BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

357 related articles for article (PubMed ID: 25322958)

  • 1. Complex EVAR for abdominal aorto-iliac aneurysm (AAIA) is associated with high rate of endoleak and less aortic sac shrinkage compared to conventional EVAR for AAA.
    Blair R; Collins A; Harkin DW
    Ir J Med Sci; 2015 Dec; 184(4):871-5. PubMed ID: 25322958
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Predisposing Factors for Migration of the Iliac Limb and Reintervention after Endovascular Abdominal Aortic Aneurysm Repair.
    Wang Y; Li C; Xin H; Li J; Wang H
    Ann Vasc Surg; 2019 Aug; 59():91-101. PubMed ID: 31009727
    [TBL] [Abstract][Full Text] [Related]  

  • 3. External iliac artery extension causes greater aneurysm sac regression than the bell-bottom technique or iliac branch endoprosthesis for repair of concomitant infrarenal aortic and iliac artery aneurysm.
    Bahroloomi D; Qato K; Nguyen N; Schreiber-Gregory D; Conway AM; Giangola G; Carroccio A
    J Vasc Surg; 2022 Jul; 76(1):132-140. PubMed ID: 34998943
    [TBL] [Abstract][Full Text] [Related]  

  • 4. A morphovolumetric analysis of aneurysm sac evolution after elective endovascular abdominal aortic repair.
    Franchin M; Serafini M; Tadiello M; Fontana F; Rivolta N; Venturini M; Curti M; Bush RL; Dorigo W; Piacentino F; Tozzi M; Piffaretti G
    J Vasc Surg; 2021 Oct; 74(4):1222-1231.e2. PubMed ID: 33864827
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Long Term Outcomes of Endovascular Aortic Repair in Patients With Abdominal Aortic Aneurysm and Ectatic Common Iliac Arteries.
    Gibello L; Varetto G; Ruffino MA; Peretti T; Frola E; Cieri E; Parlani G; Ripepi M; Rispoli P; Verzini F
    Eur J Vasc Endovasc Surg; 2020 Sep; 60(3):356-364. PubMed ID: 32709466
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Role of type II endoleak in sac regression after endovascular repair of infrarenal abdominal aortic aneurysms.
    Kray J; Kirk S; Franko J; Chew DK
    J Vasc Surg; 2015 Apr; 61(4):869-74. PubMed ID: 25601501
    [TBL] [Abstract][Full Text] [Related]  

  • 7. The role of the inferior mesenteric artery in predicting secondary intervention for type II endoleak following endovascular aneurysm repair.
    Chew DK; Dong S; Schroeder AC; Hsu HW; Franko J
    J Vasc Surg; 2019 Nov; 70(5):1463-1468. PubMed ID: 31327603
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Multicenter Mid-term Results After Endovascular Aortic Aneurysm Repair with the Incraft® Device.
    Georgiadis GS; Chatzigakis PK; Kouvelos G; Argyriou C; Kopadis GC; Georgakarakos EI; Matsagkas M
    Ann Vasc Surg; 2021 Apr; 72():464-478. PubMed ID: 32946999
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Midterm Outcomes of Endovascular Abdominal Aortic Aneurysm Repair with Prevention of type 2 Endoleak by Intraoperative Aortic Side Branch Coil Embolization.
    Aoki A; Maruta K; Omoto T; Masuda T
    Ann Vasc Surg; 2022 Jan; 78():180-189. PubMed ID: 34537351
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Two-year outcome of the Endurant stent graft for endovascular abdominal aortic repair in Japanese patients: incidence of endoleak and aneurysm sac shrinkage.
    Nishibe T; Iwahashi T; Kamiya K; Toguchi K; Maruno K; Fujiyoshi T; Muromachi Y; Suzuki S; Koizumi J; Ogino H
    Int Angiol; 2017 Jun; 36(3):237-242. PubMed ID: 27575330
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Fenestrated and Branched Thoraco-abdominal Endografting after Previous Open Abdominal Aortic Repair.
    Gallitto E; Sobocinski J; Mascoli C; Pini R; Fenelli C; Faggioli G; Haulon S; Gargiulo M
    Eur J Vasc Endovasc Surg; 2020 Dec; 60(6):843-852. PubMed ID: 32855033
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Reducing aneurysm sac growth and secondary interventions following endovascular abdominal aortic aneurysm repair by preemptive coil embolization of the inferior mesenteric artery and lumbar arteries.
    Chew DK; Schmelter RA; Tran MT; Franko J
    J Vasc Surg; 2024 Mar; 79(3):532-539. PubMed ID: 38008267
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Is internal iliac artery embolization essential prior to endovascular repair of aortoiliac aneurysms?
    Bharwani N; Raja J; Choke E; Belli AM; Thompson MM; Morgan RA; Munneke G
    Cardiovasc Intervent Radiol; 2008; 31(3):504-8. PubMed ID: 18214596
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Changes in Apposition of Endograft Limbs in the Iliac Arteries After Endovascular Aneurysm Repair: Determination With New Computed Tomography-Applied Software.
    Goudeketting SR; Schuurmann RCL; Slump CH; de Vries JPM
    J Endovasc Ther; 2019 Dec; 26(6):843-852. PubMed ID: 31402731
    [No Abstract]   [Full Text] [Related]  

  • 15. EVAR with Flared Iliac Limbs has a High Risk of Late Type 1b Endoleak.
    Gray D; Shahverdyan R; Reifferscheid V; Gawenda M; Brunkwall JS
    Eur J Vasc Endovasc Surg; 2017 Aug; 54(2):170-176. PubMed ID: 28687427
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Midterm outcomes and evolution of gutter area after endovascular aneurysm repair with the chimney graft procedure.
    de Beaufort HWL; Cellitti E; de Ruiter QMB; Conti M; Trimarchi S; Moll FL; Hazenberg CEVB; van Herwaarden JA
    J Vasc Surg; 2018 Jan; 67(1):104-112.e3. PubMed ID: 28668275
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Predictors of abdominal aortic aneurysm sac enlargement after endovascular repair.
    Schanzer A; Greenberg RK; Hevelone N; Robinson WP; Eslami MH; Goldberg RJ; Messina L
    Circulation; 2011 Jun; 123(24):2848-55. PubMed ID: 21478500
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Planning and Endograft Related Variables Predisposing to Late Distal Type I Endoleaks.
    Mascoli C; Faggioli G; Gallitto E; Longhi M; Abualhin M; Pini R; Massoni CB; Freyrie A; Stella A; Gargiulo M
    Eur J Vasc Endovasc Surg; 2019 Sep; 58(3):334-342. PubMed ID: 31358363
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Comparison of midterm results of endovascular aneurysm repair for ruptured and elective abdominal aortic aneurysms.
    Oliveira-Pinto J; Soares-Ferreira R; Oliveira NFG; Bastos Gonçalves FM; Hoeks S; Van Rijn MJ; Raa ST; Mansilha A; Verhagen HJM
    J Vasc Surg; 2020 May; 71(5):1554-1563.e1. PubMed ID: 31677942
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Long-term outcomes of the Ovation Stent Graft System investigational device exemption trial for endovascular abdominal aortic aneurysm repair.
    Barleben A; Mathlouthi A; Mehta M; Nolte T; Valdes F; Malas MB;
    J Vasc Surg; 2020 Nov; 72(5):1667-1673.e1. PubMed ID: 32249041
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 18.