These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

374 related articles for article (PubMed ID: 25308061)

  • 1. Risk factors for technical failure of endoscopic double self-expandable metallic stent placement by partial stent-in-stent method.
    Kawakubo K; Kawakami H; Toyokawa Y; Otani K; Kuwatani M; Abe Y; Kawahata S; Kubo K; Kubota Y; Sakamoto N
    J Hepatobiliary Pancreat Sci; 2015 Jan; 22(1):79-85. PubMed ID: 25308061
    [TBL] [Abstract][Full Text] [Related]  

  • 2. High single-session success rate of endoscopic bilateral stent-in-stent placement with modified large cell Niti-S stents for malignant hilar biliary obstruction.
    Kogure H; Isayama H; Nakai Y; Tsujino T; Matsubara S; Yashima Y; Ito Y; Hamada T; Takahara N; Miyabayashi K; Mizuno S; Mohri D; Kawakubo K; Sasaki T; Yamamoto N; Hirano K; Sasahira N; Tada M; Koike K
    Dig Endosc; 2014 Jan; 26(1):93-9. PubMed ID: 23517109
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Reintervention for stent occlusion after bilateral self-expandable metallic stent placement for malignant hilar biliary obstruction.
    Inoue T; Naitoh I; Okumura F; Ozeki T; Anbe K; Iwasaki H; Nishie H; Mizushima T; Sano H; Nakazawa T; Yoneda M; Joh T
    Dig Endosc; 2016 Nov; 28(7):731-737. PubMed ID: 27088888
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Single-step simultaneous side-by-side placement of a self-expandable metallic stent with a 6-Fr delivery system for unresectable malignant hilar biliary obstruction: a feasibility study.
    Kawakubo K; Kawakami H; Kuwatani M; Kudo T; Abe Y; Kawahata S; Kubo K; Kubota Y; Sakamoto N
    J Hepatobiliary Pancreat Sci; 2015 Feb; 22(2):151-5. PubMed ID: 25345586
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Predictive factors for the failure of endoscopic stent-in-stent self-expandable metallic stent placement to treat malignant hilar biliary obstruction.
    Sugimoto M; Takagi T; Suzuki R; Konno N; Asama H; Watanabe K; Nakamura J; Kikuchi H; Waragai Y; Takasumi M; Sato Y; Hikichi T; Ohira H
    World J Gastroenterol; 2017 Sep; 23(34):6273-6280. PubMed ID: 28974893
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Revision of bilateral self-expandable metallic stents placed using the stent-in-stent technique for malignant hilar biliary obstruction.
    Son JH; Lee HS; Lee SH; Bang S; Kang J; Paik WH; Ryu JK; Kim YT
    Hepatobiliary Pancreat Dis Int; 2018 Oct; 17(5):437-442. PubMed ID: 30082195
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Clinical Outcomes of Bilateral Stent-in-Stent Placement Using Self-Expandable Metallic Stent for High-Grade Malignant Hilar Biliary Obstruction.
    Heo JY; Lee HS; Son JH; Lee SH; Bang S
    Yonsei Med J; 2018 Sep; 59(7):827-833. PubMed ID: 30091315
    [TBL] [Abstract][Full Text] [Related]  

  • 8. The evaluation of bilateral stenting using braided or laser-cut self-expandable metallic stent for malignant hilar biliary obstruction.
    Okuno M; Iwata K; Mukai T; Ohashi Y; Iwata S; Iwasa Y; Yoshida K; Maruta A; Tezuka R; Ichikawa H; Mita N; Uemura S; Iwashita T; Tomita E; Shimizu M
    Surg Endosc; 2023 Nov; 37(11):8489-8497. PubMed ID: 37759143
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Usefulness of a newly designed plastic stent for endoscopic re-intervention in patients with malignant hilar biliary obstruction.
    Tomoda T; Kato H; Kawamoto H; Muro S; Akimoto Y; Uchida D; Matsumoto K; Horiguchi S; Tsutsumi K; Okada H
    Endoscopy; 2017 Nov; 49(11):1087-1091. PubMed ID: 28753695
    [No Abstract]   [Full Text] [Related]  

