These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

140 related articles for article (PubMed ID: 25316377)

  • 21. Comparison of polyethylene wear associated with cobalt-chromium and zirconia heads after total hip replacement. A prospective, randomized study.
    Kim YH
    J Bone Joint Surg Am; 2005 Aug; 87(8):1769-76. PubMed ID: 16085617
    [TBL] [Abstract][Full Text] [Related]  

  • 22. The Biotribology of PEEK-on-HXLPE Bearings Is Comparable to Traditional Bearings on a Multidirectional Pin-on-disk Tester.
    Baykal D; Siskey RS; Underwood RJ; Briscoe A; Kurtz SM
    Clin Orthop Relat Res; 2016 Nov; 474(11):2384-2393. PubMed ID: 27457625
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Surface roughness of retrieved CoCrMo alloy femoral components from PCA artificial total knee joints.
    Que L; Topoleski LD; Parks NL
    J Biomed Mater Res; 2000; 53(1):111-8. PubMed ID: 10634960
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Knee wear measured in retrievals: a polished tray reduces insert wear.
    Berry DJ; Currier JH; Mayor MB; Collier JP
    Clin Orthop Relat Res; 2012 Jul; 470(7):1860-8. PubMed ID: 22314963
    [TBL] [Abstract][Full Text] [Related]  

  • 25. A hip joint simulator study using new and physiologically scratched femoral heads with ultra-high molecular weight polyethylene acetabular cups.
    Barbour PS; Stone MH; Fisher J
    Proc Inst Mech Eng H; 2000; 214(6):569-76. PubMed ID: 11201404
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Oxidised zirconium
    Anderson FL; Koch CN; Elpers ME; Wright TM; Haas SB; Heyse TJ
    Bone Joint J; 2017 Jun; 99-B(6):793-798. PubMed ID: 28566399
    [TBL] [Abstract][Full Text] [Related]  

  • 27. A comparison between gravimetric and volumetric techniques of wear measurement of UHMWPE acetabular cups against zirconia and cobalt-chromium-molybdenum femoral heads in a hip simulator.
    Smith SL; Unsworth A
    Proc Inst Mech Eng H; 1999; 213(6):475-83. PubMed ID: 10635696
    [TBL] [Abstract][Full Text] [Related]  

  • 28. PEEK-OPTIMA
    Cowie RM; Briscoe A; Fisher J; Jennings LM
    Proc Inst Mech Eng H; 2016 Nov; 230(11):1008-1015. PubMed ID: 27637723
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Five-year comparison of wear using oxidised zirconium and cobalt-chrome femoral heads in total hip arthroplasty: a multicentre randomised controlled trial.
    Jassim SS; Patel S; Wardle N; Tahmassebi J; Middleton R; Shardlow DL; Stephen A; Hutchinson J; Haddad FS
    Bone Joint J; 2015 Jul; 97-B(7):883-9. PubMed ID: 26130341
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Wear predictions for UHMWPE material with various surface properties used on the femoral component in total knee arthroplasty: a computational simulation study.
    Kang KT; Son J; Kim HJ; Baek C; Kwon OR; Koh YG
    J Mater Sci Mater Med; 2017 Jul; 28(7):105. PubMed ID: 28534290
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Not all zirconia femoral heads degrade in vivo.
    Roy ME; Whiteside LA; Katerberg BJ; Steiger JA; Nayfeh T
    Clin Orthop Relat Res; 2007 Dec; 465():220-6. PubMed ID: 17828030
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Component wear of total knee prostheses using Ti-6A1-4V, titanium nitride coated Ti-6A1-4V, and cobalt-chromium-molybdenum femoral components.
    Peterson CD; Hillberry BM; Heck DA
    J Biomed Mater Res; 1988 Oct; 22(10):887-903. PubMed ID: 3220840
    [TBL] [Abstract][Full Text] [Related]  

  • 33. [Clinical evaluation of the ceramic femoral component used for reconstruction of total knee replacement].
    Vavrík P; Landor I; Denk F
    Acta Chir Orthop Traumatol Cech; 2008 Dec; 75(6):436-42. PubMed ID: 19150000
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Comparison of wear of ultra-high molecular weight polyethylene acetabular cups against surface-engineered femoral heads.
    Galvin A; Brockett C; Williams S; Hatto P; Burton A; Isaac G; Stone M; Ingham E; Fisher J
    Proc Inst Mech Eng H; 2008 Oct; 222(7):1073-80. PubMed ID: 19024155
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Is there a difference in total knee arthroplasty risk of revision in highly crosslinked versus conventional polyethylene?
    Paxton EW; Inacio MC; Kurtz S; Love R; Cafri G; Namba RS
    Clin Orthop Relat Res; 2015 Mar; 473(3):999-1008. PubMed ID: 25567357
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Oxidized Zirconium Components Maintain a Smooth Articular Surface Except Following Hip Dislocation.
    Bonnheim NB; Van Citters DW; Ries MD; Pruitt LA
    J Arthroplasty; 2021 Apr; 36(4):1437-1444. PubMed ID: 33246784
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Comparison of the Genesis II total knee replacement with oxidised zirconium and cobalt-chromium femoral components in the same patients: a prospective, double-blind, randomised controlled study.
    Kim YH; Park JW; Kim JS
    J Bone Joint Surg Br; 2012 Sep; 94(9):1221-7. PubMed ID: 22933494
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Total Articular Knee Replacement Using Polyurethane.
    Pritchett JW
    J Knee Surg; 2020 Mar; 33(3):242-246. PubMed ID: 30716773
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Prediction of scratch resistance of cobalt chromium alloy bearing surface, articulating against ultra-high molecular weight polyethylene, due to third-body wear particles.
    Mirghany M; Jin ZM
    Proc Inst Mech Eng H; 2004; 218(1):41-50. PubMed ID: 14982345
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Ten-year follow-up study of three alternative bearing surfaces used in total hip arthroplasty in young patients: a prospective randomised controlled trial.
    Atrey A; Ward SE; Khoshbin A; Hussain N; Bogoch E; Schemitsch EH; Waddell JP
    Bone Joint J; 2017 Dec; 99-B(12):1590-1595. PubMed ID: 29212681
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 7.