodilution after cardiac surgery.
    Breukers RM; Sepehrkhouy S; Spiegelenberg SR; Groeneveld AB
    J Cardiothorac Vasc Anesth; 2007 Oct; 21(5):632-5. PubMed ID: 17905265
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Ability of the third-generation FloTrac/Vigileo software to track changes in cardiac output in cardiac surgery patients: a polar plot approach.
    Desebbe O; Henaine R; Keller G; Koffel C; Garcia H; Rosamel P; Obadia JF; Bastien O; Lehot JJ; Haftek M; Critchley LA
    J Cardiothorac Vasc Anesth; 2013 Dec; 27(6):1122-7. PubMed ID: 24011911
    [TBL] [Abstract][Full Text] [Related]  

  • 15. The value of arterial pressure waveform cardiac output measurements in the radial and femoral artery in major cardiac surgery patients.
    van Drumpt A; van Bommel J; Hoeks S; Grüne F; Wolvetang T; Bekkers J; Ter Horst M
    BMC Anesthesiol; 2017 Mar; 17(1):42. PubMed ID: 28288587
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Evaluation of the Fourth-Generation FloTrac/Vigileo System in Comparison With the Intermittent Bolus Thermodilution Method in Patients Undergoing Cardiac Surgery.
    Kusaka Y; Ohchi F; Minami T
    J Cardiothorac Vasc Anesth; 2019 Apr; 33(4):953-960. PubMed ID: 30077561
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Improved Performance of the Fourth-Generation FloTrac/Vigileo System for Tracking Cardiac Output Changes.
    Suehiro K; Tanaka K; Mikawa M; Uchihara Y; Matsuyama T; Matsuura T; Funao T; Yamada T; Mori T; Nishikawa K
    J Cardiothorac Vasc Anesth; 2015; 29(3):656-62. PubMed ID: 25440654
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Cardiac output measurement in patients undergoing liver transplantation: pulmonary artery catheter versus uncalibrated arterial pressure waveform analysis.
    Biais M; Nouette-Gaulain K; Cottenceau V; Vallet A; Cochard JF; Revel P; Sztark F
    Anesth Analg; 2008 May; 106(5):1480-6, table of contents. PubMed ID: 18420863
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Comparison of an advanced minimally invasive cardiac output monitoring with a continuous invasive cardiac output monitoring during lung transplantation.
    Tomasi R; Prueckner S; Czerner S; Schramm R; Preissler G; Zwißler B; von Dossow-Hanfstingl V
    J Clin Monit Comput; 2016 Aug; 30(4):475-80. PubMed ID: 26223864
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Comparison of accuracy of two uncalibrated pulse contour cardiac output monitors in off-pump coronary artery bypass surgery patients using pulmonary artery catheter-thermodilution as a reference.
    Mukkamala R; Kohl BA; Mahajan A
    BMC Anesthesiol; 2021 Jul; 21(1):189. PubMed ID: 34246222
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 31.