297 related articles for article (PubMed ID: 25315657)
1. Ultrasound image edge detection based on a novel multiplicative gradient and Canny operator.
Zheng Y; Zhou Y; Zhou H; Gong X
Ultrason Imaging; 2015 Jul; 37(3):238-50. PubMed ID: 25315657
[TBL] [Abstract][Full Text] [Related]
2. Implementing a Parallel Image Edge Detection Algorithm Based on the Otsu-Canny Operator on the Hadoop Platform.
Cao J; Chen L; Wang M; Tian Y
Comput Intell Neurosci; 2018; 2018():3598284. PubMed ID: 29861711
[TBL] [Abstract][Full Text] [Related]
3. Rayleigh-maximum-likelihood bilateral filter for ultrasound image enhancement.
Li H; Wu J; Miao A; Yu P; Chen J; Zhang Y
Biomed Eng Online; 2017 Apr; 16(1):46. PubMed ID: 28412952
[TBL] [Abstract][Full Text] [Related]
4. Bas-relief map using texture analysis with application to live enhancement of ultrasound images.
Du H; Ma R; Wang X; Zhang J; Fang J
Ultrasound Med Biol; 2015 May; 41(5):1446-60. PubMed ID: 25641600
[TBL] [Abstract][Full Text] [Related]
5. Compressed sensing based CT reconstruction algorithm combined with modified Canny edge detection.
Hsieh CJ; Huang TK; Hsieh TH; Chen GH; Shih KL; Chen ZY; Chen JC; Chu WC
Phys Med Biol; 2018 Jul; 63(15):155011. PubMed ID: 29938686
[TBL] [Abstract][Full Text] [Related]
6. [The frequency features and application of edge detection differential operators in medical image].
Wu J; Ding H; Wang G; Ding H; Zhou Y
Sheng Wu Yi Xue Gong Cheng Xue Za Zhi; 2005 Feb; 22(1):82-5. PubMed ID: 15762122
[TBL] [Abstract][Full Text] [Related]
7. Speckle noise reduction in ultrasound biomedical B-scan images using discrete topological derivative.
Damodaran N; Ramamurthy S; Velusamy S; Manickam GK
Ultrasound Med Biol; 2012 Feb; 38(2):276-86. PubMed ID: 22230135
[TBL] [Abstract][Full Text] [Related]
8. A novel edge detection in medical images by fusing of multi-model from different spatial structure clues.
Jia X; Huang H; Wang R
Biomed Mater Eng; 2014; 24(1):1289-98. PubMed ID: 24212024
[TBL] [Abstract][Full Text] [Related]
9. SRBF: Speckle reducing bilateral filtering.
Balocco S; Gatta C; Pujol O; Mauri J; Radeva P
Ultrasound Med Biol; 2010 Aug; 36(8):1353-63. PubMed ID: 20691924
[TBL] [Abstract][Full Text] [Related]
10. A hybrid algorithm for speckle noise reduction of ultrasound images.
Singh K; Ranade SK; Singh C
Comput Methods Programs Biomed; 2017 Sep; 148():55-69. PubMed ID: 28774439
[TBL] [Abstract][Full Text] [Related]
11. Noise-resilient edge detection algorithm for brain MRI images.
Agaian S; Almuntashri A
Annu Int Conf IEEE Eng Med Biol Soc; 2009; 2009():3689-92. PubMed ID: 19965004
[TBL] [Abstract][Full Text] [Related]
12. Alternating minimization algorithm for speckle reduction with a shifting technique.
Woo H; Yun S
IEEE Trans Image Process; 2012 Apr; 21(4):1701-14. PubMed ID: 22106149
[TBL] [Abstract][Full Text] [Related]
13. [An improved morphological edge detection algorithm of medical image based on multi-structure element].
Luo X; Liu T; Peng C; Wen L
Sheng Wu Yi Xue Gong Cheng Xue Za Zhi; 2009 Feb; 26(1):177-80, 183. PubMed ID: 19334580
[TBL] [Abstract][Full Text] [Related]
14. Nonlinear multiscale wavelet diffusion for speckle suppression and edge enhancement in ultrasound images.
Yue Y; Croitoru MM; Bidani A; Zwischenberger JB; Clark JW
IEEE Trans Med Imaging; 2006 Mar; 25(3):297-311. PubMed ID: 16524086
[TBL] [Abstract][Full Text] [Related]
15. Boundary detection in medical images using edge following algorithm based on intensity gradient and texture gradient features.
Somkantha K; Theera-Umpon N; Auephanwiriyakul S
IEEE Trans Biomed Eng; 2011 Mar; 58(3):567-73. PubMed ID: 21062676
[TBL] [Abstract][Full Text] [Related]
16. Edge detection in medical images using a genetic algorithm.
Gudmundsson M; El-Kwae EA; Kabuka MR
IEEE Trans Med Imaging; 1998 Jun; 17(3):469-74. PubMed ID: 9735910
[TBL] [Abstract][Full Text] [Related]
17. Multiscale toggle contrast operator-based mineral image enhancement.
Bai X; Zhou F
J Microsc; 2011 Aug; 243(2):141-53. PubMed ID: 21288238
[TBL] [Abstract][Full Text] [Related]
18. Demosaicing of color filter array captured images using gradient edge detection masks and adaptive heterogeneity-projection.
Chung KL; Yang WJ; Yan WM; Wang CC
IEEE Trans Image Process; 2008 Dec; 17(12):2356-67. PubMed ID: 19004708
[TBL] [Abstract][Full Text] [Related]
19. Boundary enhancement and speckle reduction for ultrasound images via salient structure extraction.
Xie J; Jiang Y; Tsui HT; Heng PA
IEEE Trans Biomed Eng; 2006 Nov; 53(11):2300-9. PubMed ID: 17073336
[TBL] [Abstract][Full Text] [Related]
20. Automatic craniofacial structure detection on cephalometric images.
Mondal T; Jain A; Sardana HK
IEEE Trans Image Process; 2011 Sep; 20(9):2606-14. PubMed ID: 21435982
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]