  • 10. Combined side-by-side and stent-in-stent method for triple metal stenting in patients with malignant hilar biliary obstruction.
    Inoue T; Ibusuki M; Kitano R; Kobayashi Y; Ohashi T; Nakade Y; Sumida Y; Ito K; Nakao H; Yoneda M
    Dig Endosc; 2019 Nov; 31(6):698-705. PubMed ID: 31120163
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Combined endoscopic stent-in-stent placement for malignant biliary and duodenal obstruction by using a new duodenal metal stent (with videos).
    Moon JH; Choi HJ; Ko BM; Koo HC; Hong SJ; Cheon YK; Cho YD; Lee MS; Shim CS
    Gastrointest Endosc; 2009 Oct; 70(4):772-7. PubMed ID: 19595319
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Expandable metal stents for endoscopic bilateral stent-within-stent placement for malignant hilar biliary obstruction.
    Chahal P; Baron TH
    Gastrointest Endosc; 2010 Jan; 71(1):195-9. PubMed ID: 19945101
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Covered duodenal self-expandable metal stents prolong biliary stent patency in double stenting: The largest series of bilioduodenal obstruction.
    Hori Y; Naitoh I; Hayashi K; Kondo H; Yoshida M; Shimizu S; Hirano A; Okumura F; Ando T; Jinno N; Takada H; Togawa S; Joh T
    J Gastroenterol Hepatol; 2018 Mar; 33(3):696-703. PubMed ID: 28902972
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Evaluation of endoscopic reintervention for self-expandable metallic stent obstruction after stent-in-stent placement for malignant hilar biliary obstruction.
    Okuno M; Mukai T; Iwashita T; Ichikawa H; Iwasa Y; Mita N; Yoshida K; Iwata K; Tomita E; Shimizu M
    J Hepatobiliary Pancreat Sci; 2019 Jun; 26(6):211-218. PubMed ID: 30950234
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Risk factors for recurrent biliary obstruction following placement of self-expandable metallic stents in patients with malignant perihilar biliary stricture.
    Miura S; Kanno A; Masamune A; Hamada S; Hongou S; Yoshida N; Nakano E; Takikawa T; Kume K; Kikuta K; Hirota M; Yoshida H; Katayose Y; Unno M; Shimosegawa T
    Endoscopy; 2016 Jun; 48(6):536-45. PubMed ID: 26987646
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Evaluating optimal bilateral biliary stenting in endoscopic reintervention after initial plastic stent dysfunction for unresectable malignant hilar biliary obstruction: Retrospective cross-sectional study.
    Okuno M; Iwata K; Iwashita T; Mukai T; Shimojo K; Ohashi Y; Iwasa Y; Senju A; Iwata S; Tezuka R; Ichikawa H; Mita N; Uemura S; Yoshida K; Maruta A; Tomita E; Yasuda I; Shimizu M
    Dig Endosc; 2024 Oct; 36(10):1153-1163. PubMed ID: 38486465
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Use of endoscopic ultrasound-guided biliary drainage as a rescue of re-intervention after the placement of multiple metallic stents for malignant hilar biliary obstruction.
    Kitamura H; Hijioka S; Nagashio Y; Sugawara S; Nara S; Sone M; Esaki M; Arai Y; Okusaka T; Nakajima A
    J Hepatobiliary Pancreat Sci; 2022 Mar; 29(3):404-414. PubMed ID: 34661973
    [TBL] [Abstract][Full Text] [Related]  

  • 18. 8-mm versus 10-mm diameter self-expandable metallic stent in bilateral endoscopic stent-in-stent deployment for malignant hilar biliary obstruction.
    Naitoh I; Nakazawa T; Ban T; Okumura F; Hirano A; Takada H; Togawa S; Hayashi K; Miyabe K; Shimizu S; Kondo H; Nishi Y; Yoshida M; Yamashita H; Umemura S; Hori Y; Kato A; Sano H; Joh T
    J Hepatobiliary Pancreat Sci; 2015 May; 22(5):396-401. PubMed ID: 25611012
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Placement of a Newly Designed Y-Configured Bilateral Self-Expanding Metallic Stent for Hilar Biliary Obstruction: A Pilot Study.
    Jiao D; Huang K; Zhu M; Wu G; Ren J; Wang Y; Han X
    Dig Dis Sci; 2017 Jan; 62(1):253-263. PubMed ID: 27586033
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Topic controversies in the endoscopic management of malignant hilar strictures using metal stent: side-by-side versus stent-in-stent techniques.
    Moon JH; Rerknimitr R; Kogure H; Nakai Y; Isayama H
    J Hepatobiliary Pancreat Sci; 2015 Sep; 22(9):650-6. PubMed ID: 26136361
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 19.