373 related articles for article (PubMed ID: 25308061)
1. Risk factors for technical failure of endoscopic double self-expandable metallic stent placement by partial stent-in-stent method.
Kawakubo K; Kawakami H; Toyokawa Y; Otani K; Kuwatani M; Abe Y; Kawahata S; Kubo K; Kubota Y; Sakamoto N
J Hepatobiliary Pancreat Sci; 2015 Jan; 22(1):79-85. PubMed ID: 25308061
[TBL] [Abstract][Full Text] [Related]
2. High single-session success rate of endoscopic bilateral stent-in-stent placement with modified large cell Niti-S stents for malignant hilar biliary obstruction.
Kogure H; Isayama H; Nakai Y; Tsujino T; Matsubara S; Yashima Y; Ito Y; Hamada T; Takahara N; Miyabayashi K; Mizuno S; Mohri D; Kawakubo K; Sasaki T; Yamamoto N; Hirano K; Sasahira N; Tada M; Koike K
Dig Endosc; 2014 Jan; 26(1):93-9. PubMed ID: 23517109
[TBL] [Abstract][Full Text] [Related]
3. Reintervention for stent occlusion after bilateral self-expandable metallic stent placement for malignant hilar biliary obstruction.
Inoue T; Naitoh I; Okumura F; Ozeki T; Anbe K; Iwasaki H; Nishie H; Mizushima T; Sano H; Nakazawa T; Yoneda M; Joh T
Dig Endosc; 2016 Nov; 28(7):731-737. PubMed ID: 27088888
[TBL] [Abstract][Full Text] [Related]
4. Single-step simultaneous side-by-side placement of a self-expandable metallic stent with a 6-Fr delivery system for unresectable malignant hilar biliary obstruction: a feasibility study.
Kawakubo K; Kawakami H; Kuwatani M; Kudo T; Abe Y; Kawahata S; Kubo K; Kubota Y; Sakamoto N
J Hepatobiliary Pancreat Sci; 2015 Feb; 22(2):151-5. PubMed ID: 25345586
[TBL] [Abstract][Full Text] [Related]
5. Predictive factors for the failure of endoscopic stent-in-stent self-expandable metallic stent placement to treat malignant hilar biliary obstruction.
Sugimoto M; Takagi T; Suzuki R; Konno N; Asama H; Watanabe K; Nakamura J; Kikuchi H; Waragai Y; Takasumi M; Sato Y; Hikichi T; Ohira H
World J Gastroenterol; 2017 Sep; 23(34):6273-6280. PubMed ID: 28974893
[TBL] [Abstract][Full Text] [Related]
6. Revision of bilateral self-expandable metallic stents placed using the stent-in-stent technique for malignant hilar biliary obstruction.
Son JH; Lee HS; Lee SH; Bang S; Kang J; Paik WH; Ryu JK; Kim YT
Hepatobiliary Pancreat Dis Int; 2018 Oct; 17(5):437-442. PubMed ID: 30082195
[TBL] [Abstract][Full Text] [Related]
7. Clinical Outcomes of Bilateral Stent-in-Stent Placement Using Self-Expandable Metallic Stent for High-Grade Malignant Hilar Biliary Obstruction.
Heo JY; Lee HS; Son JH; Lee SH; Bang S
Yonsei Med J; 2018 Sep; 59(7):827-833. PubMed ID: 30091315
[TBL] [Abstract][Full Text] [Related]
8. The evaluation of bilateral stenting using braided or laser-cut self-expandable metallic stent for malignant hilar biliary obstruction.
Okuno M; Iwata K; Mukai T; Ohashi Y; Iwata S; Iwasa Y; Yoshida K; Maruta A; Tezuka R; Ichikawa H; Mita N; Uemura S; Iwashita T; Tomita E; Shimizu M
Surg Endosc; 2023 Nov; 37(11):8489-8497. PubMed ID: 37759143
[TBL] [Abstract][Full Text] [Related]
9. Usefulness of a newly designed plastic stent for endoscopic re-intervention in patients with malignant hilar biliary obstruction.
Tomoda T; Kato H; Kawamoto H; Muro S; Akimoto Y; Uchida D; Matsumoto K; Horiguchi S; Tsutsumi K; Okada H
Endoscopy; 2017 Nov; 49(11):1087-1091. PubMed ID: 28753695
[No Abstract] [Full Text] [Related]
10. Combined side-by-side and stent-in-stent method for triple metal stenting in patients with malignant hilar biliary obstruction.
