These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

137 related articles for article (PubMed ID: 25308107)

  • 1. Description of a new non-injectable connector to reduce the complications of arterial blood sampling.
    Mariyaselvam MZ; Heij RE; Laba D; Richardson JA; Hodges EJ; Maduakor CA; Carter JJ; Young PJ
    Anaesthesia; 2015 Jan; 70(1):51-5. PubMed ID: 25308107
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Disinfection of needleless catheter connectors and access ports with alcohol may not prevent microbial entry: the promise of a novel antiseptic-barrier cap.
    Menyhay SZ; Maki DG
    Infect Control Hosp Epidemiol; 2006 Jan; 27(1):23-7. PubMed ID: 16418982
    [TBL] [Abstract][Full Text] [Related]  

  • 3. The coated antiseptic tip (CAT) syringe.
    Mariyaselvam M; Hodges E; Richardson J; Steel A; Moondi P; Young P
    J Med Eng Technol; 2015; 39(5):259-63. PubMed ID: 25970696
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Comparison of bacterial contamination of blood conservation system and stopcock system arterial sampling lines used in critically ill patients.
    Oto J; Nakataki E; Hata M; Tsunano Y; Okuda N; Imanaka H; Nishimura M
    Am J Infect Control; 2012 Aug; 40(6):530-4. PubMed ID: 22054688
    [TBL] [Abstract][Full Text] [Related]  

  • 5. A prospective clinical study to investigate the microbial contamination ofa needleless connector.
    Seymour VM; Dhallu TS; Moss HA; Tebbs SE; Elliot TS
    J Hosp Infect; 2000 Jun; 45(2):165-8. PubMed ID: 10860694
    [TBL] [Abstract][Full Text] [Related]  

  • 6. A prospective clinical trial to evaluate the microbial barrier of a needleless connector.
    Casey AL; Burnell S; Whinn H; Worthington T; Faroqui MH; Elliott TS
    J Hosp Infect; 2007 Mar; 65(3):212-8. PubMed ID: 17241691
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Microbial contamination of arterial infusions used for hemodynamic monitoring: a randomized trial of contamination with sampling through conventional stopcocks versus a novel closed system.
    Crow S; Conrad SA; Chaney-Rowell C; King JW
    Infect Control Hosp Epidemiol; 1989 Dec; 10(12):557-61. PubMed ID: 2614056
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Bloodstream infection related to catheter connections: a prospective trial of two connection systems.
    Esteve F; Pujol M; Limón E; Saballs M; Argerich MJ; Verdaguer R; Mañez R; Ariza X; Gudiol F
    J Hosp Infect; 2007 Sep; 67(1):30-4. PubMed ID: 17719682
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Preventing central venous catheter-associated bloodstream infections: development of an antiseptic barrier cap for needleless connectors.
    Menyhay SZ; Maki DG
    Am J Infect Control; 2008 Dec; 36(10):S174.e1-5. PubMed ID: 19084153
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Bacterial contamination of arterial lines. A prospective study.
    Shinozaki T; Deane RS; Mazuzan JE; Hamel AJ; Hazelton D
    JAMA; 1983 Jan; 249(2):223-5. PubMed ID: 6848808
    [TBL] [Abstract][Full Text] [Related]  

  • 11. The comparison of heparinized insulin syringes and safety-engineered blood gas syringes used in arterial blood gas sampling in the ED setting (randomized controlled study).
    Baskın SB; Oray NÇ; Yanturalı S; Bayram B
    Am J Emerg Med; 2014 May; 32(5):432-7. PubMed ID: 24560392
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Prevention of intravenous bacterial injection from health care provider hands: the importance of catheter design and handling.
    Loftus RW; Patel HM; Huysman BC; Kispert DP; Koff MD; Gallagher JD; Jensen JT; Rowlands J; Reddy S; Dodds TM; Yeager MP; Ruoff KL; Surgenor SD; Brown JR
    Anesth Analg; 2012 Nov; 115(5):1109-19. PubMed ID: 23051883
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Effects of syringe material and needle size on the minimum plunger-displacement pressure of arterial blood gas syringes.
    Ansel GM; Douce FH
    Respir Care; 1982 Feb; 27(2):147-51. PubMed ID: 10315159
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Experimental study on the safety of a new connecting device.
    Trautmann M; Moosbauer S; Schmitz FJ; Lepper PM
    Am J Infect Control; 2004 Aug; 32(5):296-300. PubMed ID: 15292896
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Always flush the sampling port before flushing the arterial cannula in pediatric patients.
    Weiss M; Fischer JE; Neff T; Hug MI; Baenziger O
    Acta Anaesthesiol Scand; 2001 Jul; 45(6):729-33. PubMed ID: 11421831
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Two serial check valves can prevent cross-contamination through intravenous tubing during total intravenous anesthesia.
    Radke OC; Werth K; Borg-von-Zepelin M; Saur P; Apfel CC
    Anesth Analg; 2010 Oct; 111(4):925-8. PubMed ID: 20810677
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Resistance to the migration of microorganisms of a needle-free disinfectable connector.
    Yébenes JC; Martnez R; Serra-Prat M; Sauca G; Capdevila JA; Balanzó X; Palomar M
    Am J Infect Control; 2003 Dec; 31(8):462-4. PubMed ID: 14647107
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Closed arterial lab sampling devices: a study of compliance and best practice.
    Benedict A; Mayer A; Craven H
    Br J Nurs; 2017 Jul; 26(14):S24-S29. PubMed ID: 28745959
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Catheter-drawn blood cultures: is withdrawing the heparin lock beneficial?
    Everts R; Harding H
    Pathology; 2004 Apr; 36(2):170-3. PubMed ID: 15203754
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Efficacy of three different valve systems of needle-free closed connectors in avoiding access of microorganisms to endovascular catheters after incorrect handling.
    Yébenes JC; Delgado M; Sauca G; Serra-Prat M; Solsona M; Almirall J; Capdevila JA; Balanzó X
    Crit Care Med; 2008 Sep; 36(9):2558-61. PubMed ID: 18679126
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.