Inoue T; Ibusuki M; Kitano R; Kobayashi Y; Ohashi T; Nakade Y; Sumida Y; Ito K; Nakao H; Yoneda M
Dig Endosc; 2019 Nov; 31(6):698-705. PubMed ID: 31120163
[TBL] [Abstract][Full Text] [Related]
11. Combined endoscopic stent-in-stent placement for malignant biliary and duodenal obstruction by using a new duodenal metal stent (with videos).
Moon JH; Choi HJ; Ko BM; Koo HC; Hong SJ; Cheon YK; Cho YD; Lee MS; Shim CS
Gastrointest Endosc; 2009 Oct; 70(4):772-7. PubMed ID: 19595319
[TBL] [Abstract][Full Text] [Related]
12. Expandable metal stents for endoscopic bilateral stent-within-stent placement for malignant hilar biliary obstruction.
Chahal P; Baron TH
Gastrointest Endosc; 2010 Jan; 71(1):195-9. PubMed ID: 19945101
[TBL] [Abstract][Full Text] [Related]
13. Covered duodenal self-expandable metal stents prolong biliary stent patency in double stenting: The largest series of bilioduodenal obstruction.
Hori Y; Naitoh I; Hayashi K; Kondo H; Yoshida M; Shimizu S; Hirano A; Okumura F; Ando T; Jinno N; Takada H; Togawa S; Joh T
J Gastroenterol Hepatol; 2018 Mar; 33(3):696-703. PubMed ID: 28902972
[TBL] [Abstract][Full Text] [Related]
14. Evaluation of endoscopic reintervention for self-expandable metallic stent obstruction after stent-in-stent placement for malignant hilar biliary obstruction.
Okuno M; Mukai T; Iwashita T; Ichikawa H; Iwasa Y; Mita N; Yoshida K; Iwata K; Tomita E; Shimizu M
J Hepatobiliary Pancreat Sci; 2019 Jun; 26(6):211-218. PubMed ID: 30950234
[TBL] [Abstract][Full Text] [Related]
15. Risk factors for recurrent biliary obstruction following placement of self-expandable metallic stents in patients with malignant perihilar biliary stricture.
Miura S; Kanno A; Masamune A; Hamada S; Hongou S; Yoshida N; Nakano E; Takikawa T; Kume K; Kikuta K; Hirota M; Yoshida H; Katayose Y; Unno M; Shimosegawa T
Endoscopy; 2016 Jun; 48(6):536-45. PubMed ID: 26987646
[TBL] [Abstract][Full Text] [Related]
16. Use of endoscopic ultrasound-guided biliary drainage as a rescue of re-intervention after the placement of multiple metallic stents for malignant hilar biliary obstruction.
Kitamura H; Hijioka S; Nagashio Y; Sugawara S; Nara S; Sone M; Esaki M; Arai Y; Okusaka T; Nakajima A
J Hepatobiliary Pancreat Sci; 2022 Mar; 29(3):404-414. PubMed ID: 34661973
[TBL] [Abstract][Full Text] [Related]
17. 8-mm versus 10-mm diameter self-expandable metallic stent in bilateral endoscopic stent-in-stent deployment for malignant hilar biliary obstruction.
Naitoh I; Nakazawa T; Ban T; Okumura F; Hirano A; Takada H; Togawa S; Hayashi K; Miyabe K; Shimizu S; Kondo H; Nishi Y; Yoshida M; Yamashita H; Umemura S; Hori Y; Kato A; Sano H; Joh T
J Hepatobiliary Pancreat Sci; 2015 May; 22(5):396-401. PubMed ID: 25611012
[TBL] [Abstract][Full Text] [Related]
18. Placement of a Newly Designed Y-Configured Bilateral Self-Expanding Metallic Stent for Hilar Biliary Obstruction: A Pilot Study.
Jiao D; Huang K; Zhu M; Wu G; Ren J; Wang Y; Han X
Dig Dis Sci; 2017 Jan; 62(1):253-263. PubMed ID: 27586033
[TBL] [Abstract][Full Text] [Related]
19. Topic controversies in the endoscopic management of malignant hilar strictures using metal stent: side-by-side versus stent-in-stent techniques.
Moon JH; Rerknimitr R; Kogure H; Nakai Y; Isayama H
J Hepatobiliary Pancreat Sci; 2015 Sep; 22(9):650-6. PubMed ID: 26136361
[TBL] [Abstract][Full Text] [Related]
20. Endoscopic biliary stent insertion through specialized duodenal stent for combined malignant biliary and duodenal obstruction facilitated by stent or PTBD guidance.
Lee JJ; Hyun JJ; Choe JW; Lee DW; Kim SY; Jung SW; Jung YK; Koo JS; Yim HJ; Lee SW
Scand J Gastroenterol; 2017 Nov; 52(11):1258-1262. PubMed ID: 28685637
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]